Hip and knee arthroplasties are frequently complicated by the need for allogeneic blood transfusions. This survey was conducted to assess the current use of perioperative blood-saving measures and to compare it with prior results. All departments of orthopaedic surgery at Dutch hospitals were sent a follow-up survey on perioperative blood-saving measures, and data were compared to the results of two surveys conducted 5 and 10 years earlier. The response rate was 94 out of 108 departments (87 %). Most departments used erythropoietin prior to hip and knee replacements at the expense of preoperative autologous blood donation. The use of intraoperative autologous retransfusion in revision hip (56 vs. 54 %) as well as revision knee arthroplasty (26 vs. 24 %), was virtually unchanged. Postoperative autologous retransfusion is still used by the majority of departments after both primary arthroplasty and revision of hip (58/53 %) and knee (65/61 %). Currently, just as in 2007, the majority of Dutch orthopaedic departments uses erythropoietin, normothermia and postoperative autologous retransfusion with hip and knee arthroplasty. Intraoperative retransfusion is used mainly with hip revision arthroplasty. Other effective blood management modalities such as tranexamic acid have not been widely implemented.

Tài liệu tham khảo

Goodnough LT (2003) Risks of blood transfusion. Crit Care Med 31:S678–S686 Shander A, Javidroozi M, Ozawa S, Hare GM (2011) What is really dangerous: anaemia or transfusion? Br J Anaesth 107 Suppl 1:i41–i59 Bierbaum BE, Callaghan JJ, Galante JO, Rubash HE, Tooms RE, Welch RB (1999) An analysis of blood management in patients having a total hip or knee arthroplasty. J Bone Jt Surg Am 81:2–10 Slappendel R, Dirksen R, Weber EW, van der Schaaf DB (2003) An algorithm to reduce allogeneic red blood cell transfusions for major orthopaedic surgery. Acta Orthop Scand 74:569–575 Blumberg N (1997) Allogeneic transfusion and infection: economic and clinical implications. Semin Hematol 34:34–40 Innerhofer P, Klingler A, Klimmer C, Fries D, Nussbaumer W (2005) Risk for postoperative infection after transfusion of white blood cell-filtered allogeneic or autologous blood components in orthopaedic patients undergoing primary arthroplasty. Transfusion 45:103–110 Horstmann WG, Ettema HB, Verheyen CCPM (2010) Dutch orthopaedic blood-management surveys 2002 and 2007: an increasing use of blood saving measures. Arch Orthop Trauma Surg 130(1):55–59 Carson JL, Carless PA, Hebert PC (2012) Transfusion thresholds and other strategies for guiding allogeneic red blood cell transfusion. Cochrane Database Syst Rev 4:CD002042 Harkness M, Palmer JB, Watson D, Walsh TS (2008) A questionnaire-based survey of perioperative blood conservation practice for revision hip arthroplasty in Scotland. Transfus Med 18(5):296–301 Voorn VMA, Marang-van de Mheen PJ, Wentink MM, So-Osman C, Vliet Vlieland TPM, Koopman-Van Gemert AWMM, Nelissen RGHH, Van Bodegom-Vos L, the LISBOA study group (2013) Frequent use of blood-saving measures in elective orthopaedic surgery: a 2012 Dutch blood management survey. BMC Musculoskelet Disord 14:230 Henry DA, Carless PA, Moxey AJ, O’Connell D, Forgie MA, Wells PS, Fergusson D (2002) Pre-operative autologous donation for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev (2):CD003602 Centraal Begeleidings Orgaan (2011) Guideline Blood Transfusion Earnshaw P (2001) Blood conservation in orthopaedic surgery: the role of epoetin alfa. Int Orthop 25:273–278 Moonen AF, Thomassen BJ, Knoors NT, van Os JJ, Verburg AD, Pilot P (2008) Pre-operative injections of epoetin-alpha versus post-operative retransfusion of autologous shed blood in total hip and knee replacement: a prospective randomised clinical trial. J Bone Jt Surg Br 90(8):1079–1083 Weber EW, Hémon Y, Mähler S, Dalén T, Rouwet E, van Os J, Vosmaer A, van der Ark P (2005) Effects of epoetin alfa on blood transfusions and postoperative recovery in orthopaedic surgery: the European Epoetin Alfa Surgery Trial (EEST). Eur J Anaesthesiol 22(4):249–257 Saleh E, McClelland DB, Hay A, Semple D, Walsh