Ultrasonic method for measuring water holdup of low velocity and high-water-cut oil-water two-phase flow

Applied Geophysics - Tập 13 - Trang 179-193 - 2016
An Zhao1, Yun-Feng Han1, Ying-Yu Ren1, Lu-Sheng Zhai1, Ning-De in1
1School of Electrical Engineering and Automation, Tianjin University, Tianjin, China

Tóm tắt

Oil reservoirs with low permeability and porosity that are in the middle and late exploitation periods in China’s onshore oil fields are mostly in the high-water-cut production stage. This stage is associated with severely non-uniform local-velocity flow profiles and dispersed-phase concentration (of oil droplets) in oil-water two-phase flow, which makes it difficult to measure water holdup in oil wells. In this study, we use an ultrasonic method based on a transmission-type sensor in oil-water two-phase flow to measure water holdup in low-velocity and high water-cut conditions. First, we optimize the excitation frequency of the ultrasonic sensor by calculating the sensitivity of the ultrasonic field using the finite element method for multiphysics coupling. Then we calculate the change trend of sound pressure level attenuation ratio with the increase in oil holdup to verify the feasibility of the employed diameter for the ultrasonic sensor. Based on the results, we then investigate the effects of oil-droplet diameter and distribution on the ultrasonic field. To further understand the measurement characteristics of the ultrasonic sensor, we perform a flow loop test on vertical upward oil-water two-phase flow and measure the responses of the optimized ultrasonic sensor. The results show that the ultrasonic sensor yields poor resolution for a dispersed oil slug in water flow (D OS/W flow), but the resolution is favorable for dispersed oil in water flow (D O/W flow) and very fine dispersed oil in water flow (VFD O/W flow). This research demonstrates the potential application of a pulsed-transmission ultrasonic method for measuring the fraction of individual components in oil-water two-phase flow with a low mixture velocity and high water cut.

