Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images

Medical Image Analysis - Tập 2 Số 2 - Trang 143-168 - 1998
Yoshinobu Sato1, Shin Nakajima1, Nobuyuki Shiraga1, Hideki Atsumi1, Shigeyuki Yoshida2, Thomas Koller3, Guido Gerig3, Ron Kikinis1
1Surgical Planning Laboratory, Department of Radiology, Harvard Medical School and Brigham and Women's Hospital, Boston, MA 02115, USA
2Department of Radiology, Osaka University, Medical School, Japan
3Communication Technology Laboratory, Image Science, ETH-Zentrum, Switzerland

Tóm tắt

Từ khóa


Tài liệu tham khảo

Burt, 1983, The Laplacian pyramid as a compact image code, IEEE Trans. Commun., 31, 532, 10.1109/TCOM.1983.1095851

Du, 1994, Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography, J. Magn. Reson. Imag., 4, 733, 10.1002/jmri.1880040517

Du, 1995, Vessel enhancement filtering in three-dimensional MR angiography, J. Magn. Reson. Imag., 5, 151, 10.1002/jmri.1880050207

Dumoulin, 1989, Three-dimensional phase contrast angiography, Magn. Reson. Med., 9, 139, 10.1002/mrm.1910090117

Edelman, 1990, MR angiography, AJR Am. J. Roentgenol., 154, 937, 10.2214/ajr.154.5.2108568

Fischler, 1981, Detection of roads and linear structures in low-resolution aerial imagery using a multi source knowledge integration, Comput. Graphics Image Process., 15, 201, 10.1016/0146-664X(81)90056-3

Gauch, 1993, Multiresolution analysis of ridges and valleys in grey-scale images, IEEE Trans. PAMI, 15, 635, 10.1109/34.216734

Goodenough, 1974, Radiographic applications of receiver operating characteristics (ROC) curves, Radiology, 110, 89, 10.1148/110.1.89

Haralick, 1983, The topographic primal sketch, Int. J. Robotic Res., 2, 50, 10.1177/027836498300200105

Hylton, 1992, Impact of section doubling on MR angiography, Radiology, 185, 899, 10.1148/radiology.185.3.1438782

Isobe, 1993, Characteristics of quoit filter, a digital filter developed for the extraction of circumscribed shadows, and its application to mammograms, IEICE Trans., 279

Kikinis, 1996, Computer-assisted interactive three-dimensional planning for neurosurgical procedures, Neurosurgery, 38, 640, 10.1227/00006123-199604000-00003

Kitamura, 1989, Estimating the 3-D skeletons and transverse areas of coronary arteries from biplane angiograms, IEEE Trans. Med. Imag., 7, 173, 10.1109/42.7779

Koller, 1995, Multi-scale detection of curvilinear structures in 2-D and 3-D image data, 864

Lacroute, 1994, Fast volume rendering using a shear-warp factorization of the viewing transform, Proc. SIGGRAPH'94, 451, 10.1145/192161.192283

Levoy, 1988, Display of surfaces from volume data, IEEE Comp. Graphics Appl., 8, 29, 10.1109/38.511

Lewis, 1996

Lindeberg, 1996, Edge detection and ridge detection with automatic scale selection, Proc. IEEE Computer Socity Conf. on Computer Vision and Pattern Recognition (CVPR'96), 465, 10.1109/CVPR.1996.517113

Lock, 1995, Multidimensional adaptive filtering of MRA data, Proc. Society of Magnetic Resonance and European Society for Magnetic Resonance in Medicine and Biology Joint Meeting

Lorenz, 1997, Multi-scale line segmentation with automatic estimation of width, contrast and tangential direction in 2D and 3D medical images, Proc. 1st Joint Conf. CVRMed and MRCAS (CVRMed/MRCAS'97), 233, 10.1007/BFb0029242

Mori, 1995, Automated extraction and visualization of bronchus from 3D CT images of lung, Proc. 1st Int. Conf. on Computer Vision, Virtual Reality, and Robotics in Medicine (CVRMed'95), 549

Nakajima, 1997, Use of cortical surface vessel registration for image-guided neurosurgery, Neurosurgery, 40, 1201, 10.1097/00006123-199706000-00018

Prince, 1993, Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography, J. Magn. Reson. Imag., 3, 877, 10.1002/jmri.1880030614

Rosenfeld, 1971, Edge and curve detection for visual scene analysis, IEEE Trans. Computer, 20, 562, 10.1109/T-C.1971.223290

Rougée, 1994, Three-dimensional coronary arteriography, Int. J. Cardiac Imag., 10, 67, 10.1007/BF01151583

Sato, 1997, Automatic extraction and measurement of leukocyte motion in microvessels using spatiotemporal image analysis, IEEE Trans. Biomed. Engng, 44, 225, 10.1109/10.563292

Sato, 1997, 3D multi-scale line filter for segmentation and visualization of curvilinear structures in medical images, Proc. 1st Joint Conf. on CVRMed and MRCAS (CVRMed/MRCAS'97), 213, 10.1007/BFb0029240

Sato, 1997, Tissue classification based on 3D local intensity structures for volume rendering, Proc. JAMIT Frontier '97, 167

Sato, 1998, A viewpoint determination system for stenosis diagnosis and quantification in coronary angiographic image acquisition, IEEE Trans. Med. Imag., 17

Schroeder, 1996

Shimizu, 1993, Minimum directional difference filter for extraction of circumscribed shadows in chest X-ray images and its characteristics, IEICE Trans., 241

Vandarbrug, 1975, Semilinear line detectors, Comput. Graphics Image Process., 4, 287, 10.1016/0146-664X(75)90015-5

Vandermeulen, 1992, Local filtering and global optimisation methods for 3D magnetic resonance angiography (MRA) image enhancement, Proc. Visualization in Biomedical Computing (VBC'92), 274, 10.1117/12.131084

Westin, 1994, A Tensor Framework for Multidimensional Signal Processing

Yamamoto, 1996, Quoit filter: a new filter based on mathematical morphology to extract the isolated shadow, and its application to automatic detection of lung cancer in X-ray CT, Proc. 13th Int. Conf. Pattern Recognition (ICPR'96), 2, 3