Tissue damage at anterior capsule edges after continuous curvilinear capsulorhexis, high-frequency capsulotomy, and erbium:YAG laser capsulotomy

Journal of Cataract and Refractive Surgery - Tập 30 - Trang 67-73 - 2004
Gerald Radner1, Michael Amon1, Eva Stifter1, Johannes Nepp1, Gabriele Diendorfer2, Rudolf Mallinger3, Wolfgang Radner1
1Departments of Ophthalmology, Vienna, Austria
2Otorhinolaryngology and Phoniatrics, Vienna, Austria
3Institute of Histology and Embryology, University of Vienna, Vienna, Austria

Tài liệu tham khảo

Gimbel, 1990, Development, advantages, and methods of the continuous circular capsulorhexis technique, J Cataract Refract Surg, 16, 31, 10.1016/S0886-3350(13)80870-X Neuhann, 1987, Theorie und Operationstechnik der Kapsulorhexis, Klin Monatsbl Augenheilkd, 190, 542, 10.1055/s-2008-1050454 Fritz, 1998, Fluorescein blue, light-assisted capsulorhexis for mature or hypermature cataract, J Cataract Refract Surg, 24, 19, 10.1016/S0886-3350(98)80069-2 Nahra, 1998, Fluorescein-stained capsulorhexis, J Cataract Refract Surg, 24, 1169, 10.1016/S0886-3350(98)80002-3 Pandey SK, Werner L, Escobar-Gomez M, et al. Dye-enhanced cataract surgery. Part 1: anterior capsule staining for capsulorhexis in advanced/white cataract. J Cataract Refract Surg 2000; 26:1052–1059 Melles, 1999, Trypan blue capsule staining to visualize the capsulorhexis in cataract surgery, J Cataract Refract Surg, 25, 7, 10.1016/S0886-3350(99)80004-2 Melles, 1999, Färbung der Linsenkapsel mit Trypanblau zur Visualisierung der Kapsulorhexis bei Maturkataraktchirurgie, Klin Monatsbl Augenheilkd, 215, 342, 10.1055/s-2008-1034729 Nodarian, 2001, Utilisation du bleu trypan pour la réalision du capsulorhexis dans la chirurgie de la cataracte blanch, J Fr Ophtalmol, 24, 274 Bhartiya, 2002, Trypan blue assisted phacoemulsification in corneal opacities, Br J Ophthalmol, 86, 857, 10.1136/bjo.86.8.857 Ünlü, 2000, Gentian violet solution for staining the anterior capsule, J Cataract Refract Surg, 26, 1228, 10.1016/S0886-3350(00)00360-6 Newsom, 2000, Indocyanine green staining in traumatic cataract, J Cataract Refract Surg, 26, 1691, 10.1016/S0886-3350(00)00432-6 Horiguchi, 1998, Staining of the lens capsule for circular continuous capsulorrhexis in eyes with white cataract, Arch Ophthalmol, 116, 535, 10.1001/archopht.116.4.535 Werner L, Pandey SK, Escobar-Gomez M, et al. Dye-enhanced cataract surgery. Part 2: learning critical steps of phacoemulsification. J Cataract Refract Surg 2000; 26:1060–1065 Pandey SK, Werner L, Escobar-Gomez M, et al. Dye-enhanced cataract surgery. Part 3: posterior capsule staining to learn posterior continuous curvilinear capsulorhexis. J Cataract Refract Surg 2000; 26:1066–1071 Yetik, 2002, Determining the lowest trypan blue concentration that satisfactorily stains the anterior capsule, J Cataract Refract Surg, 28, 988, 10.1016/S0886-3350(02)01217-8 Klöti, 1984, Bipolar-Nassfeld-Diathermie in der Mikrochirurgie, Klin Monatsbl Augenheilkd, 184, 442, 10.1055/s-2008-1054517 Klöti, 1992, Vordere Hochfrequenz (HF)-Kapsulotomie, I. Experimentelle Studie. Klin Monatsbl Augenheilkd, 200, 507, 10.1055/s-2008-1045809 Coester, 1992, Vordere Hochfrequenz (HF)-Kapsulotomie, II. Klinisch-chirurgische Erfahrungen. Klin Monatsbl Augenheilkd, 200, 511, 10.1055/s-2008-1045810 Sugimoto, 1997, Histology of anterior capsule edges produced by CCC and DC, Jpn J Ophthalmol, 41, 77, 10.1016/S0021-5155(97)00010-5 Krag, 1997, Diathermic capsulotomy versus capsulorhexis, J Cataract Refract Surg, 23, 86, 10.1016/S0886-3350(97)80156-3 Morgan, 1996, The mechanical properties of the human lens capsule following capsulorhexis or radiofrequency diathermy capsulotomy, Arch Ophthalmol, 114, 1110, 10.1001/archopht.1996.01100140312010 Krag, 1994, Biomechanical aspects of the anterior capsulotomy, J Cataract Refract Surg, 20, 410, 10.1016/S0886-3350(13)80176-9 Nepp, 1996, Inzidenz intraund postoperativer Komplikationen nach Kapsulorhexis und Hochfrequenz-Kapsulotomie, Spektrum Augenheilkd, 10, 60, 10.1007/BF03164177 Kruger, 1997, Intraoperative and postoperative complications of high-frequency capsulotomy and continuous curvilinear capsulorhexis, J Cataract Refract Surg, 23, 429, 10.1016/S0886-3350(97)80189-7 Luck, 1994, A comparative study of the elastic properties of continuous tear curvilinear capsulorhexis versus capsulorhexis produced by radiofrequency endodiathermy, Br J Ophthalmol, 78, 392, 10.1136/bjo.78.5.392 Dodick, 1991, Laser phacolysis of the human cataractous lens, Dev Ophthalmol, 22, 58, 10.1159/000419901 Dodick, 1993, Neodymium-YAG laser phacolysis of the human cataractous lens, Arch Ophthalmol, 111, 903, 10.1001/archopht.1993.01090070021008 Dodick, 1991, Experimental studies on the development and propagation of shock waves created by the interaction of short Nd:YAG laser pulses with a titanium target; possible implications for Nd:YAG laser phacolysis of the cataractous human lens, J Cataract Refract Surg, 17, 794, 10.1016/S0886-3350(13)80414-2 Aron-Rosa, 1984, Use of a picosecond Nd:YAG laser in 6,664 cases, Am Intra-Ocular Implant Soc J, 10, 35, 10.1016/S0146-2776(84)80074-9 Chambless, 1985, Neodymium:YAG laser anterior capsulotomy and a possible new application, Am Intra-Ocular Implant Soc J, 11, 33, 10.1016/S0146-2776(85)80112-9 Reynolds, 1963, The use of lead citrate at high pH as an electron opaque stain in electron microscopy, J Cell Biol, 17, 208, 10.1083/jcb.17.1.208