The potential role of MR-guided adaptive radiotherapy in pediatric oncology: Results from a SIOPE-COG survey
Tài liệu tham khảo
Verkooijen, 2017, R-IDEAL: A framework for systematic clinical evaluation of technical innovations in radiation oncology, Front Oncol, 7, 10.3389/fonc.2017.00059
Cao Y, Tseng CL, Balter JM, Teng F, Parmar HA, Sahgal A, 2017, MR-guided radiation therapy: transformative technology and its role in the central nervous system. Neuro-Oncology, 19(2), ii16–ii29. https://dx.doi.org/10.1093/neuonc/nox006.
Henke, 2016, Simulated online adaptive magnetic resonance-guided stereotactic body radiation therapy for the treatment of oligometastatic disease of the abdomen and central thorax: Characterization of potential advantages, Int J Radiat Oncol Biol Phys, 96, 1078, 10.1016/j.ijrobp.2016.08.036
Vestergaard, 2016, The potential of MRI-guided online adaptive re-optimisation in radiotherapy of urinary bladder cancer, Radiother Oncol, 118, 154, 10.1016/j.radonc.2015.11.003
Winkel, 2018, Simulated dosimetric impact of online replanning for stereotactic body radiation therapy of lymph node oligometastases on the 1.5T MR-linac, Acta Oncol, 57, 1705, 10.1080/0284186X.2018.1512152
Yang, 2016, Longitudinal diffusion MRI for treatment response assessment: Preliminary experience using an MRI-guided tri-cobalt 60 radiotherapy system, Med Phys, 43, 1369, 10.1118/1.4942381
Acharya, 2016, Online magnetic resonance image guided adaptive radiation therapy: First clinical applications, Int J Radiat Oncol Biol Phys, 94, 394, 10.1016/j.ijrobp.2015.10.015
Chin, 2020, Magnetic resonance-guided radiation therapy: A review, J Med Imag Radiation Oncol, 64, 163, 10.1111/1754-9485.12968
Hunt, 2020, Feasibility of magnetic resonance guided radiotherapy for the treatment of bladder cancer, Clin Transl Radiat Oncol, 25, 46, 10.1016/j.ctro.2020.09.002
Winkel, 2020, Target coverage and dose criteria based evaluation of the first clinical 1.5T MR-linac SBRT treatments of lymph node oligometastases compared with conventional CBCT-linac treatment, Radiother Oncol, 146, 118, 10.1016/j.radonc.2020.02.011
de Muinck Keizer, 2020, Prostate intrafraction motion during the preparation and delivery of MR-guided radiotherapy sessions on a 1.5T MR-Linac, Radiother Oncol, 151, 88, 10.1016/j.radonc.2020.06.044
Tetar, 2019, Clinical implementation of magnetic resonance imaging guided adaptive radiotherapy for localized prostate cancer, Phys Imag Radiat Oncol, 9, 69, 10.1016/j.phro.2019.02.002
Güngör, 2020, Time analysis of online adaptive magnetic resonance-guided radiation therapy workflow according to anatomical sites, Practical Radiat Oncol, 1–11
Dunlop, 2020, Daily adaptive radiotherapy for patients with prostate cancer using a high field MR-linac: Initial clinical experiences and assessment of delivered doses compared to a C-arm linac, Clin Transl Radiat Oncol, 23, 35, 10.1016/j.ctro.2020.04.011
Henke, 2019, First reported case of pediatric radiation treatment with magnetic resonance image guided radiation therapy, Adv Radiat Oncol, 4, 233, 10.1016/j.adro.2019.01.008
Egriboyun ES, Ugurluer G, Corapcioglu FV, Celik L, Gungor G, Atalar B, et al. accepted, Magnetic resonance image-guided stereotactic body radiation therapy for liver rhabodi tumor in infancy: A case report. J Med Imag Radiat Sci.
Leibfarth, 2018, Potentials and challenges of diffusion-weighted magnetic resonance imaging in radiotherapy, Clin Transl Radiat Oncol, 13, 29, 10.1016/j.ctro.2018.09.002
Datta, 2018, Delivering functional imaging on the MRI-Linac: Current challenges and potential solutions, Clin Oncol, 30, 702, 10.1016/j.clon.2018.08.005
Houdt PJ, Saeed H, Thorwarth D, Fuller CD, Hall WA, McDonald BA, et al., 2021, Integration of quantitative imaging biomarkers in clinical trials for MR-guided radiotherapy: Conceptual guidance for multicenter studies from the MR-Linac Consortium Imaging Biomarker Working Group, accepted in European Journal of Cancer.
