Supplement to the 2004 update of the AAPM Task Group No. 43 Report

Medical Physics - Tập 34 Số 6Part1 - Trang 2187-2205 - 2007
Mark J. Rivard1, Wayne M. Butler, Larry A. DeWerd, M. Saiful Huq, Geoffrey S. Ibbott, Ali S. Meigooni, Christopher S. Melhus, Michael G. Mitch, Ravinder Nath, Jeffrey F. Williamson
1Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111, USA. [email protected]

Tóm tắt

Since publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG‐43U1), several new low‐energy photon‐emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical use as of January 10, 2005, and are posted on the Joint AAPM/RPC Brachytherapy Seed Registry. Consequently, the AAPM has prepared this supplement to the 2004 AAPM TG‐43 update. This paper presents the AAPM‐approved consensus datasets for these sources, and includes the following sources: Amersham model 6733, Draximage model LS‐1, Implant Sciences model 3500, IBt model 1251L, IsoAid model IAI‐125A, Mentor model SL‐125/SH‐125, and SourceTech Medical model STM1251. The Best Medical model 2335 source is also included. While the methodology used to determine these data sets is identical to that published in the AAPM TG‐43U1 report, additional information and discussion are presented here on some questions that arose since the publication of the TG‐43U1 report. Specifically, details of interpolation and extrapolation methods are described further, new methodologies are recommended, and example calculations are provided. Despite these changes, additions, and clarifications, the overall methodology, the procedures for developing consensus data sets, and the dose calculation formalism largely remain the same as in the TG‐43U1 report. Thus, the AAPM recommends that the consensus data sets and resultant source‐specific dose‐rate distributions included in this supplement be adopted by all end users for clinical treatment planning of low‐energy photon‐emitting brachytherapy sources. Adoption of these recommendations may result in changes to patient dose calculations, and these changes should be carefully evaluated and reviewed with the radiation oncologist prior to implementation of the current protocol.

Từ khóa


Tài liệu tham khảo

10.1118/1.597458

10.1118/1.1646040

10.1118/1.1812603

10.1118/1.1884925

10.1118/1.1905823

10.1118/1.1905824

10.1118/1.598456

10.1118/1.1645681

Radiological Physics Center The M.D. Anderson Cancer Center Houston Texashttp://rpc.mdanderson.org/rpc/last accessed May 11 2007.

10.1118/1.598764

10.1118/1.1781552

10.1118/1.1759826

10.1118/1.2199987

10.1118/1.598497

10.1016/S1538-4721(02)00102-2

10.1118/1.1470210

J. H.HubbellandS. M.Seltzer “Tables of x‐ray mass attenuation coefficients and mass energy‐absorption coefficientsfor elementsto 92 and 48 additional substances of dosimetric interest ” NISTIR 5632 (1995).

10.1118/1.596631

10.1016/S0969-8043(01)00128-2

10.1118/1.596182

10.1118/1.1445411

10.1118/1.1452733

10.1016/S0969-8043(02)00051-9

10.1118/1.1690712

J. F.Williamson personal communication December2004.

10.1118/1.1357456

10.1016/S0969-8043(01)00254-8

10.1016/S0969-8043(02)00110-0

10.1016/j.apradiso.2004.05.070

10.1118/1.1415072

10.1088/0031-9155/49/8/014

10.1016/S0969-8043(01)00258-5

B.Reniers private communication May 26 2006.

10.1118/1.1500395

10.1118/1.1538615

10.1120/jacmp.v3i2.2576

10.1118/1.596630

10.1118/1.596069

M. J.BergerandJ. J.Hubbell “XCOM: Photon cross sections on a personal computer ” National Bureau of Standards Internal Report No. 87 3597(1987).

10.2307/3578607

10.1118/1.1398563

10.1118/1.1496099

10.1118/1.1496100

10.1118/1.1323980

10.1118/1.1478559

10.1118/1.596322

10.1118/1.1367280

10.1118/1.1446107

10.1120/jacmp.v3i3.2564

10.1118/1.1577251

10.1118/1.1460876

10.1118/1.1388218

10.1016/S1538-4721(02)00015-6

10.1118/1.1414007

J. F.Williamson personal communication December2001.

10.1118/1.2357018

10.1016/S1538-4721(03)00008-4