The repeatability of pressure algometry in asymptomatic individuals over consecutive days

International Journal of Osteopathic Medicine - Tập 16 Số 3 - Trang 143-152 - 2013
Laura L. Frank1, Patrick McLaughlin2,1, Brett Vaughan2,1
1Osteopathy Unit, School of Biomedical & Health Sciences, Victoria University, Australia
2Institute of Sport, Exercise & Active Living, Victoria University, Australia

Tóm tắt

Từ khóa


Tài liệu tham khảo

Keating, 2001, Mid-thoracic tenderness: a comparison of pressure pain threshold between spinal regions, in asymptomatic subjects, Man Ther, 6, 34, 10.1054/math.2000.0377

Vatine, 1993, Electronic pressure algometry of deep pain in healthy volunteers, Arch Phys Med Rehabil, 74, 526, 10.1016/0003-9993(93)90118-T

Farella, 2000, The diagnostic value of pressure algometry in myofascial pain of the jaw muscles, J Oral Rehabil, 27, 9, 10.1046/j.1365-2842.2000.00526.x

Ylinen, 2007, Pressure algometry, Aust J Physiother, 53, 207, 10.1016/S0004-9514(07)70032-6

Fisher, 1987, Pressure algometry over normal muscles. Standard values, validity and reproducibility of pressure threshold, Pain, 30, 115, 10.1016/0304-3959(87)90089-3

Nussbaum, 1998, Reliability of clinical pressure-pain algometry measurements obtained on consecutive days, Phys Ther, 78, 160, 10.1093/ptj/78.2.160

Reeves, 1986, Reliability of the pressure algometer as a measure of myofascial trigger point sensitivity, Pain, 24, 313, 10.1016/0304-3959(86)90117-X

Vanderweeen, 1996, Pressure algometry in manual therapy, Man Ther, 1, 258, 10.1054/math.1996.0276

Sterling, 1996, Are cervical physical outcome measures influenced by the presence of symptomatology?, Physiother Res Int, 7, 113, 10.1002/pri.248

Jensen, 1986, Pressure-pain threshold in human temporal region: evaluation of a new pressure algometer, Pain, 25, 313, 10.1016/0304-3959(86)90235-6

Ohrbach, 1989, Pressure-pain thresholds in normal muscles: reliability, measurement effects, and topographic differences, Pain, 37, 257, 10.1016/0304-3959(89)90189-9

Potter, 2006, Algometer reliability in measuring pain pressure threshold over normal spinal muscles to muscles to allow quantification of anti-nociceptive treatment effects, Int J Ost Med, 9, 113, 10.1016/j.ijosm.2006.11.002

van Wilgen, 2011, Feasibility and reliability of pressure pain threshold measurements in patellar tendinopathy, J Sci Med Sport, 10.1016/j.jsams.2011.05.004

Vaughan, 2007, Validity of a pressure algometer, Int J Ost Med, 10, 24, 10.1016/j.ijosm.2006.12.003

Persson, 2004, Tender or not tender: retest repeatability of pressure pain thresholds in the trapezius and deltoid muscles of healthy women, J Rehabil Med, 36, 17, 10.1080/16501970310015218

Kinser, 2009, Reliability and validity of a pressure algometer, J Strength Cond Res, 23, 312, 10.1519/JSC.0b013e31818f051c

Fleiss, 1986

Londoree, 1990, Testing for hypothesized equality, Res Q Exerc Sport, 61, 275, 10.1080/02701367.1990.10608691