Transjugular liver biopsy using ultrasonographic guidance for jugular vein puncture and an automated device for hepatic tissue sampling: a retrospective analysis of 200 consecutive cases

Abdominal Imaging - Tập 33 - Trang 627-632 - 2008
Philippe Soyer1,2, Yann Fargeaudou1, Mourad Boudiaf1, Roland Rymer1,2
1Department of Abdominal Imaging, Hôpital Lariboisière-AP-HP-GHU-Nord, Paris, France
2University Paris 7, Paris, France

Tóm tắt

We retrospectively evaluated the value of the combination of ultrasonographic guidance for jugular vein puncture and an automated biopsy device for transjugular liver biopsy. Transjugular liver biopsy was performed with ultrasonographic guidance for right internal jugular vein puncture and an automated device for hepatic tissue sampling (Quick-Core®) in 200 consecutive patients in whom percutaneous transhepatic biopsy was contraindicated. Histopathologic specimens were reviewed for adequacy and complications related to the procedure were analyzed. Biopsies were technically successful in 198 of 200 (99%) patients. The two cases of technical failure were due to an acute angle between right hepatic vein and inferior vena cava (1%). Adequate gross hepatic tissue specimens (mean length, 11. 0 mm ± 5.3; range, 5.0–20.0 mm) were obtained in 198 (99%) patients, allowing definitive histological diagnosis in 196 of 198 patients, for an overall success rate of 98%. Neither cases of inadvertent injury of the carotid artery nor life-threatening intraperitoneal bleeding were observed. Minor complications were noted in 24/200 (12%) patients. The combination of ultrasonographic guidance for jugular vein puncture and an automated biopsy device for tissue sampling is recommended for transjugular liver biopsy as it results in a safe, well-tolerated, and efficient technique.

Tài liệu tham khảo

Zamcheck N, Klausenstock O (1953) Medical progress: liver biopsy-the risk of needle biopsy. N Engl J Med 249:1062–1069 Velt PM, Choy OG, Shimkin PM, et al. (1984) Transjugular liver biopsy in high-risk patients with hepatic disease. Radiology 153:91–93 Rösch J, Lakin PC, Antonovic R, et al. (1973) Transjugular approach to liver biopsy and transhepatic cholangiography. N Engl J Med 289:227–231 Zins M, Vilgrain V, Gayno S, et al. (1992) US-guided percutaneous liver biopsy with plugging of the needle tract: a prospective study in 72 high-risk patients. Radiology 184:841–845 Colapinto RF, Blendis LM (1983) Liver biopsy through the transjugular approach: modification of instruments. Radiology 148:306 Dotter CT (1964) Catheter biopsy: experimental technique for transvenous liver biopsy. Radiology 82:312–314 Lebrec D, Degott C, Rueff B, et al. (1978) Transvenous (transjugular) liver biopsy. An experience based on 100 biopsies. Am J Dig Dis 23:302–304 Lebrec D, Goldfarb G, Degott C, et al. (1982) Transvenous liver biopsy: an experience based on 1000 hepatic tissue sampling with this procedure. Gastroenterology 83:338–340 Choy OG, Shimkin PM, Link RJ, et al. (1978) The transjugular route as an alternative to direct percutaneous needle biopsy of the liver. Am J Gastroenterol 70:653–656 Little AF, Zajko AB, Orons PD (1996) Transjugular liver biopsy: prospective study in 43 patients with the Quick-Core biopsy needle. J Vasc Interv Radiol 7:127–131 Kardache M, Soyer P, Boudiaf M, et al. (1997) Transjugular liver biopsy with an automated device. Radiology 204:369–372 Gorriz E, Reyes R, Lobrano MB, et al. (1996) Transjugular liver biopsy: a review of 77 biopsies using a spring-propelled cutting needle (biopty gun). Cardiovasc Intervent Radiol 19:442–445 Daumas JL, Sedat J, Thoron JF, et al. (1997) Transjugular needle biopsy of the liver with an automated core biopsy set (letter). AJR 168:280 Soyer P, Lacheheb D, Levesque M (1993) High-resolution sonographic guidance for transjugular liver biopsy. Abdom Imaging 18:360–362 Corr P, Beningfield SJ, Davey N (1992) Transjugular liver biopsy: a review of 200 biopsies. Clin Radiol 45:238–239 Gamble P, Colapinto RD, Stronell RD, et al. (1985) Transjugular liver biopsy: a review of 461 biopsies. Radiology 157:589–593 Choo SW, Do YS, Park KB, et al. (2000) Transjugular liver biopsy: modified Ross transseptal needle versus Quick-Core biopsy needle. Abdom Imaging 25:483–485 Bañares R, Alonso S, Catalina MV, et al. (2001) Randomized controlled trial of aspiration needle versus automated biopsy device for transjugular liver biopsy. J Vasc Interv Radiol 12:583–587 Brenard R, Horsmans Y, Rahier J, et al. (1997) Transjugular liver biopsy: an experience based on 500 procedures. Acta Gastroenterol Belg 60:138–141 Smith TP, Presson TL, Heneghan MA, et al. (2003) Transjugular biopsy of the liver in pediatric and adult patients using an 18-Gauge automated core biopsy needle: a retrospective review of 410 consecutive cases. AJR 180:167–172 Bernardino ME (1990) Automated biopsy devices: significance and safety. Radiology 176:615–616 Liermann D, Kickuth R (2003) CT fluoroscopy-guided abdominal interventions. Abdom Imaging 28:129–134