Single- versus double-row repair for full-thickness rotator cuff tears using suture anchors. A systematic review and meta-analysis of basic biomechanical studies

Springer Science and Business Media LLC - Tập 28 Số 5 - Trang 859-868 - 2018
Erik Hohmann1,2,3, Anya König4, Cor‐Jacques Kat5, Vaida Glatt6, Kevin Tetsworth7,8,9,10, Natalie Keough4
1Clinical Medical School, University of Queensland, St. Lucia, Australia
2Department of Orthopaedic Surgery and Sports Medicine, Valiant Clinic/Houston Methodist Group, Dubai, United Arab Emirates
3Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
4Department of Anatomy, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
5Faculty of Engineering, University of Pretoria, Pretoria, South Africa
6University of Texas Health Science Center, San Antonio, USA
7Department of Orthopaedic Surgery, Royal Brisbane Hospital, Herston, Australia
8Department of Surgery, School of Medicine, University of Queensland, St. Lucia, Australia
9Orthopaedic Research Institute of Australia, Sydney, Australia
10Queensland University of Technology, Brisbane, Australia

Tóm tắt

Từ khóa


Tài liệu tham khảo

Roth KM, Warth R, Lee JT, Millett PJ, ElAttrache NS (2014) Arthroscopic single-row versus double-row repair for full-thickness posterosuperior rotator cuff tears. JBJS Rev 2(7):e6. https://doi.org/10.2106/JBJS.RVW.M.00081

Lee TQ (2013) Current biomechanical concepts for rotator cuff repair. Clin Orthop Surg 5:89–97. https://doi.org/10.4055/cios.2013.5.2.89

Park MC, Cadet ER, Levine WN, Bigliani LU, Ahmad CS (2005) Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques. Am J Sports Med 33(8):1154–1159. https://doi.org/10.1177/0363546504273053

Ahmad CS, Stewart AM, Izquierdo R, Bigliani LU (2005) Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques. Am J Sports Med 33(11):1667–1671. https://doi.org/10.1177/0363546505278252

Park JS, McGarry MH, Campbell ST, Seo HJ, Lee YS, Kim SH et al (2015) The optimum tension for briging sutures in transosseous-equivalent rotator cuff repair: a cadaveric biomechanical study. Am J Sports Med 43(9):2118–2125. https://doi.org/10.1177/0363546515590596

Ahmad CS, Kleweno C, Jacir AM, Bell JE, Gardner TR, Levine WN et al (2008) Biomechanical performance of rotator cuff repairs with humeral rotation: a new rotator cuff repair failure model. Am J Sports Med 36:888–892. https://doi.org/10.1177/0363546508316285

Esquivel AO, Duncan DD, Dobrasevic N, Marsh SM, Lemos SE (2015) Load to failure and stiffness. Anchor placement and suture pattern effects on load to failure in rotator cuff repairs. Orthop J Sports Med 7(3):2325967115579052. https://doi.org/10.1177/2325967115579052

Ma CB, Comerford L, Wilson J, Puttlitz CM (2006) Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation. J Bone Jt Surg Am 88:403–410. https://doi.org/10.2106/JBJS.D.02887

Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K (2004) The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Jt Surg Am 86A:219–224

Mazzocca AD, Millett PJ, Guanche CA, Santangelo SA, Arciero RA (2005) Arthroscopic single-row versus double-row suture anchor rotator cuff repair. Am J Sports Med 33(12):1861–1868. https://doi.org/10.1177/0363546505279575

Smith CD, Alexander S, Hill AM, Huijsmans PE, Bull AMJ, Amis AA et al (2006) A biomechanical comparison of single and double-row fixation in arthroscopic rotator cuff repair. J Bone Jt Surg 88A(11):2425–2431. https://doi.org/10.2106/JBJS.E.00697

Mascarenhas R, Chalmers PN, Sayegh ET, Bhandari M, Verma NN, Cole B et al (2014) Is double-row rotator cuff repair clinically superior to single-row rotator cuff repair: a systematic review of overlapping meta-analyses. Arthroscopy 30(9):1156–1165. https://doi.org/10.1016/j.arthro.2014.03.015

Burks RT, Crim J, BrownN Fink B, Greis PE (2009) A prospective randomized clinical trial comparing arthroscopic single- and double row rotator cuff repair: magnetic resonance imaging and early clinical evaluation. Am J Sports Med 37(4):674–682. https://doi.org/10.1177/0363546508328115

Higgins JPT, Green S (2011) Cochrane handbook for systematic reviews of interventions. Version 5.1.9 [updated March 2011]. The Cochrane Collaboration

Moher D, Liberati A, Tetzlaff J, Altman DG (2010) Preferred reporting items for systematic reviews and meta-analysis: the PRISMA statement. Int J Surg 8:336–341. https://doi.org/10.1016/j.ijsu.2010.02.007

Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ (2007) Part I: footprint contact characteristics for transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16(4):461–468. https://doi.org/10.1016/j.jse.2006.09.010

Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ (2007) Part II: biomechanical assessment for a footprint restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 16(4):469–476. https://doi.org/10.1016/j.jse.2006.09.011

Pietschmann MF, Hölzer A, Rösl C, Scharpf A, Niethammer T, Jansson V et al (2010) What humeri are suitable for comparative testing of suture anchors? An ultrastructural bone analysis and biomechanical study of ovine, bovine and human humeri and four different anchor types. J Biomech 43(6):1125–1130. https://doi.org/10.1016/j.jbiomech.2009.12.021

