The capillary adhesion technique: a versatile method for determining the liquid adhesion force and sample stiffness

Beilstein Journal of Nanotechnology - Tập 6 - Trang 11-18
Daniel Gandyra1, Stefan Walheim1, Stanislav N. Gorb2, Wilhelm Barthlott3, Thomas Schimmel4
1Institute of Applied Physics and Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT), 76128 Karlsruhe, Germany
2Zoological Institute, University of Kiel, 24118 Kiel, Germany.
3Nees Institute for Biodiversity of Plants, University of Bonn, 53115 Bonn, Germany.
4Institute of Applied Physics and Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT), 76128 Karlsruhe, Germany ; Institute of Nanotechnology (INT), Karlsruhe Institute of Technology (KIT), 76021 Karlsruhe, Germany.

Tóm tắt

We report a novel, practical technique for the concerted, simultaneous determination of both the adhesion force of a small structure or structural unit (e.g., an individual filament, hair, micromechanical component or microsensor) to a liquid and its elastic properties. The method involves the creation and development of a liquid meniscus upon touching a liquid surface with the structure, and the subsequent disruption of this liquid meniscus upon removal. The evaluation of the meniscus shape immediately before snap-off of the meniscus allows the quantitative determination of the liquid adhesion force. Concurrently, by measuring and evaluating the deformation of the structure under investigation, its elastic properties can be determined. The sensitivity of the method is remarkably high, practically limited by the resolution of the camera capturing the process. Adhesion forces down to 10 µN and spring constants up to 2 N/m were measured. Three exemplary applications of this method are demonstrated: (1) determination of the water adhesion force and the elasticity of individual hairs (trichomes) of the floating fernSalvinia molesta. (2) The investigation of human head hairs both with and without functional surface coatings (a topic of high relevance in the field of hair cosmetics) was performed. The method also resulted in the measurement of an elastic modulus (Young’s modulus) for individual hairs of 3.0 × 105N/cm2, which is within the typical range known for human hair. (3) Finally, the accuracy and validity of the capillary adhesion technique was proven by examining calibrated atomic force microscopy cantilevers, reproducing the spring constants calibrated using other methods.

Từ khóa


Tài liệu tham khảo

10.1002/adma.200904411

10.1088/1748-3182/2/4/S02

10.1098/rsta.2009.0022

10.1016/j.pmatsci.2008.07.003

10.1016/j.pmatsci.2010.04.003

10.1109/MEMSYS.2002.984306

10.1063/1.1812011

10.1063/1.3081420

10.2514/1.9104

10.1021/am9001937

10.1039/b917861a

10.1039/c3ta10225d

10.1007/978-1-4020-6697-9_7

10.1016/j.colsurfa.2011.01.033

10.1016/j.crme.2011.11.002

10.1006/jcis.1997.4855

10.1021/la901616x

10.1021/la102545z

10.1016/j.cis.2008.10.002

10.1093/icb/42.6.1127

Jiao, 2000, Journal of Experimental Biology, 203, 1887, 10.1242/jeb.203.12.1887

10.1073/pnas.0506328102

10.3762/bjnano.5.95

Bronstein, 2007, Handbook of Mathematics

Adamson, 1997, Physical Chemistry of Surfaces

10.1007/978-3-642-12894-3

Robbins, 2002, Chemical and Physical Behavior of Human Hair, 10.1007/b97447

Naruse, 1971, Geriatr. Soc., 19, 308, 10.1111/j.1532-5415.1971.tb05371.x

Johri, 1982, Med., Sci. Law., 22, 63, 10.1177/002580248202200112