Silver nanoparticle doped graphene-based impedimetric biosensor towards sensitive detection of procalcitonin

Materials Chemistry and Physics - Tập 297 - Trang 127339 - 2023
Faysal Selimoğlu1, Bahri Gür2, Muhammed Emre Ayhan3, Fatma Gür4, Golap Kalita5, Masaki Tanemura6, Mehmet Hakkı Alma7
1Department of Biotechnology, Faculty of Science, Necmettin Erbakan University, Konya, Turkiye
2Department of Biochemistry, Faculty of Sciences and Arts, Iğdır University, Iğdır, Turkiye
3Department of Metallurgical and Materials Engineering, Faculty of Engineering, Necmettin Erbakan University, Konya, Turkiye
4Department of Medical Services and Techniques, Health Services Vocational School, Atatürk University, Erzurum, Turkiye
5C's Techno Inc., Co-operative Research Center for Advanced Technology, Nagoya Science Park, Moriyama-ku, Nagoya, 4630003, Japan
6Department of Physical Science and Engineering, Nagoya Institute of Technology, Nagoya, Japan
7Department of the Biosystems Engineering, Faculty of Agriculture, Iğdır University, Iğdır, Turkiye

Tài liệu tham khảo

Kemmler, 2014, Biochip point-of-care device for sepsis diagnostics, Sensor. Actuator. B Chem., 192, 205, 10.1016/j.snb.2013.10.003 Cohen, 2004, Diagnosis of infection in sepsis: an evidence-based review, Crit. Care Med., 32, S466, 10.1097/01.CCM.0000145917.89975.F5 Rowland, 2015, Procalcitonin: potential role in diagnosis and management of sepsis, Adv. Clin. Chem., 68, 71, 10.1016/bs.acc.2014.11.005 Anand, 2015, Procalcitonin as a rapid diagnostic biomarker to differentiate between culture-negative bacterial sepsis and systemic inflammatory response syndrome: a prospective, observational, cohort study, J. Crit. Care, 30, 10.1016/j.jcrc.2014.08.017 Becker, 2008, Procalcitonin assay in systemic inflammation, infection, and sepsis: clinical utility and limitations, Crit. Care Med., 36, 941, 10.1097/CCM.0B013E318165BABB Li, 2014, A nanobody-based electro chemiluminescent immunosensor for sensitive detection of human procalcitonin, Analyst, 139, 3718, 10.1039/c4an00626g Sener, 2013, Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor, Analyst, 138, 6422, 10.1039/c3an00958k Krämer, 2011, Multi-parameter determination of TNFα, PCT and CRP for point-of-care testing, Analyst, 136, 692, 10.1039/C0AN00699H Kibe, 2011, Diagnostic and prognostic biomarkers of sepsis in critical care, J. Antimicrob. Chemother., 66, ii33, 10.1093/jac/dkq523 Tang, 2007, Accuracy of procalcitonin for sepsis diagnosis in critically ill patients: systematic review and meta-analysis, Lancet Infect. Dis., 7, 210, 10.1016/S1473-3099(07)70052-X Dahaba, 2006, Procalcitonin for early prediction of survival outcome in postoperative critically ill patients with severe sepsis, Br. J. Addiction: Br. J. Anaesth., 97, 503 Lim, 2017, An electrochemical biosensor for detection of the sepsis-related biomarker procalcitonin, RSC Adv., 7, 36562, 10.1039/C7RA06553A Munack, 2006 Tang, 2006, Carbon nanotube DNA sensor and sensing mechanism, Nano Lett., 6, 1632, 10.1021/nl060613v Mukhopadhyay, 2005, Cantilever sensor for nanomechanical detection of specific protein conformations, Nano Lett., 5, 2385, 10.1021/nl051449z Wang, 1997, DNA electrochemical biosensors for environmental monitoring. A review, Anal. Chim. Acta, 347, 1, 10.1016/S0003-2670(96)00598-3 Liu, 2008, An enzyme-based E-DNA sensor for sequence-specific detection of femtomolar DNA targets, J. Am. Chem. Soc., 130, 6820, 10.1021/ja800554t Lobo, 1997, Amperometric biosensors based on NAD (P)‐dependent dehydrogenase enzymes, Electroanalysis, 9, 191, 10.1002/elan.1140090302 Zhang, 2004, Calorimetric biosensors with integrated microfluidic channels, Biosens. Bioelectron., 19, 1733, 