Statistical Modeling of Lower Limb Kinetics During Deep Squat and Forward Lunge

Joris De Roeck1, Jan Van Houcke1, D. Almeida2, Pavel E. Galibarov3, Lynn De Roeck1, Emmanuel Audenaert4,1,5,6
1Department of Human Structure and Repair, Ghent University, Belgium
2Centre for Rapid and Sustainable Product Development, Polytechnic Institute of Leiria, Portugal
3AnyBody Technology A/S, Denmark
4Department of Electromechanics, Op3Mech Research Group, University of Antwerp, Belgium
5Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, Belgium
6Department of Trauma and Orthopaedics, Addenbrooke’s Hospital, Cambridge University Hospitals NHS Foundation Trust, United Kingdom

Tóm tắt

Từ khóa


Tài liệu tham khảo

Almeida, 2016, Fully automatic segmentation of femurs with medullary canal definition in high and in low resolution CT scans., Med. Eng. Phys., 38, 1474, 10.1016/j.medengphy.2016.09.019

Audenaert, 2019, Statistical shape modelling of skeletal anatomy for sex discrimination: their training size, sexual dimorphism and asymmetry., Front. Bioeng. Biotechnol., 7, 10.3389/fbioe.2019.00302

Audenaert, 2012, Hip morphological characteristics and range of internal rotation in femoroacetabular impingement., Am. J. Sports Med., 40, 1329, 10.1177/0363546512441328

Bagwell, 2016, Hip kinematics and kinetics in persons with and without cam femoroacetabular impingement during a deep squat task., Clin. Biomech., 31, 87, 10.1016/j.clinbiomech.2015.09.016

Benedetti, 2003, Muscle activation pattern and gait biomechanics after total knee replacement., Clin. Biomech., 18, 871, 10.1016/s0268-0033(03)00146-3

Bischoff, 2014, Incorporating population-level variability in orthopedic biomechanical analysis: a review., J. Biomech. Eng., 136, 10.1115/1.4026258

Cappozzo, 1996, Position and orientation in space of bones during movement: experimental artefacts., Clin. Biomech., 11, 90, 10.1016/0268-0033(95)00046-1

Carbone, 2015, TLEM 2.0 – A comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity., J. Biomech., 48, 734, 10.1016/j.jbiomech.2014.12.034

Carbone, 2012, Sensitivity of subject-specific models to errors in musculo-skeletal geometry., J. Biomech., 45, 2476, 10.1016/j.jbiomech.2012.06.026

Daffertshofer, 2004, PCA in studying coordination and variability: a tutorial., Clin. Biomech., 19, 415, 10.1016/j.clinbiomech.2004.01.005

Damsgaard, 2006, Analysis of musculoskeletal systems in the anybody modeling system., Simul. Model. Pract. Theory, 14, 1100, 10.1016/j.simpat.2006.09.001

de Ruiter, 2017, The mechanical response of a polyetheretherketone femoral knee implant under a deep squatting loading condition., Proc. Instit. Mech. Eng. H J. Eng. Med., 231, 1204, 10.1177/0954411917738805

Deluzio, 2007, Biomechanical features of gait waveform data associated with knee osteoarthritis: an application of principal component analysis., Gait Posture, 25, 86, 10.1016/j.gaitpost.2006.01.007

Galloway, 2012, Development of a statistical model of knee kinetics for applications in pre-clinical testing., J. Biomech., 45, 191, 10.1016/j.jbiomech.2011.09.009

Ghaffari, 2018, Current concepts of femoroacetabular impingement., Radiol. Clin. North Am., 56, 965, 10.1016/j.rcl.2018.06.009

Hartmann, 2013, Analysis of the load on the knee joint and vertebral column with changes in squatting depth and weight load., Sports Med., 43, 993, 10.1007/s40279-013-0073-6

Henak, 2013, Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning., J. Biomech. Eng., 135, 10.1115/1.4023386

Honari, 2013, Commentary on Crawford, et al., The role of patch testing in the evaluation of orthopedic implant-related adverse effects: current evidence does not support broad use., Dermatitis, 24, 108, 10.1097/der.0b013e3182979722

Jackson, 2005, A user’s Guide to Principal Components.