Kooreman, 2020, ADC measurements on the Unity MR-linac - A recommendation on behalf of the Elekta Unity MR-linac consortium, Radiother Oncol, 153, 106, 10.1016/j.radonc.2020.09.046
Kerkmeijer, 2016, The MRI-linear accelerator consortium: Evidence-based clinical introduction of an innovation in radiation oncology connecting researchers, methodology, data collection, quality assurance, and technical development, Front Oncol, 6, 10.3389/fonc.2016.00215
Sim AJ, Kaza E, Singer L, Rosenberg SA, 2020. A review of the role of MRI in diagnosis and treatment of early stage lung cancer. Clin Transl Radiat Oncol. 24:16–22. https://dx.dooi.org/10.1016/j.ctro.2020.06.002.
Crockett, 2021, Initial clinical experience of MR-guided radiotherapy for non-small cell lung cancer, Front Oncol., 11, 10.3389/fonc.2021.617681
Feldman, 2019, Real-time magnetic resonance-guided liver stereotactic body radiation therapy: An institutional report using a magnetic resonance-linac system, Cureus, 11
Huijskens SC, Kroon PS, Gaze MN, Gandola L, Bolle S, Supiot S, et al., 2021. Radical radiotherapy for paediatric solid tumour metastases: An overview of current European protocols and outcomes of a SIOPE multicenter survey. Eur J Cancer, 145(2020), 121–131. https://dx.doi.org/10.1016/j.ejca.2020.12.004.
Janssens, 2020, The SIOP-Renal Tumour Study Group consensus statement on flank target volume delineation for highly conformal radiotherapy, Lancet Child Adoles Health, 4, 846, 10.1016/S2352-4642(20)30183-8
Cardenas, 2019, Advances in auto-segmentation, Semi Radiat Oncol, 29, 185, 10.1016/j.semradonc.2019.02.001
Savenije, 2020, Clinical implementation of MRI-based organs-at-risk auto-segmentation with convolutional networks for prostate radiotherapy, Radiat Oncol, 15, 1, 10.1186/s13014-020-01528-0
Song, 2020, Automatic delineation of the clinical target volume and organs at risk by deep learning for rectal cancer postoperative radiotherapy, Radiother Oncol, 145, 186, 10.1016/j.radonc.2020.01.020
Müller, 2019, Benchmarking Wilms’ tumor in multisequence MRI data: why does current clinical practice fail? Which popular segmentation algorithms perform well?, J Med Imaging, 6, 1, 10.1117/1.JMI.6.3.034001
Baranska, 2019, Feasibility of diffusion-weighted imaging with DWIBS in staging Hodgkin lymphoma in pediatric patients: comparison with PET/CT, Magn Reson Mater Phys Biol Med, 32, 381, 10.1007/s10334-018-0726-4
Chavhan, 2016, Diffusion-weighted imaging in pediatric body magnetic resonance imaging, Pediatr Radiol, 46, 847, 10.1007/s00247-016-3573-3
Manias, 2017, Magnetic resonance imaging based functional imaging in paediatric oncology, Eur J Cancer, 72, 251, 10.1016/j.ejca.2016.10.037
Merchant, 2013, Disease control after reduced volume conformal and intensity modulated radiation therapy for childhood craniopharyngioma, Int J Radiat Oncol Biol Phys, 85, e187, 10.1016/j.ijrobp.2012.10.030
Acharya, 2021, Adaptive proton therapy for pediatric patients: Improving the quality of the delivered plan with on-treatment MRI, Int J Radiat Oncol Biol Phys, 109, 242, 10.1016/j.ijrobp.2020.08.036
Raper, 2015, Multiple anesthetic exposure in infant monkeys alters emotional reactivity to an acute stressor, Anesthesiology, 123, 1084, 10.1097/ALN.0000000000000851
Seiler, 2001, Evaluation of the safety and efficacy of repeated sedations for the radiotherapy of young children with cancer: A prospective study of 1033 consecutive sedations, Int J Radiat Oncol Biol Phys, 49, 771, 10.1016/S0360-3016(00)01357-2
Ing, 2012, Long-term differences in language and cognitive function after childhood exposure to anesthesia, Pediatrics, 130, e476, 10.1542/peds.2011-3822
Fortney JT, Halperin EC, Hertz CM, Schulman SR. Clinical investigation pediatric tumors anesthesia for pediatric external beam radiation therapy, 44(3); 1999: 587–591.
Gooden CK, Dilos B. Anesthesia for magnetic resonance imaging. Int Anesthesiol Clin, 41(2); 2003: 29–37.
Salerno, 2018, Is MRI imaging in pediatric age totally safe? A critical reprisal, Radiol Med, 123, 695, 10.1007/s11547-018-0896-1
Salvi, 2018, Is noise in the MR imager a significant risk factor for hearing loss?, Radiology, 286, 609, 10.1148/radiol.2017172221
Amaro, 2002, Acoustic noise and functional magnetic resonance imaging: Current strategies and future prospects, J Magn Reson Imaging, 16, 497, 10.1002/jmri.10186
Gallagher, 2011, Attenuation performance of double hearing protection devices, Proc Meetings Acoust, 11, 10.1121/1.3626895