The effects of cyclic loading and preparation on the fracture strength of zirconium-dioxide implants: an in vitro investigation
Tóm tắt
Từ khóa
Tài liệu tham khảo
Adell, 1981, A 15-year study of osseointegrated implants in the treatment of the edentulous jaw, International Journal of Oral Surgery, 10, 387, 10.1016/S0300-9785(81)80077-4
Albrektsson, 1988, Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants, Journal of Periodontology, 59, 287, 10.1902/jop.1988.59.5.287
Andreiotelli, 2009, Fracture strength of zirconia implants after artificial aging, Clinical Implants Dentistry & Related Research, 11, 158, 10.1111/j.1708-8208.2008.00105.x
Andreiotelli, 2009, Are ceramic implants a viable alternative to titanium implants? A systematic literature review, Clinical Oral Implants Research, 20, 32, 10.1111/j.1600-0501.2009.01785.x
Ardlin, 2002, Transformation-toughened zirconia for dental inlays, crowns and bridges, Dental Materials, 18, 590, 10.1016/S0109-5641(01)00095-1
Att, 2007, Fracture resistance of different zirconium dioxide three-unit all-ceramic fixed partial dentures, Acta Odontologica Scandinavica, 65, 14, 10.1080/00016350600856232
Aydin, 2010, Single-tooth zirconia implant located in anterior maxilla. A clinical report, The New York State Dental Journal, 76, 30
Blaschke, 2006, Soft and hard tissue response to zirconium dioxide implants - a clinical study in man, Neuroendocrinology Letters, 27, 69
Brånemark, 1977, Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period, Scandinavian Journal of Plastic and Reconstructive Surgery, 16, 1
Buser, 1997, Long-term evaluation of non-submerged ITI implants. Part I, Clinical Oral Implants Research, 8, 161, 10.1034/j.1600-0501.1997.080302.x
Cales, 1994, Long-term in vivo and in vitro aging of a zirconia ceramic used in orthopaedy, Journal of Biomedical Materials Research, 28, 619, 10.1002/jbm.820280512
Canullo, 2007, Clinical outcome study of customized zirconia abutments for single-implant restorations, International Journal of Prosthodontics, 20, 489
Chevalier, 2006, What future for zirconia as a biomaterial?, Biomaterials, 27, 535, 10.1016/j.biomaterials.2005.07.034
Chevalier, 2007, Low-Temperature degradation of zirconia and implications for biomedical implants, Annual Review of Materials Research, 37, 1, 10.1146/annurev.matsci.37.052506.084250
De Aza, 2002, Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses, Biomaterials, 23, 937, 10.1016/S0142-9612(01)00206-X
DeLong, 1985, The wear of dental amalgam in an artificial mouth, Dental Materials, 1, 238, 10.1016/S0109-5641(85)80050-6
Denry, 2006, Microstructural and crystallographic surface changes after grinding zirconia-based dental ceramics, Journal of Biomedical Materials Research Part B: Applied Biomaterials, 76, 440, 10.1002/jbm.b.30382
Ferrario, 2004, Maximal bite forces in healthy young adults as predicted by surface electromyography, Journal of Dentistry, 32, 451, 10.1016/j.jdent.2004.02.009
Fontijn-Tekamp, 2000, Biting and chewing in overdentures, full dentures, and natural dentitions, Journal of Dental Research, 79, 1519, 10.1177/00220345000790071501
Glauser, 2004, Application of zirconia abutments on single-tooth implants in the maxillary esthetic zone. A 6-year clinical and radiographic follow-up report, Applied Osseointegration Research, 4, 41
Guazzato, 2005, Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic, Journal of Dentistry, 33, 9, 10.1016/j.jdent.2004.07.001
Gupta, 1980, Strengthening by surface damage in metastable tetragonal zirconia, Journal of the American Ceramic Society, 63, 117, 10.1111/j.1151-2916.1980.tb10671.x
Jemt, 1993, Implant treatment in resorbed edentulous upper jaws, Clinical Oral Implants Research, 4, 187, 10.1034/j.1600-0501.1993.040404.x
Jemt, 1994, Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report, Clinical Oral Implants Research, 5, 142, 10.1034/j.1600-0501.1994.050304.x
Jemt, 1990, 3-year follow-up study of early single implant restorations ad modum Brånemark, The International Journal of Periodontics and Restorative Dentistry, 10, 341
Jung, 2007, In vitro color changes of soft tissues caused by restorative materials, International Journal of Periodontics and Restorative Dentistry, 27, 251
Keith, 1994, Zirconia brackets, American Journal of Orthodontics and Dentofacial Orthopedics, 106, 605, 10.1016/S0889-5406(94)70085-0
Kelly, 2008, Stabilized zirconia as a structural ceramic, Dental Materials, 24, 289, 10.1016/j.dental.2007.05.005