10.1016/j.bios.2004.01.009 Zhang, 2011, An ultrasensitive and low-cost graphene sensor based on layer-by-layer nano self-assembly, Appl. Phys. Lett., 98 Kwon, 2012, Flexible FET-type VEGF aptasensor based on nitrogen-doped graphene converted from conducting polymer, ACS Nano, 6, 1486, 10.1021/nn204395n Kwak, 2012, Flexible glucose sensor using CVD-grown graphene-based field effect transistor, Biosens. Bioelectron., 37, 82, 10.1016/j.bios.2012.04.042 Huang, 2011, Graphene-based biosensors for detection of bacteria and their metabolic activities, J. Mater. Chem., 21, 12358, 10.1039/c1jm11436k Yang, 2010, Carbon nanomaterials in biosensors: should you use nanotubes or graphene, Angew. Chem. Int. Ed., 49, 2114, 10.1002/anie.200903463 Mannoor, 2012, Graphene-based wireless bacteria detection on tooth enamel, Nat. Commun., 3, 1, 10.1038/ncomms1767 Akhavan, 2011, Wrapping bacteria by graphene nanosheets for isolation from environment, reactivation by sonication, and inactivation by near-infrared irradiation, J. Phys. Chem. B, 115, 6279, 10.1021/jp200686k Akhavan, 2012, Escherichia coli bacteria reduce graphene oxide to bactericidal graphene in a self-limiting manner, Carbon, 50, 1853, 10.1016/j.carbon.2011.12.035 Akhavan, 2010, Toxicity of graphene and graphene oxide nanowalls against bacteria, ACS Nano, 4, 5731, 10.1021/nn101390x Tu, 2013, Destructive extraction of phospholipids from Escherichia coli membranes by graphene nanosheets, Nat. Nanotechnol., 8, 594, 10.1038/nnano.2013.125 Basu, 2014, Graphene based E. coli sensor on flexible acetate sheet, Sensor. Actuator. B Chem., 190, 342, 10.1016/j.snb.2013.08.080 Yao, 2014, All-optical Mach–Zehnder interferometric NH3 gas sensor based on graphene/microfiber hybrid waveguide, Sensor. Actuator. B Chem., 194, 142, 10.1016/j.snb.2013.12.085 He, 2010, A graphene nanoprobe for rapid, sensitive, and multicolor fluorescent DNA analysis, Adv. Funct. Mater., 20, 453, 10.1002/adfm.200901639 Zhang, 2013, A novel graphene-DNA biosensor for selective detection of mercury ions, Biosens. Bioelectron., 48, 180, 10.1016/j.bios.2013.04.013 Nguyen, 2012, Graphene interfaced with biological cells: opportunities and challenges, J. Phys. Chem. Lett., 3, 1024, 10.1021/jz300033g Li, 2014, Ultrafast all-optical graphene modulator, Nano Lett., 14, 955, 10.1021/nl404356t Yao, 2015, Graphene-based D-shaped polymer FBG for highly sensitive erythrocyte detection, IEEE Photon. Technol. Lett., 27, 2399, 10.1109/LPT.2015.2466614 Ayhan, 2021, CVD graphene-based flexible and transparent SERS substrate towards L-tyrosine detection, Microelectron. Eng., 241, 10.1016/j.mee.2021.111546 Kim, 2016, Robust graphene wet transfer process through low molecular weight polymethylmethacrylate, Carbon, 98, 352, 10.1016/j.carbon.2015.11.027 Gür, 2019, Molibden oksit, Pluronic® F127 ve mantarın lityum tetraborat/ITO elektrotların kapasitif özelliklerine etkilerinin incelenmesi, Afyon Kocatepe Üniversitesi Fen Ve Mühendislik Bilimleri Dergisi, 21, 196 Gür, 2020, Determination of the pH-dependent immobilization efficacy of α-glycosidase and its catalytic performance on SnO2: Sb/ITO thin films, Biochem. Eng. J., 163, 10.1016/j.bej.2020.107758 Gür. B, Ayhan. M.E, Türkhan. A, Gür. F, Kaya. E.D, A facile immobilization of polyphenol oxidase enzyme on graphene oxide and reduced graphene oxide thin films: An insight into in-vitro activity measurements and characterization. Colloids Surf. A Physicochem. Eng. Asp. 562 179–185 10.1016/j.colsurfa.2018.11.041. Ou, 2010, Tribology study of reduced graphene oxide sheets on silicon substrate synthesized via covalent assembly, Langmuir, 26, 15830, 10.1021/la102862d Yang, 2019, Construction of well-ordered