Thermal neutron detection by means of Timepix3

The European Physical Journal Plus - Tập 138 - Trang 1-8 - 2023
A. Tamburrino1,2,3, G. Claps2,3, G. M. Contessa4, A. Pietropaolo2,3, F. Cordella2,3, V. De Leo2,3, R. M. Montereali2, M. A. Vincenti2, V. Nigro2, R. Gatto1, D. Pacella2,3
1Department of Astronautical, Electrical and Energy Engineering; Sapienza University of Rome, Rome, Italy
2ENEA Frascati Research Center, Frascati, Italy
3INFN Frascati National Laboratory (LNF), Frascati, Italy
4Italian National Institute of Health, Rome, Italy

Tóm tắt

Thermal neutron detection plays a crucial role in numerous scientific and technical applications such as nuclear reactor physics, particle accelerators, radiotherapy, materials analysis and space exploration. There are several challenges associated with the accurate identification and quantification of thermal neutrons. The present work proposes a detailed characterization of a Timepix3 (TPX3) detector equipped with a Lithium Fluoride ( $$^6$$ LiF) converter in order to study its response to thermal neutrons that are identified through the $$^6$$ Li(n, $$\alpha$$ ) $$^3$$ H reaction. The TPX3-based test system has been installed at the HOTNES facility in ENEA and the analysis highlighted its excellent performance showing high effectiveness in the identification of neutrons through morphological analysis of tracks produced by alpha and triton particles, after accurate discrimination from the gamma background. With the use of Monte Carlo simulations, it has been demonstrated that the main contribution is due to tritons and its signal can be used effectively in the identification of thermal neutrons obtaining an efficiency of 0.9 % for 25 meV neutrons. This allows the TPX3 to have important applications as an environmental monitor for thermal neutrons. This monitoring system can be simply realized and is easy to manage because of its compact size and its digital acquisition that allows a real-time analysis.

Tài liệu tham khảo

B. Bergmann, T. Billoud, C. Leroy, S. Pospisil, Characterization of the radiation field in the atlas experiment with timepix detectors. IEEE Trans. Nucl. Sci. (2019). https://doi.org/10.1109/TNS.2019.2918365 P. Burian, P. Broulím, B. Bergmann, V. Georgiev, S. Pospíšil, L. Pušmana, J. Zicha, Timepix3 detector network at atlas experiment. J. Instrum. (2018). https://doi.org/10.1088/1748-0221/13/11/C11024 Medipix Collaboration (2004). https://medipix.web.cern.ch/medipix/ D. Pacella, Energy-resolved x-ray detectors: The future of diagnostic imaging. Dove Press 8, 1–13 (2015). https://doi.org/10.2147/RMI.S50045 A. Pietropaolo, G. Verona Rinati, C. Verona, E.M. Schooneveld, M. Angelone, M. Pillon, A single-crystal diamond-based thermal neutron beam monitor for instruments at pulsed neutron sources. Nucl. Instrum. Methods Phys. Res. A 610, 677–681 (2009) https://doi.org/10.1016/j.nima.2009.09.013 V. Merlo, M. Salvato, M. Cirillo, M. Lucci, I. Ottaviani, A. Scherillo, G. Celentano, A. Pietropaolo, Hybrid superconducting neutron detectors. Appl. Phys. Lett. (2015). https://doi.org/10.1063/1.4915608 P. Burian, P. Broulim, M. Jara, V. Georgiev, B. Bergmann, Katherine: Ethernet Embedded Readout Interface for timepix3. J. Instrum. (2017). https://doi.org/10.1088/1748-0221/12/11/C11001 IEAP Software Repository (2021). https://software.utef.cvut.cz G. Claps, F. Murtas, L. Foggetta, C. Di Giulio, J. Alozy, G. Cavoto, Diamondpix: A CVD diamond detector with timepix3 chip interface. IEEE Trans. Nucl. Sci. 65(10), 2743–2753 (2018). https://doi.org/10.1109/TNS.2018.2871605 J. Leidner, F. Murtas, M. Silari, Energy calibration of the Gempix in the energy range of 6 kev to 2mev. J. Instrum. (2021). https://doi.org/10.1088/1748-0221/16/10/P10004 FLUKA. https://fluka.cern J. Jakubek, Precise energy calibration of pixel detector working in time-over-threshold mode. Nucl. Instrum. Methods Phys. Res. A (2010). https://doi.org/10.1016/j.nima.2010.06.183 A. Sperduti, M. Angelone, R. Bedogni, G. Claps, E. Diociaiuti, C. Domingo, R. Donghia, S. Giovannella, J.M. Gomez-Ros, L. Irazola-Rosales, S. Loreti, V. Monti, S. Miscetti, F. Murtas, G. Pagano, M. Pillon, R. Pilotti, A. Pola, M. Romero-Expósito, F. Sánchez-Doblado, O. Sans-Planell, A. Scherillo, E. Soldani, M. Treccani, A. Pietropaolo, Results of the first user program on the homogeneous thermal neutron source hotnes (enea/infn). J. Instrum. (2017). https://doi.org/10.1088/1748-0221/12/12/P12029 R. Bedogni, A. Sperduti, A. Pietropaolo, M. Pillon, A. Pola, J.M. Gómez-Rosa, Experimental characterization of hotnes: A new thermal neutron facility with large homogeneity area. Nucl. Instrum. Methods Phys. Res. A (2017). https://doi.org/10.1016/j.nima.2016.10.056 A. Tamburrino, G. Claps, F. Cordella, F. Murtas, D. Pacella, Timepix3 detector for measuring radon decay products. J. Instrum. (2022). https://doi.org/10.1088/1748-0221/17/06/P06009 A. Pietropaolo, F. Murtas, G. Claps, L. Quintieri, D. Raspino, G. Celentano, A. Vannozzi, O. Frasciello, A new 3he-free thermal neutrons detector concept based on the gem technology. Nucl. Instrum. Methods Phys. Res. A (2013). https://doi.org/10.1016/j.nima.2013.06.058 D.S. McGregor, M.D. Hammig, Y.-H. Yang, H.K. Gersch, R.T. Klann, Design considerations for thin film coated semiconductor thermal neutron detectors-i: basics regarding alpha particle emitting neutron reactive films. Nucl. Instrum. Methods Phys. Res. A (2003). https://doi.org/10.1016/S0168-9002(02)02078-8