Screw orientation and plate type (variable- vs. fixed-angle) effect strength of fixation for in vitro biomechanical testing of the Synthes CSLP

The Spine Journal - Tập 8 - Trang 717-722 - 2008
Christian P. DiPaola1, Justin A. Jacobson2, Hani Awad1, Bryan P. Conrad3, Glenn R. Rechtine1
1University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, NY 14642, USA
2University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, NY, 14642, USA
3University of Florida Medical Center, P.O. Box 100246, Gainesville, FL, 32610, USA

Tài liệu tham khảo

Steinmetz, 2005, Subsidence and dynamic cervical spine stabilization, 1477 Leventhal, 2003, Fractures, dislocations and fracture-dislocations of the spine, 1638 Papadopoulos, 2004, Anterior plate fixation for cervical discectomy and fusion, 184 Conrad, 2005, Biomechanical evaluation of the pullout strength of cervical screws, J Spinal Disord Tech, 18, 506, 10.1097/01.bsd.0000140196.99995.65 DiPaola C, Jacobson J, Awad H, Conrad B, Rechtine G. Screw pull-out force is dependent on screw orientation in an anterior cervical plate construct. J Spinal Disord Tech, in press. Moftakhar, 2004, Anterior cervical plates: a historical perspective, Neurosurg Focus, 16, E8, 10.3171/foc.2004.16.1.9 Asnis, 1996, Cancellous bone screw thread design and holding power, J Orthop Trauma, 10, 462, 10.1097/00005131-199610000-00003 Brown, 2000, Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws, J Orthop Res, 18, 307, 10.1002/jor.1100180220 Thompson, 1997, Pullout strengths of cannulated and noncannulated cancellous bone screws, Clin Orthop Relat Res, 241 Dvorak, 2005, Anterior cervical plate fixation: a biomechanical study to evaluate the effects of plate design, endplate preparation, and bone mineral density, Spine, 30, 294, 10.1097/01.brs.0000152154.57171.92 Hitchon, 2003, Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws, Spine, 28, 9, 10.1097/00007632-200301010-00004 Ryken, 1995, Assessment of unicortical and bicortical fixation in a quasistatic cadaveric model. Role of bone mineral density and screw torque, Spine, 20, 1861, 10.1097/00007632-199509000-00003 Seybold, 1999, Characteristics of unicortical and bicortical lateral mass screws in the cervical spine, Spine, 24, 2397, 10.1097/00007632-199911150-00018 Grubb, 1998, Biomechanical evaluation of anterior cervical spine stabilization, Spine, 23, 886, 10.1097/00007632-199804150-00009 Pitzen, 2002, Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating, Eur Spine J, 11, 494, 10.1007/s00586-002-0447-1 Ryken, 1995, Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screws, J Neurosurg, 83, 325, 10.3171/jns.1995.83.2.0324 Ogon, 1996, Comparison between single-screw and triangulated, double-screw fixation in anterior spine surgery. A biomechanical test, Spine, 21, 2728, 10.1097/00007632-199612010-00005 Rodriguez-Olaverri, 2005, The effect of end screw orientation on the stability of anterior instrumentation in cyclic lateral bending, Spine J, 5, 554, 10.1016/j.spinee.2005.03.014 Horton, 1996, Strength of fixation of anterior vertebral body screws, Spine, 21, 439, 10.1097/00007632-199602150-00007