Ultrasound Therapy Equipment — Does it Perform?
Tài liệu tham khảo
Allen, 1978, ‘Performance of ultrasonic therapy instruments’, Physiotherapy, 64, 174
British Standards Institution, 1985
Chartered Society of Physiotherapy, 1990, ‘Guide lines for the safe use of ultrasound physiotherapy equipment’, Physiotherapy, 76, 683, 10.1016/S0031-9406(10)63115-X
Dudley, 1995
Fyfe, 1982, ‘The importance of measurement of effective transducer radiating area in the testing and calibration of ‘‘therapeutic’’ ultrasonic instruments’, Health Physics, 43, 377, 10.1097/00004032-198209000-00007
Hekkenberg, 1986, ‘Evaluation of ultrasound therapy devices’, Physiotherapy, 72, 390
Hekkenberg, 1994, ‘Development of standard measurement methods for essential properties of ultrasonic therapy equipment’, Ultrasound in Medicine and Biology, 20, 83, 10.1016/0301-5629(94)90020-5
International Electrotechnical Commission, 1963
International Electrotechnical Commission, 1984
International Electrotechnical Commission, 1992
International Electrotechnical Commission, 1995
Institute of Physical Sciences in Medicine, 1988
King’s Fund, 1995
Kossoff, 1962, ‘Calibration of ultrasonic therapeutic equipment’, Acustica, 12, 84
Lunt, 1979, ‘A simple radiation balance for measuring ultrasonic power’, Journal of Medical Engineering Technology, 3, 194, 10.3109/03091907909161676
Perkins, 1989, ‘A versatile force balance for ultrasound power measurement’, Physics in Medicine and Biology, 34, 1645, 10.1088/0031-9155/34/11/011
Preston, 1986, ‘Measurement and characterisation of the acoustic output of medical ultrasonic equipment, Part 1’, Medical and Biological Engineering and Computing, 24, 113, 10.1007/BF02443923
Preston, 1986, ‘Measurement and characterisation of the acoustic output of medical ultrasonic equipment, Part 2’, Medical and Biological Engineering and Computing, 24, 225, 10.1007/BF02441617
Pye, 1994, ‘The performance of ultrasound therapy machines in Lothian Region, 1992, Ultrasound in Medicine and Biology, 20, 347, 10.1016/0301-5629(94)90003-5
Pye, 1994, ‘A simple calorimeter for monitoring the power output of ultrasound therapy machines’, Physiotherapy, 80, 219, 10.1016/S0031-9406(10)61301-6
Repacholi, 1979, ‘Using surveys of ultrasound therapy devices to draft performance standards’, Health Physics, 36, 679, 10.1097/00004032-197906000-00003
Shotton, 1980, ‘A tethered float radiometer for measuring the output power from ultrasonic therapy equipment’, Ultrasound in Medicine and Biology, 6, 131, 10.1016/0301-5629(80)90041-1
Snow, 1982, ‘Ultrasound therapy units in Manitoba and Northwestern Ontario: performance evaluation’, Physiotherapy Canada, 34, 185
Stewart, 1974, ‘Survey of the use and performance of ultrasonic therapy equipment in Pinellas County, Florida’, Physical Therapy, 54, 707, 10.1093/ptj/54.7.707
Torr, 1977, ‘A constant flow calorimeter for the measurement of acoustic power at megahertz frequencies’, Physics in Medicine and Biology, 22, 444, 10.1088/0031-9155/22/3/005