Split dose carbon ion irradiation of the rat spinal cord: Dependence of the relative biological effectiveness on dose and linear energy transfer

Radiotherapy and Oncology - Tập 117 - Trang 358-363 - 2015
Maria Saager1,2, Christin Glowa1,2, Peter Peschke3, Stephan Brons4, Rebecca Grün5, Michael Scholz5, Peter E. Huber1,3, Jürgen Debus1, Christian P. Karger2
1Dept. of Radiation Oncology, University Hospital of Heidelberg, Germany
2Dept. of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
3Clinical Cooperation Unit Molecular Radiooncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
4Heidelberg Ion Beam Therapy Center (HIT), Heidelberg, Germany
5Dept. of Biophysics, Helmholtz Center for Heavy Ion Research (GSI), Darmstadt, Germany

Tài liệu tham khảo

Karger, 2006, Radiation tolerance of the rat spinal cord after 6 and 18 fractions of photons and carbon ions: experimental results and clinical implications, Int J Radiat Oncol Biol Phys, 66, 1488, 10.1016/j.ijrobp.2006.08.045 Debus, 2003, Radiation tolerance of the rat spinal cord after single and split doses of photons and carbon ions, Radiat Res, 160, 536, 10.1667/3063 Suit, 2010, Proton vs carbon ion beams in the definitive radiation treatment of cancer patients, Radiother Oncol, 95, 3, 10.1016/j.radonc.2010.01.015 Schulz-Ertner, 2007, Particle radiation therapy using proton and heavier ion beams, J Clin Oncol, 25, 953, 10.1200/JCO.2006.09.7816 Tsujii, 2012, A review of update clinical results of carbon ion radiotherapy, Jpn J Clin Oncol, 42, 670, 10.1093/jjco/hys104 Scholz, 1997, Computation of cell survival in heavy ion beams for therapy. The model and its approximation, Radiat Environ Biophys, 36, 59, 10.1007/s004110050055 Elsasser, 2010, Quantification of the relative biological effectiveness for ion beam radiotherapy: direct experimental comparison of proton and carbon ion beams and a novel approach for treatment planning, Int J Radiat Oncol Biol Phys, 78, 1177, 10.1016/j.ijrobp.2010.05.014 Kanai, 1997, Irradiation of mixed beam and design of spread-out Bragg peak for heavy-ion radiotherapy, Radiat Res, 147, 78, 10.2307/3579446 van der Kogel, 1974, Late effects of spinal cord irradiation with 300kV X rays and 15MeV neutrons, Br J Radiol, 47, 393, 10.1259/0007-1285-47-559-393 Okada, 1998, Histopathological and morphometric study of the late effects of heavy-ion irradiation on the spinal cord of the rat, Radiat Res, 150, 304, 10.2307/3579980 Leith, 1982, Response of rat spinal cord to single and fractionated doses of accelerated heavy ions, Radiat Res, 89, 176, 10.2307/3575694 Saager, 2014, Carbon ion irradiation of the rat spinal cord: dependence of the relative biological effectiveness on linear energy transfer, Int J Radiat Oncol Biol Phys, 90, 63, 10.1016/j.ijrobp.2014.05.008 Jakel, 2001, Treatment planning for heavy ion radiotherapy: clinical implementation and application, Phys Med Biol, 46, 1101, 10.1088/0031-9155/46/4/314 Haberer, 1993, Magnetic scanning system for heavy ion therapy, Nucl Instrum Methods Phys Res, Sect A, 330, 296, 10.1016/0168-9002(93)91335-K Walker, 1983, Assessment of local tumor control using censored tumor response data, Int J Radiat Oncol Biol Phys, 9, 383, 10.1016/0360-3016(83)90300-0 StatSoft I, STATISTICA für Windows [Software-System für Datenanalyse]. Version 6. http://www.statsoft.com, 2004. Finney, 1978 Bijl, 2002, Dose-volume effects in the rat cervical spinal cord after proton irradiation, Int J Radiat Oncol Biol Phys, 52, 205, 10.1016/S0360-3016(01)02687-6 Bijl, 2005, Regional differences in radiosensitivity across the rat cervical spinal cord, Int J Radiat Oncol Biol Phys, 61, 543, 10.1016/j.ijrobp.2004.10.018 Bijl, 2003, Unexpected changes of rat cervical spinal cord tolerance caused by inhomogeneous dose distributions, Int J Radiat Oncol Biol Phys, 57, 274, 10.1016/S0360-3016(03)00529-7 Hopewell, 1987, The influence of field size on the late tolerance of the rat spinal cord to single doses of X rays, Br J Radiol, 60, 1099, 10.1259/0007-1285-60-719-1099 Laissue, 2013, Response of the rat spinal cord to X-ray microbeams, Radiother Oncol, 106, 106, 10.1016/j.radonc.2012.12.007 Philippens, 2009, Bath and shower effect in spinal cord: the effect of time interval, Int J Radiat Oncol Biol Phys, 73, 514, 10.1016/j.ijrobp.2008.09.028 Ruifrok, 1994, Radiation response of the rat cervical spinal cord after irradiation at different ages: tolerance, latency and pathology, Int J Radiat Oncol Biol Phys, 29, 73, 10.1016/0360-3016(94)90228-3 Geyer, 1991, The effect of age on the latency of radiation myelopathy, J Neurooncol, 10, 145, 10.1007/BF00146876 Okada, 2001, Pathology of radiation myelopathy, Neuropathology, 21, 247, 10.1046/j.1440-1789.2001.00408.x Weyrather, 1999, RBE for carbon track-segment irradiation in cell lines of differing repair capacity, Int J Radiat Biol, 75, 1357, 10.1080/095530099139232 Georgakilas, 2013, Induction and repair of clustered DNA lesions: what do we know so far?, Radiat Res, 180, 100, 10.1667/RR3041.1 Schultheiss, 1992, Neutron RBE for primate spinal cord treated with clinical regimens, Radiat Res, 129, 212, 10.2307/3578159 Scholz, 2006, Test of the local effect model using clinical data: tumour control probability for lung tumours after treatment with carbon ion beams, Radiat Prot Dosimetry, 122, 478, 10.1093/rpd/ncl426