Jolliffe, 2002, Principal Component Analysis

Jolliffe, 2016, Principal component analysis: a review and recent developments., Philos. Trans. R. Soc. A Math. Phys. Eng. Sci., 374, 10.1098/rsta.2015.0202

Kang, 2008, Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE., J. Biomech., 41, 340, 10.1016/j.jbiomech.2007.09.005

Knoop, 2012, Biomechanical factors and physical examination findings in osteoarthritis of the knee: associations with tissue abnormalities assessed by conventional radiography and high-resolution 3.0 Tesla magnetic resonance imaging., Arthritis Res. Ther., 14, 10.1186/ar4050

Kutzner, 2010, Loading of the knee joint during activities of daily living measured in vivo in five subjects., J. Biomech., 43, 2164, 10.1016/j.jbiomech.2010.03.046

Lai, 2009, Computational intelligence in gait research: a perspective on current applications and future challenges., IEEE Trans. Inf. Technol. Biomed., 13, 687, 10.1109/TITB.2009.2022913

Mei, 2017, A biomechanical investigation of right-forward lunging step among badminton players., J. Sports Sci., 35, 457, 10.1080/02640414.2016.1172723

O’Brien, 2015, In-vitro and in-silico investigations on the influence of contact pressure on cross-linked polyethylene wear in total knee replacements., Wear, 332, 687, 10.1016/j.wear.2015.02.048

Paulsen, 2011, Sobotta Atlas of Human Anatomy

Peres-Neto, 2005, How many principal components? Stopping rules for determining the number of non-trivial axes revisited., Comput. Stat. Data Anal., 49, 974, 10.1016/j.csda.2004.06.015

Pietsch, 2013, Patient-specific total knee arthroplasty: the importance of planning by the surgeon., Knee Surg. Sports Traumatol. Arthrosc., 21, 2220, 10.1007/s00167-013-2624-7

Reid, 2010, Differentiation of young and older adult stair climbing gait using principal component analysis., Gait Posture, 31, 197, 10.1016/j.gaitpost.2009.10.005

Robbins, 2013, Reliability of principal components and discrete parameters of knee angle and moment gait waveforms in individuals with moderate knee osteoarthritis., Gait Posture, 38, 421, 10.1016/j.gaitpost.2013.01.001

Saliba, 2018, Prediction of knee joint contact forces from external measures using principal component prediction and reconstruction., J. Appl. Biomech., 34, 419, 10.1123/jab.2017-0262

Schwab, 2006, Gravity line analysis in adult volunteers: age-related correlation with spinal parameters, pelvic parameters, and foot position., Spine, 31, E959, 10.1097/01.brs.0000248126.96737.0f

Shu, 2018, A subject-specific finite element musculoskeletal framework for mechanics analysis of a total knee replacement., J. Biomech., 77, 146, 10.1016/j.jbiomech.2018.07.008

Smoger, 2016, Statistical Modeling to Investigate Anatomy and Function of the Knee.

Spencer-Gardner, 2016, Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty., Bone Joint J., 98, 1342, 10.1302/0301-620x.98b10.37808

Styner, 2003, Evaluation of 3D correspondence methods for model building., Inf. Process. Med. Imaging, 18, 63, 10.1007/978-3-540-45087-0_6

Taylor, 2012, Influence of loading and activity on the primary stability of cementless tibial trays., J. Orthopaedic Res., 30, 1362, 10.1002/jor.22056

Vaitkus, 2015, A general framework for constrained mesh parameterization, Proceedings of the 31st Spring Conference on Computer Graphics, 10.1145/2788539.2788541

Vasco, 2012, Permutation tests to estimate significances on Principal Components Analysis., Comput. Ecol. Softw., 2

Wang, 2017, Automatic construction of statistical shape models using deformable simplex meshes with vector field convolution energy., Biomed. Eng. Online, 16, 10.1186/s12938-017-0340-0

Waxman, 2004, WHO Global Strategy on Diet, Physical Activity and Health.

Worsley, 2011, Predicted knee kinematics and kinetics during functional activities using motion capture and musculoskeletal modelling in healthy older people., Gait Posture, 33, 268, 10.1016/j.gaitpost.2010.11.018

Zhang, 2016, Lower limb estimation from sparse landmarks using an articulated shape model., J. Biomech., 49, 3875, 10.1016/j.jbiomech.2016.10.021