State of the Art of Short Dental Implants: A Systematic Review of the Literature

Clinical Implant Dentistry and Related Research - Tập 14 Số 4 - Trang 622-632 - 2012
Camilla Albeck Neldam1, Else Marie Pinholt2
1Scholarship student, Department of Oral and Maxillofacial Surgery, Institute of Odontology, University of Copenhagen, Copenhagen, Denmark.
2professor, Department of Oral and Maxillofacial Surgery, Institute of Odontology, University of Copenhagen, Copenhagen, Denmark

Tóm tắt

ABSTRACT

Background: Short implants (≤8 mm) are manufactured for use in atrophic regions of the jaws. As implant length in many studies has been proven to play a major role in implant survival it is indicated to evaluate survival of short implants in the present literature.

Purpose: The purpose of this study was systematically to evaluate publications concerning short dental implants defined as an implant with a length of ≤8 mm installed in the maxilla or in the mandible with special reference to implant type, survival rate, location of implant site, and observation time.

Materials and Methods: A Medline and a hand search were conducted to identify studies concerning short dental implants of length ≤8 mm published between 1992 and October 2009. The articles included in this study report data on implant length ≤8 mm, implant surface, registered region of installment, observation time, single tooth restorations, supporting overdentures, splinted implants, and implants used for prostheses.

Results: The 27 included studies represent zero randomized clinical trial studies, 15 prospective nonrandomized, noncontrolled clinical trials, 11 retrospective nonrandomized, noncontrolled clinical trials, and one review. Data on 6‐mm implants were few and most frequent represented was manufactured Straumann implants representing 441 out of 549 implants. Brånemark implants, 7 mm in length, comprised 1607 implants out of 1808. Straumann implants, 8 mm in length, comprised 2040 out of 2352 implants. Failures varied between 0 and 14.5%, 0 and 37.5% and 0 and 22.9% of the 6‐, 7‐, and 8‐mm‐long implants, respectively.

Conclusion: Short implant length was not related to observation time, installment region, failures, and dropouts were not specified, subsequently a meta‐analysis was not possible to perform.

Từ khóa


Tài liệu tham khảo

10.1111/j.1600-0501.2006.01349.x

Ferrigno N, 2005, Inferior alveolar nerve transposition in conjunction with implant placement, Int J Oral Maxillofac Implants, 20, 610

Deporter D, 2000, Simplifying management of the posterior maxilla using short, porous‐surfaced dental implants and simultaneous indirect sinus elevation, Int J Periodontics Restorative Dent, 20, 476

Bahat O, 2000, Branemark system implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years, Int J Oral Maxillofac Implants, 15, 646

10.1111/j.1708-8208.2005.tb00082.x

10.1111/j.1708-8208.2004.tb00023.x

10.1111/j.1708-8208.2000.tb00116.x

Fugazzotto PA, 2008, Shorter implants in clinical practice: rationale and treatment results, Int J Oral Maxillofac Implants, 23, 487

10.1902/jop.1999.70.12.1523

Ekfeldt A, 1994, Clinical evaluation of single‐tooth restorations supported by osseointegrated implants: a retrospective study, Int J Oral Maxillofac Implants, 9, 179

Lekholm U, 1994, Osseointegrated implants in the treatment of partially edentulous jaws: a prospective 5‐year multicenter study, Int J Oral Maxillofac Implants, 9, 627

10.1034/j.1600-0501.2002.130406.x

Bahat O, 1996, Use of wide implants and double implants in the posterior jaw: a clinical report, Int J Oral Maxillofac Implants, 11, 379

Lekholm U, 1985, Tissueintegrated Prostheses: Osseointegration in Clinical Dentistry, 199

10.1902/jop.1999.70.8.896

Jemt T, 1992, Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup, Int J Oral Maxillofac Implants, 7, 40

Jemt T, 1993, Oral implant treatment in posterior partially edentulous jaws: a 5‐year follow‐up report, Int J Oral Maxillofac Implants, 8, 635

10.1034/j.1600-0501.1994.050304.x

10.1016/0022-3913(92)90461-I

10.1111/j.1600-0501.2004.00978.x

10.1016/S0022-3913(97)70121-5

Friberg B, 1991, Early failures in 4,641 consecutively placed Branemark dental implants: a study from stage 1 surgery to the connection of completed prostheses, Int J Oral Maxillofac Implants, 6, 142

10.1111/j.1708-8208.2003.tb00208.x

Rangert B, 1995, Bending overload and implant fracture: a retrospective clinical analysis, Int J Oral Maxillofac Implants, 10, 326

10.1046/j.1365-2842.2002.00872.x

10.1034/j.1600-0501.2001.120604.x

10.1111/j.1600-0501.2007.01454.x

10.1902/jop.2004.75.6.798

10.1002/j.0022-0337.2003.67.8.tb03681.x

10.1111/j.1600-0501.2006.01306.x

10.1902/jop.2008.070142

10.1111/j.1600-0501.2004.01017.x

Brocard D, 2000, A multicenter report on 1022 consecutively placed ITI implants: a 7‐year longitudinal study, Int J Oral Maxillofac Implants, 15, 691

