Single and simultaneous voltammetric sensing of lead(II), cadmium(II) and zinc(II) using a bimetallic Hg-Bi supported on poly(1,2-diaminoanthraquinone)/glassy carbon modified electrode

Sensing and Bio-Sensing Research - Tập 29 - Trang 100369 - 2020
Khalid Mahmoud Hassan1, Seleem Elsaid Gaber2, Mahmoud Fatehy Altahan2,3, Magdi Abdel Azzem4
1Electrochemistry Research Laboratory, Physics and Mathematics Engineering Department, Faculty of Electronic Engineering, Menoufia University, Menouf 23952, Egypt
2Central Laboratory for Environmental Quality Monitoring, National Water Research Center, El-Qanater El-Khairia 13621, Egypt
3GEOMAR, Helmholtz for Ocean Research, 24148 Kiel, Germany
4Electrochemistry Laboratory, Chemistry Department, Faculty of Science, Menoufia University, Shibin El-Kom 32511, Egypt

Tài liệu tham khảo

Fang, 1984, An efficient flow-injection system with on-line ion-exchange preconcentration for the determination of trace amounts of heavy metals by atomic absorption spectrometry, Anal. Chim. Acta, 164, 23, 10.1016/S0003-2670(00)85614-7 Uslu, 2018, A novel analytical method for sensitive determination of lead: Hydrogen assisted T-shape slotted quartz tube-atom trap-flame atomic absorption spectrometry, Microchem. J., 137, 155, 10.1016/j.microc.2017.10.015 Mounteney, 2018, Heavy mineral analysis by ICP-AES a tool to aid sediment provenancing, J. Geochem. Explor., 184, 1, 10.1016/j.gexplo.2017.10.007 Karami, 2004, On-line preconcentration and simultaneous determination of heavy metal ions by inductively coupled plasma-atomic emission spectrometry, Anal. Chim. Acta, 509, 89, 10.1016/j.aca.2003.12.022 Wang, 2003, Anal. Chim. Acta, 499, 139, 10.1016/S0003-2670(03)00509-9 Beck, 2002, Analysis for Cd, Cu, Ni, Zn, and Mn in estuarine water by inductively coupled plasma mass spectrometry coupled with an automated flow injection system, Anal. Chim. Acta, 455, 11, 10.1016/S0003-2670(01)01561-6 Cobelo-Garcıa, 2004, Chemical speciation of dissolved copper, lead and zinc in a riacoastal system: the role of resuspended sediments, Anal. Chim. Acta, 524, 109, 10.1016/j.aca.2004.05.085 Moutcine, 2020, Preparation, characterization and simultaneous electrochemical detection toward Cd (II) and Hg(II) of a phosphate/zinc oxide modified carbon paste electrode, Inorg. Chem. Commun., 116, 1, 10.1016/j.inoche.2020.107911 Moutcine, 2020, A novel carbon paste electrode modified by NP-Al2O3 for the electrochemical simultaneous detection of Pb (II) and Hg (II), Diam. Relat. Mater., 104, 1, 10.1016/j.diamond.2020.107747 Hathoot, 2019, Mono and dual hetero-structured M@poly-1,2 diaminoanthraquinone (M = Pt, Pd and Pt/Pd) catalysts for the electrooxidation of small organic fuels in alkaline medium, RSC Adv., 9, 1849, 10.1039/C8RA09342C Hassan, 2019, Voltammetric determination of cadmium(II), lead(II) and copper(II) with a glassy carbon electrode modified with silver nanoparticles deposited on poly(1,8-diaminonaphthalene), Microchim. Acta, 186, 440, 10.1007/s00604-019-3552-0 Hassan, 2014, Simultaneous determination of ascorbic acid, uric acid and glucose using glassy carbon electrode modified by nickel nanoparticles at poly 1, 8-diaminonaphthalene in basic medium, J. Electroanal. Chem., 728, 123, 10.1016/j.jelechem.2014.06.007 Rocha, 2007, Evaluation of nanometer thick mercury film electrodes for stripping chronopotentiometry, J. Electroanal. Chem., 610, 37, 10.1016/j.jelechem.2007.06.018 Kefala, 2003, A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair, Talanta, 61, 603, 10.1016/S0039-9140(03)00350-3 Economou, 2005, Bismuth-film electrodes: recent developments and potentialities for electroanalysis, TrAC Trends Anal. Chem., 24, 334, 10.1016/j.trac.2004.11.006 Wang, 2011, Glassy carbon electrode modified by conductive polyaniline coating for determination of trace lead and cadmium ions in acetate buffer solution, Thin Solid Films, 519, 5285, 10.1016/j.tsf.2011.01.176 Vu, 2014, Anodic stripping voltammetric determination of Cd2+ and Pb2+ using interpenetrated MWCNT/P1,5-DAN as an enhanced sensing interface, Ionics, 21, 571, 10.1007/s11581-014-1199-8 Nguyen, 2016, One-step Electrosynthesis of Poly(1,5-diaminonaphthalene)/Graphene Nanocomposite as Platform for Lead Detection in Water, Electroanalysis, 28, 1907, 10.1002/elan.201501075 Promphet, 2015, An electrochemical sensor based on graphene/polyaniline/polystyrene nanoporous fibers modified electrode for simultaneous determination of lead and cadmium, Sensors Actuators B Chem., 207, 526, 10.1016/j.snb.2014.10.126 Hassan, 2018, Novel Sensor Based on Poly (1,2-Diaminoanthraquinone) for Individual and Simultaneous Anodic Stripping Voltammetry of Cd2+, Pb2+, Cu2+ and Hg2+, Electroanalysis, 30, 1155, 