TS (2007) Prevalence of anaemia before major joint arthroplasty and the potential impact of preoperative investigation and correction on perioperative blood transfusions. Br J Anaesth 99:801–808 Horstmann WG, Swierstra MJ, Ohanis D, Castelein RM, Kollen BJ, Verheyen CC (2013) Reduction of blood loss with the use of a new combined intra-operative and post-operative autologous blood transfusion system compared with no drainage in primary total hip replacement. Bone Jt J 95-B(5):616–622 Huët C, Salmi LR, Fergusson D, Koopman-van Gemert AW, Rubens F, Laupacis A (1999) A meta-analysis of the effectiveness of cell salvage to minimize perioperative allogeneic blood transfusion in cardiac and orthopaedic surgery. International study of perioperative transfusion (ISPOT) investigators. Anesth Analg 89(4):861–869 Carless PA, Henry DA, Moxey AJ, O’Connell D, Brown T, Fergusson DA (2010) Cell salvage for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev (3):CD001888 Corazza ML, Hranchook AM (2000) Massive blood transfusion therapy. AANA J 68(4):311–314 Eastridge BJ, Malone D, Holcomb JB (2006) Early predictors of transfusion and mortality after injury: a review of the data-based literature. J Trauma 60(6 Suppl):S20–S25 Society of Thoracic Surgeons Blood Conservation Guideline Task Force, Ferraris VA, Ferraris SP, Saha SP, Hessel EA 2nd, Haan CK, Royston BD, Bridges CR, Higgins RS, Despotis G, Brown JR, Society of cardiovascular anesthesiologists special task force on blood transfusion, Spiess BD, Shore-Lesserson L, Stafford-Smith M, Mazer CD, Bennett-Guerrero E, Hill SE, Body S (2007) Perioperative blood transfusion and blood conservation in cardiac surgery: the Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists clinical practice guideline. Ann Thorac Surg 83(5 Suppl):S27–S86 Bryson GL, Laupacis A, Wells GA (1998) Does acute normovolemic hemodilution reduce perioperative allogeneic transfusion? A meta-analysis. The international study of perioperative transfusion. Anesth Analg 86(1):9–15 Höhn L, Schweizer A, Licker M, Morel DR (2002) Absence of beneficial effect of acute normovolemic hemodilution combined with aprotinin on allogeneic blood transfusion requirements in cardiac surgery. Anesthesiology 96(2):276–282 Ramnath AN, Naber HR, de Boer A, Leusink JA (2003) No benefit of intraoperative whole blood sequestration and auto transfusion during coronary artery bypass grafting: results of a randomized clinical trial. J Thorac Cardiovasc Surg 125(6):1432–1437 Davies L, Brown TJ, Haynes S, Payne K, Elliott RA, McCollum C (2006) Cost-effectiveness of cell salvage and alternative methods of minimising perioperative allogeneic blood transfusion: a systematic review and economic model. Health Technol Assess 10(44):iii–iv ix–x, 1–210 Carless PA, Henry DA, Anthony DM (2003) Fibrin sealant use for minimising peri-operative allogeneic blood transfusion. Cochrane Database Syst Rev (2):CD004171 Carless PA, Anthony DM, Henry DA (2002) Systematic review of the use of fibrin sealant to minimize perioperative allogenic blood transfusion. Br J Surg 89:695–703 Patel S, Rodriquez-Merchan EC, Haddad FS (2010) The use of fibrin glue in surgery of the knee. J Bone Jt Surg Br 92:1325–1331 Thoms RJ, Marwin SE (2009) The role of fibrin sealants in orthopaedic surgery. J Am Acad Orthop Surg 17:727–736 Henry DA, Carless PA, Moxey AJ, O’Connell D, Stokes BJ, Fergusson DA, Ker K (2011) Anti-fibrinolytic use for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev (3):CD001886 Parker MJ, Livingstone V, Clifton R, McKee A (2007) Closed suction surgical wound drainage after orthopaedic surgery. Cochrane Database Syst Rev (3):CD001825 Wong CJ, Vandervoort MK, Vandervoort SL, Donner A, Zou G, MacDonald JK, Freedman J, Karkouti K, MacDonald SJ, Feagan BG (2007) A cluster-randomized controlled trial of a blood conservation algorithm in patients undergoing total hip joint arthroplasty. Transfusion 47(5):832–841 Pierson JL, Hannon TJ, Earles DR (2004) A blood-conservation algorithm to reduce blood transfusions after total hip and knee arthroplasty. J Bone Joint Surg Am 86-A(7):1512–1518