electrochemiluminescence sensing interface using peptide-based specific antibody immobilizer and N-(aminobutyl)-N-(ethylisoluminol) functionalized ferritin as signal indicator for procalcitonin analysis, Biosens. Bioelectron., 142, 10.1016/j.bios.2019.111562 Alam, 2021, Electrochemical detection of 2-nitrophenol with BaO nanorods modified glassy carbon electrode, Chem. Asian J., 10.1002/asia.202100250 Gür, 2019, Preparation of bio-electrodes via Langmuir-Blodgett technique for pharmaceutical and waste industries and their biosensor application, Colloids Surf. A Physicochem. Eng. Asp., 583, 10.1016/j.colsurfa.2019.124005 Aydın, 2017, A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNFα in human saliva and serum samples, Biosens. Bioelectron., 97, 169, 10.1016/j.bios.2017.05.056 Parnianchi, 2022, Ultrasensitive electrochemical sensor based on molecular imprinted polymer and ferromagnetic nanocomposite for bilirubin analysis in the saliva and serum of newborns, Microchem. J., 179, 10.1016/j.microc.2022.107474 Grewal, 2014, Nano-yeast–scFv probes on screen-printed gold electrodes for detection of Entamoeba histolytica antigens in a biological matrix, Biosens. Bioelectron., 55, 417, 10.1016/j.bios.2013.12.043 Bayraktutan, 2022, A new FRET-based functional chemosensor for fluorometric detection of Fe3+and its validation through in silico studies, J. Mol. Struct., 1256, 10.1016/j.molstruc.2022.132448 Huang, 2008, Impedance biosensor for peanut protein Ara h 1, Anal. Chem., 80, 9157, 10.1021/ac801048g Lasia, 2014 Katz, 2003, Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: routes to impedimetric immunosensors, DNA‐sensors, and enzyme biosensors, Electroanalysis: An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis, 15, 913, 10.1002/elan.200390114 Suni, 2008, Impedance methods for electrochemical sensors using nanomaterials, TrAC, Trends Anal. Chem., 27, 604, 10.1016/j.trac.2008.03.012 Aydemir, 2016, Conducting polymer based electrochemical biosensors, Phys. Chem. Chem. Phys., 18, 8264, 10.1039/C5CP06830D Wiedermann, 2002, Migration of human monocytes in response to procalcitonin, Crit. Care Med., 30, 1112, 10.1097/00003246-200205000-00025 Schuetz, 2011, Procalcitonin for diagnosis of infection and guide to antibiotic decisions: past, present and future, BMC Med., 9, 1, 10.1186/1741-7015-9-107 Gendrel, 1997, Measurement of procalcitonin levels in children with bacterial or viral meningitis, Clin. Infect. Dis., 24, 1240, 10.1086/513633 van der Does, 2018, Procalcitonin-guided antibiotic therapy in patients with fever in a general emergency department population: a multicentre non-inferiority randomized clinical trial (HiTEMP study), Clin. Microbiol. Infect., 24, 1282, 10.1016/j.cmi.2018.05.011 Bloos, 2014, Rapid diagnosis of sepsis, Virulence, 5, 154, 10.4161/viru.27393 Liu, 2019, Quantitative detection of procalcitonin using an electrochemical immunosensor based on MoO3/Au@rGO nanocomposites, Analyst, 144, 6968, 10.1039/C9AN01721F Yang, 2016, Electrochemical activity and electrocatalytic property of cobalt phthalocyanine nanoparticles-based immunosensor for sensitive detection of procalcitonin, Sensor. Actuator. B Chem., 227, 212, 10.1016/j.snb.2015.08.109 Xu, 2021, A dual-mode label-free electrochemical immunosensor for ultrasensitive detection of procalcitonin based on gC 3 N 4-NiCo 2 S 4-CNTs-Ag NPs, Analyst, 146, 3169, 10.1039/D1AN00372K Li, 2018, Label-free sandwich imaging ellipsometry immunosensor for serological detection of procalcitonin, Anal. Chem., 90, 8002, 10.1021/acs.analchem.8b00888 Wang, 2020, Development of a novel chemiluminescence immunoassay for the detection of procalcitonin, J. Immunol. Methods, 484–485