Tissue damage at anterior capsule edges after continuous curvilinear capsulorhexis, high-frequency capsulotomy, and erbium:YAG laser capsulotomy
Tài liệu tham khảo
Gimbel, 1990, Development, advantages, and methods of the continuous circular capsulorhexis technique, J Cataract Refract Surg, 16, 31, 10.1016/S0886-3350(13)80870-X
Neuhann, 1987, Theorie und Operationstechnik der Kapsulorhexis, Klin Monatsbl Augenheilkd, 190, 542, 10.1055/s-2008-1050454
Fritz, 1998, Fluorescein blue, light-assisted capsulorhexis for mature or hypermature cataract, J Cataract Refract Surg, 24, 19, 10.1016/S0886-3350(98)80069-2
Nahra, 1998, Fluorescein-stained capsulorhexis, J Cataract Refract Surg, 24, 1169, 10.1016/S0886-3350(98)80002-3
Pandey SK, Werner L, Escobar-Gomez M, et al. Dye-enhanced cataract surgery. Part 1: anterior capsule staining for capsulorhexis in advanced/white cataract. J Cataract Refract Surg 2000; 26:1052–1059
Melles, 1999, Trypan blue capsule staining to visualize the capsulorhexis in cataract surgery, J Cataract Refract Surg, 25, 7, 10.1016/S0886-3350(99)80004-2
Melles, 1999, Färbung der Linsenkapsel mit Trypanblau zur Visualisierung der Kapsulorhexis bei Maturkataraktchirurgie, Klin Monatsbl Augenheilkd, 215, 342, 10.1055/s-2008-1034729
Nodarian, 2001, Utilisation du bleu trypan pour la réalision du capsulorhexis dans la chirurgie de la cataracte blanch, J Fr Ophtalmol, 24, 274
Bhartiya, 2002, Trypan blue assisted phacoemulsification in corneal opacities, Br J Ophthalmol, 86, 857, 10.1136/bjo.86.8.857
Ünlü, 2000, Gentian violet solution for staining the anterior capsule, J Cataract Refract Surg, 26, 1228, 10.1016/S0886-3350(00)00360-6
Newsom, 2000, Indocyanine green staining in traumatic cataract, J Cataract Refract Surg, 26, 1691, 10.1016/S0886-3350(00)00432-6
Horiguchi, 1998, Staining of the lens capsule for circular continuous capsulorrhexis in eyes with white cataract, Arch Ophthalmol, 116, 535, 10.1001/archopht.116.4.535
Werner L, Pandey SK, Escobar-Gomez M, et al. Dye-enhanced cataract surgery. Part 2: learning critical steps of phacoemulsification. J Cataract Refract Surg 2000; 26:1060–1065
Pandey SK, Werner L, Escobar-Gomez M, et al. Dye-enhanced cataract surgery. Part 3: posterior capsule staining to learn posterior continuous curvilinear capsulorhexis. J Cataract Refract Surg 2000; 26:1066–1071
Yetik, 2002, Determining the lowest trypan blue concentration that satisfactorily stains the anterior capsule, J Cataract Refract Surg, 28, 988, 10.1016/S0886-3350(02)01217-8
Klöti, 1984, Bipolar-Nassfeld-Diathermie in der Mikrochirurgie, Klin Monatsbl Augenheilkd, 184, 442, 10.1055/s-2008-1054517
Klöti, 1992, Vordere Hochfrequenz (HF)-Kapsulotomie, I. Experimentelle Studie. Klin Monatsbl Augenheilkd, 200, 507, 10.1055/s-2008-1045809
Coester, 1992, Vordere Hochfrequenz (HF)-Kapsulotomie, II. Klinisch-chirurgische Erfahrungen. Klin Monatsbl Augenheilkd, 200, 511, 10.1055/s-2008-1045810
Sugimoto, 1997, Histology of anterior capsule edges produced by CCC and DC, Jpn J Ophthalmol, 41, 77, 10.1016/S0021-5155(97)00010-5
Krag, 1997, Diathermic capsulotomy versus capsulorhexis, J Cataract Refract Surg, 23, 86, 10.1016/S0886-3350(97)80156-3
Morgan, 1996, The mechanical properties of the human lens capsule following capsulorhexis or radiofrequency diathermy capsulotomy, Arch Ophthalmol, 114, 1110, 10.1001/archopht.1996.01100140312010
Krag, 1994, Biomechanical aspects of the anterior capsulotomy, J Cataract Refract Surg, 20, 410, 10.1016/S0886-3350(13)80176-9
Nepp, 1996, Inzidenz intraund postoperativer Komplikationen nach Kapsulorhexis und Hochfrequenz-Kapsulotomie, Spektrum Augenheilkd, 10, 60, 10.1007/BF03164177
Kruger, 1997, Intraoperative and postoperative complications of high-frequency capsulotomy and continuous curvilinear capsulorhexis, J Cataract Refract Surg, 23, 429, 10.1016/S0886-3350(97)80189-7
Luck, 1994, A comparative study of the elastic properties of continuous tear curvilinear capsulorhexis versus capsulorhexis produced by radiofrequency endodiathermy, Br J Ophthalmol, 78, 392, 10.1136/bjo.78.5.392
Dodick, 1991, Laser phacolysis of the human cataractous lens, Dev Ophthalmol, 22, 58, 10.1159/000419901
Dodick, 1993, Neodymium-YAG laser phacolysis of the human cataractous lens, Arch Ophthalmol, 111, 903, 10.1001/archopht.1993.01090070021008
Dodick, 1991, Experimental studies on the development and propagation of shock waves created by the interaction of short Nd:YAG laser pulses with a titanium target; possible implications for Nd:YAG laser phacolysis of the cataractous human lens, J Cataract Refract Surg, 17, 794, 10.1016/S0886-3350(13)80414-2
Aron-Rosa, 1984, Use of a picosecond Nd:YAG laser in 6,664 cases, Am Intra-Ocular Implant Soc J, 10, 35, 10.1016/S0146-2776(84)80074-9
Chambless, 1985, Neodymium:YAG laser anterior capsulotomy and a possible new application, Am Intra-Ocular Implant Soc J, 11, 33, 10.1016/S0146-2776(85)80112-9
Reynolds, 1963, The use of lead citrate at high pH as an electron opaque stain in electron microscopy, J Cell Biol, 17, 208, 10.1083/jcb.17.1.208