The BHU bicentric bipolar prosthesis in fracture neck femur in active elderly
Tóm tắt
55 BHU bicentric bipolar hemiarthroplasties were reviewed after a mean follow up of 4 years (range 1–5 years). Patients with displaced subcapital fractures were selected for operation on the basis of good mobility before the fracture. Object of the study was to see the efficacy of BHU bipolar prostheses and functional outcome. There were no incidences of dislocation. Modified Harris hip scoring system scoring system was used which included sitting crosslegged and squatting in view of the sociocultural needs of the patients of Indian subcontinent. Modified Harris hip scoring system 89% had a good or excellent result and 94% had no or only occasional pain. Majority of the patients returned to their prefracture activity. Thus at follow up of 4 year the BHU bicentric bipolar prosthesis has been shown to be a good option for intracapsular fractures of neck femur with encouraging results.
Tài liệu tham khảo
Hunter GA: Should we abandon primary prosthetic replacement for fresh displaced fractures of the femoral neck?. Clin Orthop. 1980, 152: 158-164.
Bray TJ, Smith-Hoefer E, Hooper A, Timmerman L: The displaced femoral neck fracture. Internal fixation versus bipolar endoprosthesis: Results of a prospective, randomized comparison. Clin Orthop. 1988, 230: 127-140.
Salvate EP, Wilson PD: Long-term results of femoral head replacement. J Bone Joint Surg [Am]. 1974, 55: 516-520.
Messieh M, Mattingly D, Turner R, Scott R, Fox J, Slater J: Wear debris from bipolar femoral neck-cup impingement: A cause of femoral stem loosening. J of Arthroplasty. 1994, 9: 89-93. 10.1016/0883-5403(94)90142-2.
Kovayashi S, Takaoka K, Tsukada A: Polyethylene wear from femoral bipolar neck-cup impingement as a cause of femoral prosthetic loosening. Arch Orthop Trauma Surg. 1998, 117: 390-391. 10.1007/s004020050274.
Fischer-Cripps , Anthony C, Lawn , Brian R: Stress Analysis of Contact Deformation in Quasi-Plastic Ceramics. Journal of the American Ceramic Society. 1996, 84: 1844-1850.
Merle d'Aubigné R, Postel M: Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954, 36A: 451-475.
Kuokkanen HOM, Suominen PK, Korkala OL: The outcome of femoral neck fractures. Int Orthop. 1990, 14: 377-380. 10.1007/BF00182648.
LaBelle LW, Colwill IE, Swanson AB: Bateman bipolar hip arthroplasty for femoral neck fractures. A five- to ten-year follow-up study. Clin Orthop. 1990, 251: 20-25.
Phillips TW: Thompson hemiarthroplasty and acetabular erosion. J Bone Joint Surg [Am]. 1989, 71: 913-917.
Kofoed H, Ko fod I: Moore prosthesis in the treat ment of fresh femoral neck Fractures. Injury. 1983, 14: 531-540. 10.1016/0020-1383(83)90057-8.
D'Arcy I, Devas M: Treatment of fractures of the femoral neck by replacement with the Thompson prosthesis. J Bone Joint Surg (Br). 1976, 58: 279-286.
Bochner RM, Pellici PM, Lyden JP: Bipolar hemiarthroplasty for fracture of the femoral neck. J Bone Joint Surg [Am]. 1988, 70: 1001-1010.
Wetherall RG, Hinves BL: The Hastings bipolar hemiarthroplasty for subcapital fracture of the femoral neck: A 10-year prospective study. J Bone Joint Surg [Br]. 1990, 72: 788-793.
Kwok DC, Cruess RL: A retrospective study of Moore and Thompson hemiarthroplasty. A review of 599 surgical cases and an analysis of the technical complications. Clin Orthop. 1982, 169: 179-185.
Anderson PR, Milgram JW: Dislocation and component separation of the Bateman hip endoprosthesis. JAMA. 1978, 240: 2079-2080. 10.1001/jama.240.19.2079.
Barmada R, Siegel IM: Post-operative separation of the femoral and acetabular components of a single-assembly total hip (Bateman) replacement. J Bone Joint Surg [Am]. 1979, 61: 777-778.
Krein SW, Chao EVS: Biomechanics of bipolar hip endoprosthesis. J Orthop Res. 1984, 2: 356-368. 10.1002/jor.1100020408.
Prior written consent was taken from the patient for publication of picture in the article.