The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair

Springer Science and Business Media LLC - Tập 138 - Trang 139-145 - 2017
B. Wieskötter1, M. Herbort1, M. Langer1, M. J. Raschke1, D. Wähnert1,2
1Department of Trauma, Hand and Reconstructive Surgery, University Hospital Muenster, Muenster, Germany
2Institute of Experimental Musculoskeletal Medicine, Westfaelische-Wilhelms-University Muenster, Muenster, Germany

Tóm tắt

Flexor tendon repair consists of circumferential peripheral sutures in combination with core sutures to avoid fraying and reduces the exposure of suture material on tendon surface. The peripheral suture adds up to a tenfold increase of the biomechanical stability compared to the core suture alone. The purpose of our study was to determine the most favourable peripheral repair technique for tendon repair. Seventy-two porcine flexor tendons underwent standardized tenotomy and repair using one of the following six methods (n = 12): simple-running (SR), simple-locking (SL), Halsted-mattress (HM), lin-locking (LL), Lembert-mattress (LM), and Silfverskiöld cross-stich (SCS) suture technique. The SL- suture was placed 2 mm; the HM, LM, SC, and LL suture were placed 5 mm from the tendon gap. The SR suture was placed 1, 2, and 3 mm from tendon ends; no additional core suture was applied. For cyclic testing (1000 cycles), elongation was calculated; for load to failure construct stiffness, yield load and maximum load were determined. The mean cyclic elongation for all tested suture techniques was less than 2 mm; there was no significant difference between the groups regarding elongation as well as yield load. The HM, LM, SCS, and LL suture techniques presented significantly higher maximum loads compared to the SR- and SL-sutures. The 3 mm SR showed significantly higher maximum loads compared to the 2 and 1 mm SR. Beside the distance from tendon gap, the type of linkage of the suture material across and beneath the epitendineum is important for biomechanical stability. Simple-running suture is easy to use, even with a slight increase of the distance from tendon gap significantly increases biomechanical strength. For future repairs of flexor tendon injuries, 3 mm stitch length is highly recommended for simple peripheral suture, while the Halsted-mattress suture unites the most important qualities: biomechanically strong, most part of suture material placed epitendinous, and not too complicated to perform.

