Tailoring surface properties, biocompatibility and corrosion behavior of stainless steel by laser induced periodic surface treatment towards developing biomimetic stents

Surfaces and Interfaces - Tập 34 - Trang 102365 - 2022
Muhammad Saqib1,2, Natalia Beshchasna1, Riccardo Pelaccia3, Anton Roshchupkin4, Ilya Yanko4, Yevheniia Husak4,5, Sergiy Kyrylenko4, Barbara Reggiani3,6, Gianaurelio Cuniberti2, Maksym Pogorielov4,7,8, Joerg Opitz1,2, Leonardo Orazi3,9
1Fraunhofer Institute for Ceramic Technologies and Systems IKTS, Maria-Reiche-Strasse 2, Dresden 01109, Germany
2Institute of Materials Science and Max Bergmann Center of Biomaterials, Technische Universität Dresden, Dresden 01062, Germany
3Department of Sciences and Methods for Engineering, University of Modena and Reggio Emilia, Via Giovanni Amendola, 2, 42122 Reggio Emilia RE
4Biomaterials Research Center, Sumy State University, 31 Sanatorna St, Sumy 40018, Ukraine
5Faculty of Chemistry, Silesian University of Technology, Gliwice 44-100, Poland
6InterMech MO.RE., Tecnopolo di Reggio Emilia, 1 Piazzale Europa, Reggio Emilia 42124, Italy
7Institute of Atomic Physics and Spectroscopy, University of Latvia, 3 Jelgavas iela, Riga LV-1004, Latvia
8NanoPrime, 25 Metalowcow St, Dedice 39-200, Poland
9En&Tech, Tecnopolo di Reggio Emilia, 1 Piazzale Europa, Reggio Emilia 42124, Italy

