Uniform field loop-gap resonator and rectangular TE U02 for aqueous sample EPR at 94 GHz

Journal of Magnetic Resonance - Tập 282 - Trang 129-135 - 2017
Jason W. Sidabras1,2, Tadeusz Sarna3, Richard R. Mett2,4, James S. Hyde2
1Max Planck for Chemical Energy Conversion, Department of Biophysical Chemistry, Mülheim an der Ruhr 45468, Germany
2Medical College of Wisconsin, Department of Biophysics, Milwaukee, WI 53226-0509, United States
3Department of Biophysics, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Kraków, Poland
4Milwaukee School of Engineering, Department of Physics and Chemistry, Milwaukee, WI 53202-3109, United States

Tài liệu tham khảo

Mett, 2001, Axially uniform resonant cavity modes for potential use in electron paramagnetic resonance spectroscopy, Rev. Sci. Instrum., 72, 4188, 10.1063/1.1405796 Anderson, 2002, Cavities with axially uniform fields for use in electron paramagnetic resonance. II. Free space generalization, Rev. Sci. Instrum., 73, 3027, 10.1063/1.1491032 Hyde, 2002, Cavities with axially uniform fields for use in electron paramagnetic resonance. III. Re-entrant geometries, Rev. Sci. Instrum., 73, 4003, 10.1063/1.1510549 J.S. Hyde, R.R. Mett, W. Froncisz, J.R. Anderson, Cavity Resonator for Electron Paramagnetic Resonance Spectroscopy having Axially Uniform Field, US Patent 6,828,789, December 7, 2004. Mett, 2007, Uniform radio fields in loop-gap resonators for EPR spectroscopy, Appl. Magn. Reson., 31, 573, 10.1007/BF03166603 Sidabras, 2007, Multipurpose EPR loop-gap resonator and cylindrical TE011 cavity for aqueous samples at 94GHz, Rev. Sci. Instrum., 78, 034701, 10.1063/1.2709746 Hyde, 2007, Microwave frequency modulation in CW EPR at W-band using a loop-gap resonator, J. Magn. Reson., 185, 259, 10.1016/j.jmr.2007.01.002 Froncisz, 2008, Saturation recovery EPR and ELDOR at W-band for spin labels, J. Magn. Reson., 193, 297, 10.1016/j.jmr.2008.05.008 Sidabras, 2017, Axially uniform magnetic field-modulation excitation for electron paramagnetic resonance in rectangular and cylindrical cavities by slot cutting, J. Magn. Reson., 274, 115, 10.1016/j.jmr.2016.11.014 Eaton, 2010 R.C. Rempel, C.E. Ward, R.T. Sullivan, M.W.St. Clair, H.E. Weaver, Gyromagnetic Resonance Method and Apparatus, US Patent 3,122,703, December 21, 1959. Schweiger, 2001 Tait, 2017, Endor with band-selective shaped inversion pulses, J. Magn. Res., 277, 36, 10.1016/j.jmr.2017.02.007 Mainali, 2014, Spin-label W-band EPR with seven-loop–six-gap resonator: application to lens membranes derived from eyes of a single donor, Appl. Magn. Reson., 45, 1343, 10.1007/s00723-014-0578-7 Strangeway, 2017, Broadband W-band rapid frequency sweep considerations for fourier transform EPR, Cell Biochem. Biophys., 10.1007/s12013-017-0804-7 Hyde, 1989, Loop-gap resonators, 277 Hyde, 2011, Resonators for multifrequency EPR of spin labels, 244 Ramo, 1984 Mett, 2009, Coupling of waveguide and resonator by inductive and capacitive irises for EPR spectroscopy, Appl. Magn. Reson., 35, 285, 10.1007/s00723-008-0162-0 Mett, 2005, Microwave leakage from field modulation slots in TE011 electron paramagnetic resonance cavities, Rev. Sci. Instrum., 76, 014702, 10.1063/1.1823748 Sato, 2003, Electron spin resonance of ascorbyl (vitamin C) radicals in synthetic CaCO3 by UV irradiation, J. Appl. Phys., 42, 428, 10.1143/JJAP.42.428 Sarna, 1991, Photoinduced electron transfer reactions of Rose bengal and selected electron donors, J. Photochem. Photobiol. A: Chem., 60, 295, 10.1016/1010-6030(91)90032-O Lambert, 1990, Rose bengal radicals and their reactivity, J. Chem. Soc. Faraday Trans., 86, 3879, 10.1039/ft9908603879