Single- versus double-row repair for full-thickness rotator cuff tears using suture anchors. A systematic review and meta-analysis of basic biomechanical studies
Tóm tắt
Từ khóa
Tài liệu tham khảo
Roth KM, Warth R, Lee JT, Millett PJ, ElAttrache NS (2014) Arthroscopic single-row versus double-row repair for full-thickness posterosuperior rotator cuff tears. JBJS Rev 2(7):e6. https://doi.org/10.2106/JBJS.RVW.M.00081
Lee TQ (2013) Current biomechanical concepts for rotator cuff repair. Clin Orthop Surg 5:89–97. https://doi.org/10.4055/cios.2013.5.2.89
Park MC, Cadet ER, Levine WN, Bigliani LU, Ahmad CS (2005) Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques. Am J Sports Med 33(8):1154–1159. https://doi.org/10.1177/0363546504273053
Ahmad CS, Stewart AM, Izquierdo R, Bigliani LU (2005) Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques. Am J Sports Med 33(11):1667–1671. https://doi.org/10.1177/0363546505278252
Park JS, McGarry MH, Campbell ST, Seo HJ, Lee YS, Kim SH et al (2015) The optimum tension for briging sutures in transosseous-equivalent rotator cuff repair: a cadaveric biomechanical study. Am J Sports Med 43(9):2118–2125. https://doi.org/10.1177/0363546515590596
Ahmad CS, Kleweno C, Jacir AM, Bell JE, Gardner TR, Levine WN et al (2008) Biomechanical performance of rotator cuff repairs with humeral rotation: a new rotator cuff repair failure model. Am J Sports Med 36:888–892. https://doi.org/10.1177/0363546508316285
Esquivel AO, Duncan DD, Dobrasevic N, Marsh SM, Lemos SE (2015) Load to failure and stiffness. Anchor placement and suture pattern effects on load to failure in rotator cuff repairs. Orthop J Sports Med 7(3):2325967115579052. https://doi.org/10.1177/2325967115579052
Ma CB, Comerford L, Wilson J, Puttlitz CM (2006) Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation. J Bone Jt Surg Am 88:403–410. https://doi.org/10.2106/JBJS.D.02887
Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Jt Surg Am 86A:219–224
Mazzocca AD, Millett PJ, Guanche CA, Santangelo SA, Arciero RA (2005) Arthroscopic single-row versus double-row suture anchor rotator cuff repair. Am J Sports Med 33(12):1861–1868. https://doi.org/10.1177/0363546505279575
Smith CD, Alexander S, Hill AM, Huijsmans PE, Bull AMJ, Amis AA et al (2006) A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair. J Bone Jt Surg 88A(11):2425–2431. https://doi.org/10.2106/JBJS.E.00697
Mascarenhas R, Chalmers PN, Sayegh ET, Bhandari M, Verma NN, Cole B et al (2014) Is double-row rotator cuff repair clinically superior to single-row rotator cuff repair: a systematic review of overlapping meta-analyses. Arthroscopy 30(9):1156–1165. https://doi.org/10.1016/j.arthro.2014.03.015
Burks RT, Crim J, BrownN Fink B, Greis PE (2009) A prospective randomized clinical trial comparing arthroscopic single- and double row rotator cuff repair: magnetic resonance imaging and early clinical evaluation. Am J Sports Med 37(4):674–682. https://doi.org/10.1177/0363546508328115
Higgins JPT, Green S (2011) Cochrane handbook for systematic reviews of interventions. Version 5.1.9 [updated March 2011]. The Cochrane Collaboration
Moher D, Liberati A, Tetzlaff J, Altman DG (2010) Preferred reporting items for systematic reviews and meta-analysis: the PRISMA statement. Int J Surg 8:336–341. https://doi.org/10.1016/j.ijsu.2010.02.007
Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ (2007) Part I: footprint contact characteristics for transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16(4):461–468. https://doi.org/10.1016/j.jse.2006.09.010
Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ (2007) Part II: biomechanical assessment for a footprint restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16(4):469–476. https://doi.org/10.1016/j.jse.2006.09.011
Pietschmann MF, Hölzer A, Rösl C, Scharpf A, Niethammer T, Jansson V et al (2010) What humeri are suitable for comparative testing of suture anchors? An ultrastructural bone analysis and biomechanical study of ovine, bovine and human humeri and four different anchor types. J Biomech 43(6):1125–1130. https://doi.org/10.1016/j.jbiomech.2009.12.021
