The use of uniaxial accelerometry for the assessment of physical-activity-related energy expenditure: a validation study against whole-body indirect calorimetry

British Journal of Nutrition - Tập 91 Số 2 - Trang 235-243 - 2004
Hideaki Kumahara1, Yves Schütz2, Makoto Ayabe3, Mayumi Yoshioka4, Yutaka YOSHITAKE5, Munehiro Shindo6, Kojiro Ishii3, Hiroaki Tanaka6
1Laboratory of Physiology, Faculty of Medicine, University of Lausanne, Lausanne, Switzerland.
2Institute of Physiology, Faculty of Medicine, University of Lausanne, Lausanne, Switzerland
3 Laboratory of Human Performance and Fitness, Graduate School of Education, Hokkaido University, Sapporo, Hokkaido, Japan
4Molecular Endocrinology and Oncology Research Center, Laval University Medical Center and Laval University, Quebec, Canada
5Department for Interdisciplinary Studies of Lifelong Sport and Physical Activity, National Institute of Fitness and Sports in Kanoya, Kanoya, Kagoshima, Japan
6Laboratory of Exercise Physiology, Faculty of Sports and Health Science, Fukuoka University, Fukuoka, Japan

Tóm tắt

Assessing the total energy expenditure (TEE) and the levels of physical activity in free-living conditions with non-invasive techniques remains a challenge. The purpose of the present study was to investigate the accuracy of a new uniaxial accelerometer for assessing TEE and physical-activity-related energy expenditure (PAEE) over a 24 h period in a respiratory chamber, and to establish activity levels based on the accelerometry ranges corresponding to the operationally defined metabolic equivalent (MET) categories. In study 1, measurement of the 24 h energy expenditure of seventy-nine Japanese subjects (40 (SD 12) years old) was performed in a large respiratory chamber. During the measurements, the subjects wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd, Nagoya, Japan) on their belt. Two moderate walking exercises of 30 min each were performed on a horizontal treadmill. In study 2, ten male subjects walked at six different speeds and ran at three different speeds on a treadmill for 4 min, with the same accelerometer. O2 consumption was measured during the last minute of each stage and was expressed in MET. The measured TEE was 8447 (SD 1337) kJ/d. The accelerometer significantly underestimated TEE and PAEE (91·9 (SD 5·4) and 92·7 (SD 17·8) % chamber value respectively); however, there was a significant correlation between the two values (r 0·928 and 0·564 respectively; P<0·001). There was a strong correlation between the activity levels and the measured MET while walking (r2 0·93; P<0·001). Although TEE and PAEE were systematically underestimated during the 24 h period, the accelerometer assessed energy expenditure well during both the exercise period and the non-structured activities. Individual calibration factors may help to improve the accuracy of TEE estimation, but the average calibration factor for the group is probably sufficient for epidemiological research. This method is also important for assessing the diurnal profile of physical activity.

Từ khóa


Tài liệu tham khảo

10.1249/00005768-199412000-00017

10.1093/ajcn/38.6.989

10.1152/jappl.1996.81.2.1019

10.1126/science.283.5399.212

1996, Recommended Dietary Allowances for the Japanese, 20

10.1097/00005768-199805000-00021

10.1016/S0140-6736(52)90543-6

10.1152/jappl.1997.83.6.2112

10.1038/sj.ijo.0801085

10.1097/00005768-199901000-00026

10.1017/S0007114500000908

10.1001/jama.1995.03520290054029

10.1038/oby.2001.48

10.1097/00005768-200109000-00024

Fleisch, 1951, Le métabolisme basal standard et sa détermination au moyen du "Metabocalculator" (Basal standard metabolic rate and its determination by means of the "Metabocalculator"), Helv Med Acta, 18, 23

10.1016/S0002-9343(98)00190-9

10.1080/00140130118289

10.7600/jspfsm1949.51.151

10.1097/00005768-200009001-00006

10.1016/S0140-6736(86)90837-8

10.1249/00005768-199412000-00016

10.1111/j.1749-6632.1963.tb17079.x

10.1093/ajcn/75.3.453

10.1097/00005768-199906000-00022

Food and Agriculture Organization/World Health Organization/United Nations University (1985) Energy and Protein Requirements. Report of a Joint FAO/WHO/UNU Expert Consultation. Technical Report Series no. 724 Geneva: WHO.

10.1265/jjh.23.443

Du Bois, 1916, Clinical calorimetry: a formula to estimate the approximate surface area if height and weight be known, Arch Med, 17, 863

Harris, 1919, A Biometric Study of Basal Metabolism in Man. Publication no. 279

10.1249/00005768-199312000-00008

10.1038/sj.ijo.0801049

10.1038/sj.ijo.0801644

10.1249/00005768-198906000-00020

Nagamine, 1964, Anthropometry and body composition of Japanese young men and women, Hum Biol, 36, 8

Schutz, 1982, Spontaneous physical activity measured by radar in obese and control subject studied in a respiration chamber, Int J Obes, 6, 23

Suzuki, 1997, Accuracy of calorie counter method to assess daily energy expenditure and physical activities in athletes and nonathletes, J Sports Med Phys Fitness, 37, 131

Yamada, 1990, Validity of daily energy expenditure estimated by calorie counter combined with accelerometer, J Univ Occup Environ Health, 12, 77