Kiliaridis, 1993, The relationship between maximal bite force, bite force endurance, and facial morphology during growth. A cross-sectional study, Acta Odontologica Scandinavica, 51, 323, 10.3109/00016359309040583
Kohal, 2004, A zirconia implant-crown system, International Journal of Periodontics and Restorative Dentistry, 24, 147
Kohal, 2002, Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants, International Journal of Prosthodontics, 15, 189
Kohal, 2010, Alumina-reinforced zirconia implants, Clinical Oral Implants Research, 10.1111/j.1600-0501.2010.01954.x
Körber, 1983, Maximale Kaukraft als Berechnungsfaktor zahntechnischer Konstruktionen, Dental-Labor, 31, 55
Kosmac, 1999, The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic, Dental Materials, 15, 426, 10.1016/S0109-5641(99)00070-6
Mailath, 1989, Die Knochenresorption an der Eintrittstelle osseointegrierter Implantate - ein biomechanisches Phanomen. Eine Finite-Element-Studie, Zeitschrift für Stomatologie, 86, 207
Manicone, 2007, An overview of zirconia ceramics, Journal of Dentistry, 35, 819, 10.1016/j.jdent.2007.07.008
Mellinghoff, 2006, Erste klinische Ergebnisse zu dentalen Schraubenimplantaten aus Zirkonoxid, Zeitschrift für Zahnärztliche Implantologie, 22, 288
Meyenberg, 1995, Zirconia posts, Journal of Esthetic Dentistry, 7, 73, 10.1111/j.1708-8240.1995.tb00565.x
Oblak, 2004, Fracture resistance and reliability of new zirconia posts, Journal of Prosthetic Dentistry, 91, 342, 10.1016/j.prosdent.2004.01.009
Oliva, 2007, One-year follow-up of first consecutive 100 zirconia dental implants in humans, he International Journal of Oral & Maxillofacial Implants, 22, 430
Oliva, 2010, Five-year success rate of 831 consecutively placed Zirconia dental implants in humans, he International Journal of Oral & Maxillofacial Implants, 25, 336
Osborn, 1990, Anterior component of force, American Journal of Orthodontics and Dentofacial Orthopedics, 97, 24A, 10.1016/S0889-5406(08)80101-1
Papanagiotou, 2006, In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics, Journal of Prosthetic Dentistry, 96, 154, 10.1016/j.prosdent.2006.08.004
Reitz, 1973, A cephalometric study of tooth position as related to facial structure in profiles of human beings, Journal of Prosthetic Dentistry, 29, 157, 10.1016/0022-3913(73)90108-X
Rho, 1993, Young's modulus of trabecular and cortical bone material, Journal of Biomechanics, 26, 111, 10.1016/0021-9290(93)90042-D
Sailer, 2007, Five-year clinical results of zirconia frameworks for posterior fixed partial dentures, International Journal of Prosthodontics, 20, 383
Sato, 1985, Transformation of yttria-doped tetragonal ZrO2 polycrystals by annealing in water, Journal of the American Ceramic Society, 68, 356, 10.1111/j.1151-2916.1985.tb15239.x
Scarano, 2004, Bacterial adhesion on commercially pure titanium and zirconium oxide disks, Journal of Periodontology, 75, 292, 10.1902/jop.2004.75.2.292
Schindler, 1998, Feedback control during mastication of solid food textures - a clinical-experimental study, Journal of Prosthetic Dentistry, 80, 330, 10.1016/S0022-3913(98)70134-9
Schwickerath, 1988, Vollkeramische Brücken - Gerüste aus Kern- oder Hartkernmassen, Dental-Labor, 36, 1081
Shimizu, 1993, Time-dependent changes in the mechanical properties of zirconia ceramic, Journal of Biomedical Materials Research, 27, 729, 10.1002/jbm.820270605
Sicilia, 2008, Titanium allergy in dental implant patients, Clinical Oral Implants Research, 19, 823, 10.1111/j.1600-0501.2008.01544.x
Silva, 2009, Reliability of one-piece ceramic implant, Journal of Biomedical Materials Research Part B: Applied Biomaterials, 88, 419, 10.1002/jbm.b.31113
Suarez, 2004, Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs, International Journal of Prosthodontics, 17, 35
Swain, 1989, Metastability of the martensitic transformation in a 12mol% ceria-zirconia alloy, Journal of the American Ceramic Society, 72, 1358, 10.1111/j.1151-2916.1989.tb07652.x
Tinschert, 2006, Bruchfestigkeit zirkonoxidbasierter Seitenzahnbrücken. Eine vergleichende In-vitro-Studie, Quintessenz, 57, 867
Tschernitschek, 2005, Nonalloyed titanium as a bioinert metal - a review, Quintessence International, 36, 523
Volz, 2004, Metal-free reconstructions with zirconia implants and zirconia crowns, Quintessence Journal of Dental Technology, 2, 324
Vult von Steyern, 2005, All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems, Swedish Dental Journal Supplement, 173, 1
Wenz, 2008, Osseointegration and clinical success of zirconia dental implants, International Journal of Prosthodontics, 21, 27