10.1034/j.1600-0501.1997.080302.x

das Neves FD, 2006, Short implants‐an analysis of longitudinal studies, Int J Oral Maxillofac Implants, 21, 86

10.1034/j.1600-0501.1999.100208.x

Degidi M, 2007, Immediately loaded short implants: analysis of a case series of 133 implants, Quintessence Int, 38, 193

Deporter D, 2001, Managing the posterior mandible of partially edentulous patients with short, porous‐surfaced dental implants: early data from aclinical trial, Int J Oral Maxillofac Implants, 16, 653

10.1034/j.1600-0501.2002.130305.x

Gentile MA, 2005, Survival estimates and risk factors for failure with 6 x 5.7‐mm implants, Int J Oral Maxillofac Implants, 20, 930

10.1097/01.id.0000173335.90854.d8

10.1016/j.joms.2008.11.004

Herrmann I, 2005, Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures, Int J Oral Maxillofac Implants, 20, 220

10.1902/jop.2006.050402

10.1034/j.1600-0501.2002.130407.x

Pylant T, 1992, A retrospective evaluation of endosseous titanium implants in the partially edentulous patient, Int J Oral Maxillofac Implants, 7, 195

10.1034/j.1600-0501.2002.130203.x

Romeo E, 2004, Long‐term survival and success of oral implants in the treatment of full and partial arches: a 7‐year prospective study with the ITI dental implant system, Int J Oral Maxillofac Implants, 19, 247

Scurria MS, 1998, Prognostic variables associated with implant failure: a retrospective effectiveness study, Int J Oral Maxillofac Implants, 13, 400

10.1097/01.ID.0000091140.76130.A1

Testori T, 2001, A prospective multicenter clinical study of the Osseotite implant: four‐year interim report, Int J Oral Maxillofac Implants, 16, 193

10.1034/j.1600-0501.2002.130205.x

Triplett RG, 1991, Endosseous cylinder implants in severely atrophic mandibles, Int J Oral Maxillofac Implants, 6, 264

10.1034/j.1600-0501.2000.011003202.x

Weng D, 2003, A prospective multicenter clinical trial of 3i machined‐surface implants: results after 6 years of follow‐up, Int J Oral Maxillofac Implants, 18, 417

10.1902/annals.2000.5.1.22

Wyatt CC, 1998, Treatment outcomes of patients with implant‐supported fixed partial prostheses, Int J Oral Maxillofac Implants, 13, 204

10.1111/j.1600-0501.2006.01271.x

ten Bruggenkate CM, 1998, Short (6‐mm) nonsubmerged dental implants: results of a Multicenter clinical trial of 1 to 7 years, Int J Oral Maxillofac Implants, 13, 791

Ivanoff CJ, 1999, Influence of variations in implant diameters: a 3‐ to 5‐year retrospective clinical report, Int J Oral Maxillofac Implants, 14, 173

10.1034/j.1600-0501.1995.060405.x

10.1016/0278-2391(95)90222-8

10.1034/j.1600-0501.1993.040404.x

Jemt T, 1995, Implant treatment in edentulous maxillae: a 5‐year follow‐up report on patients with different degrees of jaw resorption, Int J Oral Maxillofac Implants, 10, 303

Lekholm U, 1999, Survival of the Branemark implant in partially edentulous jaws: a 10‐year prospective multicenter study, Int J Oral Maxillofac Implants, 14, 639

Nevins M, 1993, The successful application of osseointegrated implants to the posterior jaw: a long‐term retrospective study, Int J Oral Maxillofac Implants, 8, 428

10.1034/j.1600-0501.1992.030302.x

10.1902/jop.2004.75.2.327

Tawil G, 2003, Clinical evaluation of short, machined‐surface implants followed for 12 to 92 months, Int J Oral Maxillofac Implants, 18, 894

10.1034/j.1600-0501.1997.080304.x

Block MS, 1996, Hydroxyapatite‐coated cylindrical implants in the posterior mandible: 10‐year observations, Int J Oral Maxillofac Implants, 11, 626

10.1016/j.prosdent.2004.05.010

Albrektsson T, 1986, Osseointegrated dental implants, Dent Clin North Am, 30, 151, 10.1016/S0011-8532(22)02100-0

10.1111/j.1600-051X.1992.tb00450.x

Deporter DA, 2001, A prospective human clinical trial of Endopore dental implants in restoring the partially edentulous maxilla using fixed prostheses, Int J Oral Maxillofac Implants, 16, 527

Roos‐Jansaker AMA, 2007, Long time follow‐up of imlpant therapy and treatment of peri‐implantitis, Swed Dent J, 7