Sensitivity-Enhanced Fourier Transform Mid-Infrared Spectroscopy Using a Supercontinuum Laser Source

Applied Spectroscopy - Tập 74 Số 4 - Trang 485-493 - 2020
Ivan Zorin1, Jakob Kilgus1, Kristina Duswald1, Bernhard Lendl2, Bettina Heise1, Markus Brandstetter1
1Research Center for Non-Destructive Testing, Linz, Austria
2Institute for Chemical Technologies and Analytics, TU Wien, Vienna, Austria

Tóm tắt

Fourier transform infrared (FT-IR) spectrometers have been the dominant technology in the field of mid-infrared (mid-IR) spectroscopy for decades. Supercontinuum laser sources operating in the mid-IR spectral region now offer the potential to enrich the field of FT-IR spectroscopy due to their distinctive properties, such as high-brightness, broadband spectral coverage and enhanced stability. In our contribution, we introduce this advanced light source as a replacement for conventional thermal emitters. Furthermore, an approach to efficient coupling of pulsed mid-IR supercontinuum sources to FT-IR spectrometers is proposed and considered in detail. The experimental part is devoted to pulse-to-pulse energy fluctuations of the applied supercontinuum laser, performance of the system, as well as the noise and long-term stability. Comparative measurements performed with a conventional FT-IR instrument equipped with a thermal emitter illustrate that similar noise levels can be achieved with the supercontinuum-based system. The analytical performance of the supercontinuum-based FT-IR spectrometer was tested for a concentration series of aqueous formaldehyde solutions in a liquid flow cell (500 µm path length) and compared with the conventional FT-IR (130 µm path length). The results show a four-times-enhanced detection limit due to the extended path length enabled by the high brightness of the laser. In conclusion, FT-IR spectrometers equipped with novel broadband mid-IR supercontinuum lasers could outperform traditional systems providing superior performance, e.g., interaction path lengths formerly unattainable, while maintaining low noise levels known from highly stable thermal emitters.

Từ khóa


Tài liệu tham khảo

Günzler H., 2002, IR Spectroscopy: An Introduction

10.1017/CBO9780511750465

10.3390/app8050707

10.1016/j.infrared.2018.04.008

10.1039/C7CS00403F

10.1021/acs.analchem.8b01632

10.1364/OL.28.000944

10.1177/0003702817746696

10.1364/OE.26.030644

10.1364/OPTICA.5.000378

10.1063/1.4985263

10.1364/OE.26.012169

10.1364/OE.26.033428

10.1038/srep19284

10.1364/OE.22.018824

10.1088/1612-2011/11/7/075601

10.1364/OE.27.002036

10.1364/JOSAB.36.00A161

10.1364/OE.22.024384

10.1364/OL.42.003458

10.1364/OE.22.019169

10.1364/OPTICA.2.000797

10.1364/OL.41.002117

10.1002/lpor.201700005

10.1038/nphoton.2014.213

10.1063/1.4961655

10.1364/OL.33.000285

10.1007/s00340-003-1201-z

10.1016/j.atmosenv.2010.05.044

10.1021/es00065a013

World Health Organization, 2005, Formaldehyde in Drinking-Water

10.1177/0192623312466459

10.1016/0278-6915(89)90001-X

10.1111/j.1600-0773.1991.tb01290.x

Sadun A.A., 2002, J. Neurol., Neurosurg. Psychiatry, 72, 423

10.1016/j.arabjc.2011.02.005

10.1016/j.molliq.2006.12.002

10.1007/s00340-012-5080-z

10.1007/BF00425997

Long G.L., 1983, Anal. Chem, 55, 712A

10.1364/OL.43.000296

10.1364/OL.41.003201

10.1038/s41467-019-09590-3