Tài liệu tham khảo

Al-Lababidi, S., Addali, A., Yeung, H., Mba, D., and Khan, F., 2009, Gas void fraction measurement in two-phase gas/liquid slug flow using acoustic emission technology: Journal of Vibration & Acoustics, 131(6), 1747–1750. Carvalho, R. D. M., Venturini, O. J., Tanahashi, E. I., Neves, Jr. F., and Franca, F. A., 2009, Application of the ultrasonic technique and high-speed filming for the study of the structure of air-water bubbly flows: Experimental Thermal & Fluidence, 33(7), 1065–1086. Chaudhuri, A., Osterhoudt, C. F., and Sinha, D. N., 2012, An algorithm for determining volume fractions in twophase liquid flows by measuring sound speed: Journal of Fluids Engineering, 134(10), 101301. Chaudhuri, A., Sinha, D. N., Zalte, A., Pereyra, E., Webb, C., and Gonzalez, M., 2014, Mass fraction measurements in controlled oil-water flows using noninvasive ultrasonic sensors: Journal of Fluids Engineering, 136(3), 031304. Cong, J. S., Wang, X. M., Chen, D. H., Xu, D. L., Che, C. X., and Ma, S. L., 2008, Gas detection in a gas-liquid flow using an acoustic resonance spectroscopy method: Chinese Journal of Geophysics, 51(1), 280–284. Dong, X., Tan, C., Yuan, Y., and Dong, F., 2015, Oil-water two-phase flow velocity measurement with continuous wave ultrasound Doppler: Chemical Engineering Science, 135, 155–165. Hall, L., 1948, The origin of ultrasonic absorption in water: Physical Review, 73(7), 775–781. Kirchhoff, G., 1868, Ueber den Einfluss der Wärmeleitung in einem Gase auf die Schallbewegung: Annalen der Physik, 210(6), 177–193. Liu, J. C., Liu, X. B., Zhuang, H. J., and Yuan, Z. H., 2005, Experiments of ultrasonic holdup measurement for non packer water oil two phase flow: Well Logging Technology (in Chinese), 29(5), 453–455. Meng, G., Jaworski, A. J., Dyakowski, T., Hale, J. M., and White, N. M., 2005, Design and testing of a thick-film dual-modality sensor for composition measurements in heterogeneous mixtures: Measurement Science & Technology, 16(4), 942–954. Meng, G., Jaworski, A. J., and White, N. M., 2006, Composition measurements of crude oil and process water emulsions using thick-film ultrasonic transducers: Chemical Engineering & Processing Process Intensification, 45(5), 383–391. Meribout, M., Al-Rawahi, N., Al-Naamany, A., Al-Bimani, A., Al-Busaidi, K., and Meribout, A., 2010, Integration of impedance measurements with acoustic measurements for accurate two phase flow metering in case of high water-cut: Flow Measurement & Instrumentation, 21(1), 8–19. Morriss, S. L., and Hill, A. D., 1993, Ultrasonic imaging and velocimetry in two-phase pipe flow: Journal of Energy Resources Technology, 115(2), 108–116. Murakawa, H., Kikura, H., and Aritomi, M., 2005, Application of ultrasonic doppler method for bubbly flow measurement using two ultrasonic frequencies: Experimental Thermal & Fluid Science, 29(7), 843–850. Murakawa, H., Kikura, H., and Aritomi, M., 2008, Application of ultrasonic multi-wave method for twophase bubbly and slug flows: Flow Measurement & Instrumentation, 19(3–4), 205–213. Murai, Y., Tasaka, Y., Nambu, Y., Takeda, Y., and Gonzalez-A, S, R., 2010, Ultrasonic detection of moving interfaces in gas-liquid two-phase flow: Flow Measurement & Instrumentation, 21(3), 356–366. Ohkawa, W. M., Maezawa, A., and Uchida, S., 1997, Flow structure and phase distributions in a slurry bubble column: Chemical Engineering Science, 52(21–22), 3941–3947. Roosnek, N., 2000, Novel digital signal processing techniques for ultrasonic gas flow measurements: Flow Measurement & Instrumentation, 11(2), 89–99. Supardan, M. D., Masuda, Y., Maezawa, A., and Uchida, S., 2007, The investigation of gas holdup distribution in a two-phase bubble column using ultrasonic computed tomography: Chemical Engineering Journal, 130(2–3), 125–133. Su, M. X., Xue, M. H., Cai, X. S., Shang, Z. T., and Xu, F., 2008, Particle size characterization by ultrasonic attenuation spectra: Particuology, 6(4), 276–281. Su, M. X., Cai, X. S., Xue, M. H., Dong, L. L., and Xu, F., 2009, Particle sizing in dense two-phase droplet systems by ultrasonic attenuation and velocity spectra: Science in China, 52(6), 1502–1510. Wada, S., Kikura, H., and Aritomi, M., 2006, Pattern recognition and signal processing of ultrasonic echo signal on two-phase flow: Flow Measurement & Instrumentation, 17(4), 207–224. Xu, L. A., Leonard, D., and Green, R. G., 1985, A pulsed ultrasound transducer system for two component flow: Journal of Physics E: Scientific Instruments, 18(7), 609–613. Xu, L. J., Han, Y. T., Xu, L. A., and Yang, J. S., 1997, Application of ultrasonic tomography to monitoring gas/liquid flow: Chemical Engineering Science, 52(13), 2171–2183. Xu, X. M., 2003, Fundamentals of Acoustics: Science Press, Beijing, 236–256 (in Chinese). Zhai, L. S., Jin, N. D., Gao, Z. K., Wang, Z. Y., and Li, D. M., 2013, The ultrasonic measurement of high water volume fraction in dispersed oil-in-water flows: Chemical Engineering Science, 94, 271–283. Zheng, Y., and Zhang, Q. K., 2004, Simultaneous measurement of gas and solid holdups in multiphase systems using ultrasonic technique: Chemical Engineering Science, 59(17), 3505–3514.