Hartling L, Hamm M, Milne A, Vandermeer B, Santaguida PL, Ansari M et al (2012) Validity and inter-rater reliability testing of quality assessment instruments. (Prepared by the University of Alberta Evidence-based Practice Center under Contract No. 290-2007-10021-I.) AHRQ Publication No. 12-EHC039-EF. Rockville, MD: Agency for Healthcare Research and Quality. March 2012. www.effectivehealthcare.ahrq.gov/reports/final.cfm . Accessed 12 Aug 2016

Hozo SP, Djulbegovic B, Hozo I (2005) Estimating the mean and variance from the median, range, and the size of a sample. BMC Med Res Methodol 5:13. https://doi.org/10.1186/1471-2288-5-13

Barber FA, Drew OR (2012) A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple loaded cuff repairs and double-row, suture tape cuff repairs using biocomposite anchors. Arthroscopy 28(9):1197–1205. https://doi.org/10.1016/j.arthro.2012.02.015

Domb BG, Glousman RE, Brooks A, Hansen M, Lee TQ, ElAttrache NS (2008) High-tension double-row footprint repair compared with reduced tension single-row repair for massive rotator cuff tears. J Bone Jt Surg 90(Suppl 4):35–39. https://doi.org/10.2106/jbjs.h.00650

Kim DH, ElAtrrache NS, Tibone JE, Jun BJ, DeLaMora SN, Kitne RS et al (2006) Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am Sports Med 34(3):407–414. https://doi.org/10.1177/0363546505281238

Lorbach O, Kieb M, Raber F, Busch LC, Kohn D, Pape D (2012) Comparable biomechanical results for a modified single-row rotator cuff reconstruction using triple loaded suture anchors versus a suture-bridging double-row repair. Arthroscopy 28(2):178–187. https://doi.org/10.1016/j.arthro.2011.08.298

Hughes RE, An KN (1996) Force analysis of rotator cuff muscles. Clin Orthop Relat Res 330:75–83

Millett PJ, Warth RJ, Dornan GJ, Lee JT, Spiegl UJ (2014) Clinical and structural outcomes after arthroscopic single-row versus double-row rotator cuff repair: a systematic review and meta-analysis of level I randomized clinical trials. J Shoulder Elbow Surg 23(4):586–597. https://doi.org/10.1016/j.jse.2013.10.006

Zhang Q, Ge H, Zhou Yuan C, Chen K, Cheng B (2013) Single-row or double-row fixation techniques for full thickness rotator cuff tears: a meta-analysis. PLoS ONE 8(7):e68515. https://doi.org/10.1371/journal.pone.0068515

Jost PW, Khair MM, Chen DX, Wright TM, Kelly AM, Rodeo SA (2012) Suture number determines strength of rotator cuff repair. J Bone Jt Surg Am 94(14):e100. https://doi.org/10.2106/JBJS.K.00117

Goschka AM, Hafer JS, Reynolds KA, Aberle NS II, Baldini TH, Hawkins MJ et al (2015) Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model. Clin Biomech 30:808–813. https://doi.org/10.1016/j.clinbiomech.2015.06.009

Burkhart SS, Diaz Pagan JL, Wirth MA, Athanasiou KA (1997) Cyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. Arthroscopy 13(6):720–724

Nelson CO, Sileo MJ, Grossman MG, Serra-Hsu F (2008) Single-row modified mason-allen versus double-row arthroscopic rotator cuff repair: a biomechanical and surface area comparison. Arthroscopy 24(8):941–948. https://doi.org/10.1016/j.arthro.2008.03.011

Abtahi AM, Granger EK, Tashjian RZ (2015) Factors affecting healing after arthroscopic rotator cuff repair. World J Orthop 6(2):211–220. https://doi.org/10.5312/wjo.v6.i2.211

Perser K, Godfrey D, Bisson L (2011) Meta-analysis of clinical and radiographic outcomes after arthroscopic single-row versus double-row rotator cuff repair. Sports Health 3(3):268–274

Sheibani-Rad S, Giveans MR, Arnoczky SP, Bedi A (2013) Arthroscopic single-row versus double-row repair: a meta-analysis of the randomized clinical trials. Arthroscopy 29(2):343–348

DeHaan AM, Axelrad TW, Kaye E, Silvestri L, Puskas B, Foster TE (2012) Does double-row rotator cuff repair improve functional outcome of patients compared with single-row technique? A systematic review. Am J Sports Med 40(5):1176–1185

Yang J Jr, Robbins M, Reilly J, Maerz T, Anderson K (2017) The clinical effect of rotator cuff repair: a meta-analysis of arthroscopic single-row and double-row repairs. Am J Sports Med 45(3):733–741

Haidich AB (2010) Meta-analysis in medical research. Hippokratia 14(Suppl 1):29–37

Ioannidis JPA, Haidich A-B, Pappa M, Pantazis N, Kokori SI, Tektonidou MG et al (2001) Comparison of evidence of treatment effects in randomized and non-randomized studies. JAMA 286:821–830

Parimi M, Zhao C, Thoreson AR, An KN, Amadio PC (2012) Does velocity affect failure strength after tendon repair? J Biomech 45(16):2939–2942. https://doi.org/10.1016/j.jbiomech.2012.08.039

Ikai M, Fukunaga T (1968) Calculation of muscle strength per unit of cross-sectional area of human muscle. Int Z Angew Physiol einschliesslich Arbeitsphysiol 26:26–31

Thornton A, Lee P (2000) Publication bias in meta-analysis: its causes and consequences. J Clin Epidemiol 53:207–216