The Effect of Temperature Elevation During Discontinuous Use of Rotatory Burrs in the Correction of Hallux Valgus
Tài liệu tham khảo
Eriksson, 1984, The effect of heat on bone regeneration, J Oral Maxillofac Surg, 42, 705, 10.1016/0278-2391(84)90417-8
Eriksson, 1984, Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals, Acta Orthop Scand, 55, 629, 10.3109/17453678408992410
Matthews, 1984, The thermal effects of skeletal fixation-pin insertion in bone, J Bone Joint Surg Am, 66, 1077, 10.2106/00004623-198466070-00015
Matthews, 1972, Temperatures measured in human cortical bone when drilling, J Bone Joint Surg Am, 54, 297, 10.2106/00004623-197254020-00008
Toksvig-Larsen, 1990, An internally cooled saw blade for bone cuts. Lower temperatures in 30 knee arthroplasties, Acta Orthop Scand, 61, 321, 10.3109/17453679008993526
Eichler, 1972, Influence of temperature on the compact bone substance during drilling, thread cutting and insertion of bone screws, Z Orthop Ihre Grenzgeb, 110, 909
Kreisler, 2003, Temperature changes induced by 809-nm GaA1As laser at the implant-bone interface during simulated surface decontamination, Clin Oral Implants Res, 14, 91, 10.1034/j.1600-0501.2003.140112.x
Weinlaender, 1999, Bone growth around dental implants, Dent Clin North Am, 35, 585, 10.1016/S0011-8532(22)00860-6
Brisman, 1996, The effect of speed, pressure, and time on bone temperature during the drilling of implant sites, Int J Oral Maxillofac Implants, 11, 35
Rafel, 1962, Temperature changes during high-speed drilling on bone, J Oral Surg Anesth Hosp Dent Serv, 20, 475
Call, 1978, Thermal injury from mastoid bone burrs, Ann Otol Rhinol Laryngol, 87, 43, 10.1177/000348947808700109
Wikenheiser, 1995, Thermal response and torque resistance of five cortical half-pins under simulated insertion technique, J Orthop Res, 13, 615, 10.1002/jor.1100130418
Brisman, 1996, The effect of speed, pressure, and time on bone temperature during the drilling of implant sites, Int J Oral Maxillofac Implants, 11, 35
Abouzgia, 1997, Temperature rise during drilling through bone, Int J Oral Maxillofac Implants, 12, 342
Cordioli, 1997, Heat generation during implant site preparation, Int J Oral Maxillofac Implants, 12, 186
Ercoli, 2004, The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants, Int J Oral Maxillofac Implants, 19, 335
Natali, 1996, Orthopaedic bone drills-can be improved? Temperature changes near the drilling face, J Bone Joint Surg Br, 78, 357, 10.1302/0301-620X.78B3.0780357
Firoozbakhsh, 2003, Heat generation during ulnar osteotomy with microsagittal saw blades, Iowa Orthop J, 23, 46
Reigenwirtz, 1997, Influence of different parameters on bone heating and drilling time in implantology, Clin Oral Implants Res, 8, 189, 10.1034/j.1600-0501.1997.080305.x
Sharawy, 2002, Heat generation during implant drilling, J Oral Maxillofac Surg, 60, 1160, 10.1053/joms.2002.34992
Rattner, 1999, Future directions in innovative minimally invasive surgery, Lancet, 353, SI12, 10.1016/S0140-6736(99)90416-6
Baumgart, 1998, Indications and technique of bone cutting, Chirurg, 69, 1188, 10.1007/s001040050556
Chalk, 1992, Minimal incision surgery, Foot Ankle, 13, 157, 10.1177/107110079201300308
Solomon, 1991, Complications in minimal incision surgery, Clin Podiatr Med Surg, 8, 221
Isham, 1991, The Reverdin-Isham procedure for the correction of hallux abducto valgus. A distal metatarsal osteotomy procedure, Clin Podiatr Med Surg, 8, 81
Hardy, 1951, Observations on hallux valgus, J Bone Joint Surg Br, 33, 376, 10.1302/0301-620X.33B3.376
Coughlin, 1999, Hallux valgus, 175
White, 1977, The four biomechanical stages of fracture repair, J Bone Joint Surg Am, 59, 188, 10.2106/00004623-197759020-00009
Gehrke, 1993, The Fluoroscan imaging system in foot and ankle surgery, Foot Ankle, 14, 545, 10.1177/107110079301400912
Tehemar, 1999, Factors affecting heat generation during implant site preparation, Int J Oral Maxillofac Implants, 14, 127
Berman, 1984, Thermal induced bone necrosis in rabbits. Relation to implant failure in humans, Clin Orthop Jun, 186, 284
Bonfield, 1992, The temperature dependence of the deformation of bone, J Biomech, 25, 11
Yacker, 1996, The effect of irrigation on osteotomy depth and bur diameter, Int J Oral Maxillofac Implants, 11, 634
Wiggins, 1976, Drilling of bone, J Biomech, 9, 553, 10.1016/0021-9290(76)90095-6
Eriksson, 1982, Thermal injury to bone. A vital-microscopic description of heat effects, Int J Oral Surg, 11, 115, 10.1016/S0300-9785(82)80020-3
Krause, 1982, Temperature elevations in orthopaedic cutting operations, J Biomech, 15, 267, 10.1016/0021-9290(82)90173-7
Tetsch, 1974, Development of raised temperature after osteotomies, J Maxillofac Surg, 2, 141, 10.1016/S0301-0503(74)80030-5
Park, 1998, The influence of active shear or compressive motion on fracture-healing, J Bone Joint Surg Am, 80, 868, 10.2106/00004623-199806000-00011
Sammarco, 2001, Complications after surgery of the hallux, Clin Orthop Oct, 391, 59, 10.1097/00003086-200110000-00008