Squeaking in Ceramic-on-Ceramic Hips

Journal of Arthroplasty - Tập 22 Số 4 - Trang 496-503 - 2007
William L. Walter1, Gary O’Toole1, Andrew Ellis2, B. Zicat1
1Sydney Hip and Knee Surgeons, Sydney, NSW, Australia
2Royal North Shore Hospital, Pacific Highway St Leonards, NSW, Australia

Tóm tắt

Từ khóa


Tài liệu tham khảo

Boutin, 1972, Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications, Rev Chir Orthop Reparatrice Appar Mot, 58, 3

Oonishi, 2004, Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model, J Biomed Mater Res A, 70, 4

Nevelos, 2001, Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions, Biomaterials, 22, 16, 10.1016/S0142-9612(00)00361-6

Hamadouche, 2002, Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study, J Bone Joint Surg Am, 84-A, 1

Kavanagh, 1994, Charnley low-friction arthroplasty of the hip. Twenty-year results with cement, J Arthroplasty, 9, 3, 10.1016/0883-5403(94)90076-0

Amstutz, 1991, Evolution of hip arthroplasty, 1

Charnley, 1979

Morlock, 2001, Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty, J Arthroplasty, 16, 8, 10.1054/arth.2001.27233

Back, 2005, Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips, J Bone Joint Surg Br, 87, 3

Ackland, 1986, Anteversion of the acetabular cup. Measurement of angle after total hip replacement, J Bone Joint Surg Br, 68, 3

Murray, 1993, The definition and measurement of acetabular orientation, J Bone Joint Surg Br, 75, 2

Walter, 2004, Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear, J Arthroplasty, 19, 4, 10.1016/j.arth.2003.09.018

Armitage, 2002

Digioia, 2005

McCollum, 1990, Dislocation after total hip arthroplasty. Causes and prevention, Clin Orthop, 261

Digioia, 2002, Comparison of a mechanical acetabular alignment guide with computer placement of the socket, J Arthroplasty, 17, 3, 10.1054/arth.2002.30411

Kennedy, 1998, Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration, J Arthroplasty, 13, 5, 10.1016/S0883-5403(98)90052-3

Schmalzried, 1994, The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis, J Bone Joint Surg Am, 76, 5, 10.2106/00004623-199405000-00008

Patil, 2003, Polyethylene wear and acetabular component orientation, J Bone Joint Surg Am, 85-A, 56, 10.2106/00004623-200300004-00007

Lewinnek, 1978, Dislocations after total hip-replacement arthroplasties, J Bone Joint Surg Am, 60, 2, 10.2106/00004623-197860020-00014