10.1002/elan.201800097 Wei Zhu, 2006, Anodic Stripping Voltammetry Determination of Pb(II) and Cd(II) at a Bismuth/Poly(aniline) Film Electrode, Anal. Lett., 39, 2273, 10.1080/00032710600755538 Chen, 2012, Square wave anodic stripping voltammetric determination of Cd and Pb ions at a Bi/Nafion/thiolated polyaniline/glassy carbon electrode, Electrochem. Commun., 15, 34, 10.1016/j.elecom.2011.11.021 Salih, 2017, Electrochemical detection of lead (II) at bismuth/Poly(1,8-diaminonaphthalene) modified carbon paste electrode, Arab. J. Chem., 10, 596, 10.1016/j.arabjc.2015.08.021 Palisoc, 2019, Electrochemical detection of lead and cadmium in UHT-processed milk using bismuth nanoparticles/Nafion®-modified pencil graphite electrode, Sens. Bio-Sens. Res., 23, 1 Palisoc, 2019, Fabrication of a bismuth nanoparticle/Nafion modified screen-printed graphene electrode for in situ environmental monitoring, Anal. Methods, 11, 1591, 10.1039/C9AY00221A Palisoc, 2018, Determination of Heavy Metals in Herbal Food Supplements using Bismuth/Multi-walled Carbon Nanotubes/Nafion modified Graphite Electrodes sourced from Waste Batteries, Sci. Rep., 9, 18491, 10.1038/s41598-019-54589-x Lu, 2018, Facile one-step fabrication of a novel 3D honeycomb-like bismuth nanoparticles decorated N-doped carbon nanosheet frameworks: Ultrasensitive electrochemical sensing of heavy metal ions, Electrochim. Acta, 266, 94, 10.1016/j.electacta.2018.01.188 Ouyang, 2011, Simultaneous stripping detection of Zn (II), Cd (II) and Pb (II) using a bimetallic Hg–Bi/single-walled carbon nanotubes composite electrode, J. Electroanal. Chem., 656, 78, 10.1016/j.jelechem.2011.01.006 Zhang, 2020, Simultaneous detection of trace Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry using a bismuth oxycarbide/nafion electrode, Inorg. Chem. Commun., 111, 1, 10.1016/j.inoche.2019.107672 Perez-Rafols, 2016, New approaches to antimony film screen-printed electrodes using carbon-based nanomaterials substrates, Anal. Chim. Acta, 916, 17, 10.1016/j.aca.2016.03.003 Zhao, 2017, Simultaneous determination of trace Cd(II) and Pb(II) based on Bi/Nafion/reduced graphene oxide-gold nanoparticle nanocomposite film-modified glassy carbon electrode by one-step electrodeposition, Ionics, 23, 767, 10.1007/s11581-016-1843-6 Shrivastava, 2011, Methods for the determination of limit of detection and limit of quantitation of the analytical methods, Chron. Young Sci., 2, 21, 10.4103/2229-5186.79345 Shrivastava, 2011, Methods for the determination of limit of detection and limit of quantitation of the analytical methods, Chron. Young Sci., 2, 21, 10.4103/2229-5186.79345 Wu, 2008, Simultaneous measurement of Pb, Cd and Zn using differential pulse anodic stripping voltammetry at a bismuth/poly(p-aminobenzene sulfonic acid) film electrode, Sensors Actuators B Chem., 133, 677, 10.1016/j.snb.2008.04.001 Chamjangali, 2015, A voltammetric sensor based on the glassy carbon electrode modified with multi-walled carbon nanotube/poly(pyrocatechol violet)/bismuth film for determination of cadmium and lead as environmental pollutants, Sensors Actuators B Chem., 216, 384, 10.1016/j.snb.2015.04.058 Sosa, 2014, Sputtered bismuth screen-printed electrode: A promising alternative to other bismuth modifications in the voltammetric determination of Cd(II) and Pb(II) ions in groundwater, Talanta, 119, 348, 10.1016/j.talanta.2013.11.032 Ouyang, 2011, Simultaneous stripping detection of Zn(II), Cd(II) and Pb(II) using a bimetallic Hg-Bi/single-walled carbon nanotubes composite electrode, J. Electroanal. Chem., 656, 78, 10.1016/j.jelechem.2011.01.006 Lazanas, 2020, 2D bismuthene/graphene modified electrodes for the ultra-sensitive stripping voltammetric determination of lead and cadmium, Electrochim. Acta, 336, 135726, 10.1016/j.electacta.2020.135726 Petrovic, 2019, Trace level voltammetric determination of Zn(II) in selected nutrition related samples by bismuth-oxychloride-multiwalled carbon nanotube composite based electrode, Microchem. J., 146, 178, 10.1016/j.microc.2018.12.053 Jiokeng, 2017, Sensitive stripping voltammetry detection of Pb (II) at a glassy carbon electrode modified with an amino-functionalized attapulgite, Sensors Actuators B Chem., 242, 1027, 10.1016/j.snb.2016.09.150 Zhao, 2017, Simultaneous and Sensitive Detection of Cd(II) and Pb(II) Using a Novel Bismuth Film/Ordered Mesoporous Carbon-molecular Wire Modified Graphite Carbon Paste Electrode, Electroanalysis, 29, 497, 10.1002/elan.201600430 Lee, 2016, Voltammetric determination of trace heavy metals using an electrochemically deposited graphene/bismuth nanocomposite film-modified glassy carbon electrode, J. Electroanal. Chem., 766, 120, 10.1016/j.jelechem.2016.02.003