Tài liệu tham khảo

Hahn P, Unglaub F, Spies CK (2015) Diagnosis of flexor tendon injuries of the hand. Orthopade;44(10):743–747 Lister GD, Kleinert HE, Kutz JE (1977) Primary flexor tendon repair followed by immediate controlled mobilization. J Hand Surg Am 2:441–451 Langer MF, Oeckenpöhler S, Kösters C, Herrmann K, Wieskötter B (2015) Suture techniques for flexor tendons of the hand. Orthopade 44(10):748–756 Lotz J, Hariharan JS, Diao E (1998) Analytic model to predict the strength of tendon repairs. J Orthop Res 16:399–405 Mashadi ZB, Amis AA (1992) Strength of the suture in the epitenon and within the tendon fibers: development of stronger peripheral suture technique. J Hand Surg Br 17(2):172–175 Pruitt DL, Manske PR, Fink B (1991) Cyclic stress analysis of flexor tendon repair. J Hand Surg 16A:701–707 Wade P, Muir I, Hutcheon L (1986) Primary flexor tendon repair—the mechanical limitations of the modified Kessler technique. J Hand Surg 11B:71–76 Gelberman RH, Woo SL, Lothringer K, Akeson WH, Amiel D (1982) Effects of early intermittent passive mobilization on healing canine flexor tendons. J Hand Surg Am 7:170–175 Peck FH, Bücher CA, Watson JS (1998) A comparative study of two methods of controlled mobilization of flexor tendon repairs in zone 2. J Hand Surg Br 23:41–45 Quadlbauer S, Pezzei Ch, Jurkowitsch J, Reb P, Beer T, Leixnering M (2016) Early Passive Movement in flexor tendon injuries of the hand. Arch Orthop Trauma Surg Feb 136(2):285–293 Elliot D, Moiemen NS, Flemming AF, Harris SB, Foster AJ (1994) The rupture rate of acute flexor tendon repairs mobilized by the controlled active motion regimen. J Hand Surg 19B:607–612 Barrie KA, Tomak SL, Cholewicki J, Merrell GA, Wolfe SW (2001) Effect of suture locking and suture caliber on fatigue strength of flexor tendon repairs. J Hand Surg 26A:340–346 Dona E, Turner AW, Gianoutsos MP, Walsh WR (2003) Biomechanical properties of four circumferential flexor tendon suture techniques. J Hand Surg 28A:824–831 Lin GT, An KN, Amadio PC, Cooney WP (1988) Biomechanical studies of running suture for flexor tendon repair in dogs. J Hand Surg 13A:553–558 Takeuchi N, Mitsuyasu H, Hotokezaka S, Miura H, Higaki H, Iwamoto Y (2010) Strength enhancement of the interlocking mechanism in cross-stitch peripheral sutures for flexor tendon repair: biomechanical comparisons by cyclic loading. J Hand Surg Eur 35(1):46–50 Choueka J, Heminger H, Mass DP (2000) Cyclical testing of zone II flexor tendon repairs. J Hand Surg 25A:1127–1134 Matheson G, Nicklin S, Gianoutsous MP, Walsh WR (2005) Comparison of zone II flexor tendon repairs using an in vitro linear cyclic testing protocol. Clin Biochem 20(7):718–722 Mishra V, Kuiper JH, Kelly CP (2003) Influence of core suture material and peripheral repair technique on the strength of Kessler flexor tendon repair. J Hand Surg 28:357–362 Pruitt DL, Tanaka H, Aoki M, Manske PR (1996) Cyclic stress testing after in vivo healing of canine flexor tendon lacerations. J Hand Surg 21A:974–977 Sanders DW, Milne AD, Dobravec A, MacDermid J, Johnson JA, King GJW (1997) Cyclic testing of flexor tendon repairs: an in vitro biomechanical study. J Hand Surg 22A:1004–1010 Tanaka H, Manske PR, Pruitt DL, Larson BJ (1995) Effect of cyclic tension on lacerated flexor tendons in vitro. J Hand Surg 20A:467–473 Tran H, Cannon DL, Lieber RL, Abrams RA (2002) In vitro cyclic tensile testing of combined peripheral and core flexor tenorrhaphy suture techniques. J Hand Surg 27:518–524 Uslu M, Isik C, Ozsahin M (2014) Flexor tendons repair: effect of core sutures caliber with increased number of suture strands and peripheral sutures. A sheep model. Orthop Traumatol Surg Res 100(6):611–616 Merrell GA, Wolfe SW, Kacena WJ, Gao Y, Cholewicki J, Kacena MA (2003) The effect of increased peripheral suture purchase on the strength of flexor tendon repairs. J Hand Surg 28:464–468 Leddy JP. Flexor tendon- acute injuries. In: Green DP vol 2:pp 1823–1851 Wade PJ, Wetherell RG, Amis AA (1989) Flexor tendon repair—significant gain in strength from the Halsted peripheral suture technique. J Hand Surg. 232–235 Silfverskiold K, Andersson CH (1993) Two new methods of tendon repair- an in vitro evaluation of tensile strength and gap formation. J Hand Surg 18A:58–65 Domnick C, Wieskötter B, Raschke MJ, Schulze M, Kronenberg D, Wefelmeier M, Langer MF, Herbort M (2016) Arch Orthop Trauma Surg 136(10):1465–1471 Havulinna J, Leppänen OV, Järvinen TL, Göransson H (2011) Comparison of modified Kessler tendon suture at different levels in the human flexor digitorum profundus tendon and porcine flexors and porcine extensors: an experimental biomechanical study. J Hand Surg Eur 36(8):670–676 Viinikainen A, Goransson H, Huovinen K, Kellomaki M, Rokkanen P (2004) A comparative analysis of the biomechanical behaviour of five flexor tendon core sutures. J Hand Surg 29:536–543 Wang B, Tang JB (2003) Embedded cross-stitch suture: an alternative to current cross-stitch peripheral suture. J Hand Surg 28:471–474 Zatiti SC, Mazzer N, Barbieri CH (1998) Mechanical strengths of tendon sutures. An in vitro comparative study of six techniques. J Hand Surg 23B:228–233 Hirpara KM, Sullivan PJ, O’Sullivan ME (2008) The effects of freezing on the tensile properties of repaired porcine flexor tendon. J Hand Surg Am 33(3):353–358 Kubota H, Aoki M, Pruitt DL, Manske PR (1996) Mechanical properties of various circumferential tendon suture techniques. J Hand Surg 21B:474–480 Tang JB (2007) Indications, methods, postoperative motion and outcome evaluation of primary flexor tendon repairs in zone 2. J Hand Surg 32:118–129 Yuen MH, Ip WY (2007) Tensile strength of modified 4-strand cruciate technique for transversely or obliquely lacerated tendons. J Orthop Surg (Hong Kong) Apr;15(1):27–31 Boyer M, Gelberman RH, Burns ME, Dinopoulos H, Hofem R, Silva MJ (2001) Intrasynovial flexor tendon repair - An experimental study comparing low and high levels of in vivo force during rehabilitation in canines. J Bone Joint Surg Am 83A:891–899 Ditsios K, Burns ME, Boyer MI, Gelberman RH, Silva MJ (2002) The rigidity of repaired flexor tendons increases following ex vivo cyclic loading. J Biomech 35:853–856 Powell E, Trail IA (2004) Forces transmitted along human flexor tendons during passive and active movements of the fingers. J Hand Surg 29:386–389 Schuind F, Garcia-Elias M, Cooney WP, An KN (1992) Flexor tendon forces -in vivo measurements. J Hand Surg 17A:291–298 Urbaniak JR, Cahill JD, Mortenson RA (1975) Tendon suturing methods: analysis of tensile strengths. AAOS Symposium on Tendon Surgery of the Hand. CV Mosby, St. Louis, pp 70–80 Gibbons CE, Thompson D, Sandow MJ (2009) Flexor tenorrhaphy tensile strength: reduction by cyclic loading: in vitro and ex vivo porcine study. Hand (N Y). Jun;4(2):113–118 Kitsis CK, Wade PJ, Krikler SJ (1998) Controlled active motion following primary flexor tendon repair: a prospective study over 9 years. J Hand Surg Br 23:344–349 Wang B, Tang JB (2002) Increased suture embedment in tendons: an effective method to improve repair strength. J Hand Surg 27:333–336 Hatanaka H, Manske PR (1999) Effect of the cross-sectional area of locking loops in flexor tendon repair. J Hand Surg 24A:751–760 Wichelhaus DA, Beyersdoerfer ST, Gierer P, Vollmar B, Mittlmeier T (2016) The effect of a collagen-elastin matrix on adhesion formation after flexor tendon repair in a rabbit model. Arch Orthop Trauma Surg 136(7):1021–1029