Tài liệu tham khảo

Doenst, 2019, PCI and CABG for treating stable coronary artery disease: JACC review topic of the week, J. Am. Coll. Cardiol., 73, 964, 10.1016/j.jacc.2018.11.053 Brown, 2018, Last nail in the coffin for PCI in a stable angina?, Lancet, 391, 3, 10.1016/S0140-6736(17)32757-5 Al-Lamee, 2019, Percutaneous coronary intervention for stable coronary artery disease, Heart, 105, 11, 10.1136/heartjnl-2017-312755 Sigwart, 1987, Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty, N. Engl. J. Med., 316, 701, 10.1056/NEJM198703193161201 Holmes, 2002, Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) trial, Circulation, 106, 1243, 10.1161/01.CIR.0000028335.31300.DA Serruys P.W., Strauss B.H., Beatt K.J., et al. (1991) Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery Stent. 324:13–17. doi:10.1056/NEJM199101033240103. Rossini, 2010, Long-term outcomes in patients undergoing percutaneous coronary intervention with drug-eluting stents, Expert Rev. Pharmacoecon. Outcomes Res., 10, 49, 10.1586/erp.10.1 Bertrand, 1998, Biocompatibility aspects of new stent technology, J. Am. Coll. Cardiol., 32, 562, 10.1016/S0735-1097(98)00289-7 SO, 2001, Bench to bedside: the development of rapamycin and its application to stent restenosis, Circulation, 104, 24 Menown, 2010, The platinum chromium element stent platform: from alloy, to design, to clinical practice, Adv. Ther., 27, 129, 10.1007/s12325-010-0022-9 Colombo, 2003, Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions, Circulation, 108, 788, 10.1161/01.CIR.0000086926.62288.A6 El-Hayek, 2014, Meta-analysis of randomized clinical trials comparing short-term versus long-term dual antiplatelet therapy following drug-eluting stents, Am. J. Cardiol., 114, 236, 10.1016/j.amjcard.2014.04.035 Holmvang, 2013, JACC Cardiovasc. Interv., 6, 548, 10.1016/j.jcin.2012.12.129 Shahryari, 2010, The response of fibrinogen, platelets, endothelial and smooth muscle cells to an electrochemically modified SS316LS surface: towards the enhanced biocompatibility of coronary stents, Acta Biomater., 6, 695, 10.1016/j.actbio.2009.07.007 Yang, 2010, The covalent immobilization of heparin to pulsed-plasma polymeric allylamine films on 316L stainless steel and the resulting effects on hemocompatibility, Biomaterials, 31, 2072, 10.1016/j.biomaterials.2009.11.091 Saqib, 2021, Evaluation of in vitro corrosion behavior of titanium oxynitride coated stainless steel stents, IEEE Access, 9, 59766, 10.1109/ACCESS.2021.3072597 Beshchasna, 2019, Surface evaluation of titanium oxynitride coatings used for developing layered cardiovascular stents, Mater. Sci. Eng. C, 99, 405, 10.1016/j.msec.2019.01.131 Zhang, 2014, Surface modification of implanted cardiovascular metal stents: from antithrombosis and antirestenosis to endothelialization, J. Biomed. Mater. Res., 102, 588, 10.1002/jbm.a.34714 Dong, 2022, Surface engineering and the application of laser-based processes to stents—a review of the latest development, Bioact. Mater., 10, 159, 10.1016/j.bioactmat.2021.08.023 Bonse, 2020, Quo vadis LIPSS?—recent and future trends on laser-induced periodic surface structures, Nanomaterials, 10, 1, 10.3390/nano10101950 Kotsiuba, 2021, Bitmap and vectorial hologram recording by using femtosecond laser pulses, Sci. Rep., 111, 1 Orazi, 2015, Nonlinear laser lithography to control surface properties of stainless steel, CIRP Ann., 64, 193, 10.1016/j.cirp.2015.04.038 Kunz, 2020, Tribological performance of metal-reinforced ceramic composites selectively structured with femtosecond laser-induced periodic surface structures, Appl. Surf. Sci., 499, 10.1016/j.apsusc.2019.143917 Gnilitskyi, 2019, Tribological properties of high-speed uniform femtosecond laser patterning on stainless steel, Lubricants, 7, 10.3390/lubricants7100083 Gnilitskyi, 2019, Cell and tissue response to nanotextured Ti6Al4V and Zr implants using high-speed femtosecond laser-induced periodic surface structures, Nanomedicine, 21 Gräf, 2020, Formation of laser-induced periodic surface structures on different materials: fundamentals, properties and applications, Adv. Opt. Technol., 9, 11, 10.1515/aot-2019-0062 Stratakis, 2020, Laser engineering of biomimetic surfaces, Mater. Sci. Eng. R Rep., 141, 10.1016/j.mser.2020.100562 Mohammed, 2014, Surface modifications of titanium materials for developing corrosion behavior in human body environment: a review, Procedia Mater. Sci., 6, 1610, 10.1016/j.mspro.2014.07.144 Yue T.M., Yu J.K., Mei Z., Man H.C. (2002) Excimer laser surface treatment of Ti-6Al-4V alloy for corrosion resistance enhancement. Singh, 2011, Electrochemical and mechanical behavior of laser processed Ti-6Al-4V surface in Ringer's physiological solution, J. Mater. Sci. Mater. Med., 22, 1787, 10.1007/s10856-011-4362-z Geetha, 2004, Microstructural and corrosion evaluation of laser surface nitrided Ti-13Nb-13Zr alloy, Surf. Eng., 20, 68, 10.1179/026708404225010595 Jang, 2018, Inhibition of bacterial adhesion on nanotextured stainless steel 316L by electrochemical etching, ACS Biomater. Sci. Eng., 4, 90, 10.1021/acsbiomaterials.7b00544 de Lara, 2016, Corrosion resistance of laser patterned ultrahydrophobic aluminium surface, Mater. Lett., 184, 100, 10.1016/j.matlet.2016.08.022 Ramachandran, 2015, Coupling of surface energy with electric potential makes superhydrophobic surfaces corrosion-resistant, Phys. Chem. Chem. Phys., 17, 24988, 10.1039/C5CP04462F Qiu, 2019, Biomimetic engineering endothelium-like coating on cardiovascular stent through heparin and nitric oxide-generating compound synergistic modification strategy, Biomaterials, 207, 10, 10.1016/j.biomaterials.2019.03.033 Barrere F., Van Blitterswijk C.A., De Groot K., Layrolle P. (2002) Nucleation of biomimetic Ca-P coatings on Ti6Al4V from a SBF Â 5 solution: influence of magnesium. Cui, 2013, Biomimetic coating of magnesium alloy for enhanced corrosion resistance and calcium phosphate deposition, Acta Biomater., 9, 8650, 10.1016/j.actbio.2013.06.031 Martínez-Calderon, 2020, Biomimetic hierarchical micro/nano texturing of TiAlV alloys by femtosecond laser processing for the control of cell adhesion and migration, Phys. Rev. Mater., 4 Liang, 2016, Biomimetic cardiovascular stents for in vivo re-endothelialization, Biomaterials, 103, 170, 10.1016/j.biomaterials.2016.06.042 Bonse, 2021, Ten open questions about laser-induced periodic surface structures, Nanomaterials, 11, 10.3390/nano11123326 Selvakumar, 2010, Effect of substrate roughness on the apparent surface free energy of sputter deposited superhydrophobic polytetrafluoroethylene coatings: a comparison of experimental data with different theoretical models, J. Appl. Phys., 108, 10.1063/1.3456165 Kozbial, 2014, Study on the surface energy of graphene by contact angle measurements, Langmuir, 30, 8598, 10.1021/la5018328 Song, 2019, Interaction of surface energy components between solid and liquid on wettability, and its application to textile anti-wetting finish, Polymers, 11, 10.3390/polym11030498 Zhang, 2019, Binary liquid mixture contact-angle measurements for precise estimation of surface free energy, Langmuir, 35, 12317, 10.1021/acs.langmuir.9b01252 Martinez, 2020, Surface roughness of titanium disks influences the adhesion, proliferation and differentiation of osteogenic properties derived from human, Int. J. Implant Dent., 6, 10.1186/s40729-020-00243-5 Chinga, 2003, Paper surface characterisation by laser profilometry and image analysis, Microsc. Anal., 96, 21 Kyrylenko, 2021, Effects of the sources of calcium and phosphorus on the structural and functional properties of ceramic coatings on titanium dental implants produced by plasma electrolytic oxidation, Mater. Sci. Eng. C, 119, 10.1016/j.msec.2020.111607 Palencia, 2017, Surface free energy of solids by contact angle measurements, J. Sci. Technol. Appl., 2, 84, 10.34294/j.jsta.17.2.17 Sun, 2018, Wetting behavior of four polar organic solvents containing one of three lithium salts on a lithium-ion-battery separator, J. Colloid Interface Sci., 529, 582, 10.1016/j.jcis.2018.06.044 Lv, 2015, Stability and corrosion resistance of superhydrophobic surface on oxidized aluminum in NaCl aqueous solution, Appl. Surf. Sci., 333, 163, 10.1016/j.apsusc.2015.02.012 Wang, 2014, Superhydrophobic membranes on metal substrate and their corrosion protection in different corrosive media, Appl. Surf. Sci., 305, 603, 10.1016/j.apsusc.2014.03.142 Wang, 2022, Endothelial cell distribution after flow exposure with two stent struts placed in different angles, Front. Physiol., 12, 10.3389/fphys.2021.733547