Hartling L, Hamm M, Milne A, Vandermeer B, Santaguida PL, Ansari M et al (2012) Validity and inter-rater reliability testing of quality assessment instruments. (Prepared by the University of Alberta Evidence-based Practice Center under Contract No. 290-2007-10021-I.) AHRQ Publication No. 12-EHC039-EF. Rockville, MD: Agency for Healthcare Research and Quality. March 2012. www.effectivehealthcare.ahrq.gov/reports/final.cfm . Accessed 12 Aug 2016
Hozo SP, Djulbegovic B, Hozo I (2005) Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 5:13. https://doi.org/10.1186/1471-2288-5-13
Barber FA, Drew OR (2012) A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple loaded cuff repairs and double-row, suture tape cuff repairs using biocomposite anchors. Arthroscopy 28(9):1197–1205. https://doi.org/10.1016/j.arthro.2012.02.015
Domb BG, Glousman RE, Brooks A, Hansen M, Lee TQ, ElAttrache NS (2008) High-tension double-row footprint repair compared with reduced tension single-row repair for massive rotator cuff tears. J Bone Jt Surg 90(Suppl 4):35–39. https://doi.org/10.2106/jbjs.h.00650
Kim DH, ElAtrrache NS, Tibone JE, Jun BJ, DeLaMora SN, Kitne RS et al (2006) Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am Sports Med 34(3):407–414. https://doi.org/10.1177/0363546505281238
Lorbach O, Kieb M, Raber F, Busch LC, Kohn D, Pape D (2012) Comparable biomechanical results for a modified single-row rotator cuff reconstruction using triple loaded suture anchors versus a suture-bridging double-row repair. Arthroscopy 28(2):178–187. https://doi.org/10.1016/j.arthro.2011.08.298
Millett PJ, Warth RJ, Dornan GJ, Lee JT, Spiegl UJ (2014) Clinical and structural outcomes after arthroscopic single-row versus double-row rotator cuff repair: a systematic review and meta-analysis of level I randomized clinical trials. J Shoulder Elbow Surg 23(4):586–597. https://doi.org/10.1016/j.jse.2013.10.006
Zhang Q, Ge H, Zhou Yuan C, Chen K, Cheng B (2013) Single-row or double-row fixation techniques for full thickness rotator cuff tears: a meta-analysis. PLoS ONE 8(7):e68515. https://doi.org/10.1371/journal.pone.0068515
Jost PW, Khair MM, Chen DX, Wright TM, Kelly AM, Rodeo SA (2012) Suture number determines strength of rotator cuff repair. J Bone Jt Surg Am 94(14):e100. https://doi.org/10.2106/JBJS.K.00117
Goschka AM, Hafer JS, Reynolds KA, Aberle NS II, Baldini TH, Hawkins MJ et al (2015) Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model. Clin Biomech 30:808–813. https://doi.org/10.1016/j.clinbiomech.2015.06.009
Burkhart SS, Diaz Pagan JL, Wirth MA, Athanasiou KA (1997) Cyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. Arthroscopy 13(6):720–724
Nelson CO, Sileo MJ, Grossman MG, Serra-Hsu F (2008) Single-row modified mason-allen versus double-row arthroscopic rotator cuff repair: a biomechanical and surface area comparison. Arthroscopy 24(8):941–948. https://doi.org/10.1016/j.arthro.2008.03.011
Abtahi AM, Granger EK, Tashjian RZ (2015) Factors affecting healing after arthroscopic rotator cuff repair. World J Orthop 6(2):211–220. https://doi.org/10.5312/wjo.v6.i2.211
Perser K, Godfrey D, Bisson L (2011) Meta-analysis of clinical and radiographic outcomes after arthroscopic single-row versus double-row rotator cuff repair. Sports Health 3(3):268–274
Sheibani-Rad S, Giveans MR, Arnoczky SP, Bedi A (2013) Arthroscopic single-row versus double-row repair: a meta-analysis of the randomized clinical trials. Arthroscopy 29(2):343–348
DeHaan AM, Axelrad TW, Kaye E, Silvestri L, Puskas B, Foster TE (2012) Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review. Am J Sports Med 40(5):1176–1185
Yang J Jr, Robbins M, Reilly J, Maerz T, Anderson K (2017) The clinical effect of rotator cuff repair: a meta-analysis of arthroscopic single-row and double-row repairs. Am J Sports Med 45(3):733–741
Haidich AB (2010) Meta-analysis in medical research. Hippokratia 14(Suppl 1):29–37
Ioannidis JPA, Haidich A-B, Pappa M, Pantazis N, Kokori SI, Tektonidou MG et al (2001) Comparison of evidence of treatment effects in randomized and non-randomized studies. JAMA 286:821–830
Parimi M, Zhao C, Thoreson AR, An KN, Amadio PC (2012) Does velocity affect failure strength after tendon repair? J Biomech 45(16):2939–2942. https://doi.org/10.1016/j.jbiomech.2012.08.039
Ikai M, Fukunaga T (1968) Calculation of muscle strength per unit of cross-sectional area of human muscle. Int Z Angew Physiol einschliesslich Arbeitsphysiol 26:26–31