Role of gastrointestinal ultrasound in image-guided radiation therapy: A review

Qiuchen Lu1, Daoning Guo1, Yunfeng Wei1, Jiali Zheng1, Juan Li1
1Department of Ultrasound Medicine, Mianyang Central Hospital, School of Medicine, University of Electronic Science and Technology of China, Mianyang, 621000, China

Tài liệu tham khảo

Abbas, 2014, Motion management in gastrointestinal cancers, Journal of Gastrointestinal Oncology, 5, 223 Abdelfatah, 2019, Fiducial placement for recurrent gastric cancer, Arab J Gastroenterol, 20, 56, 10.1016/j.ajg.2019.01.007 Ammar, 2010, Fiducial placement for stereotactic radiation by using EUS: Feasibility when using a marker compatible with a standard 22-gauge needle, Gastrointestinal Endoscopy, 71, 630, 10.1016/j.gie.2009.11.023 Bhutani, 2019, Endoscopic ultrasound–guided fiducial placement for gastrointestinal malignancies, Gastroenterology and Hepatology, 15, 167 Boda-Heggemann, 2009, Accuracy of ultrasound-based image guidance for daily positioning of the upper abdomen: An online comparison with cone beam CT, International Journal of Radiation Oncology, Biology, Physics, 74, 892, 10.1016/j.ijrobp.2009.01.061 Buzurovic, 2010, Tumor motion prediction and tracking in adaptive radiotherapy, 273 Campbell, 2013, A short history of sonography in obstetrics and gynaecology, Facts Views Vis ObGyn, 5, 213 Carrara, 2016, The golden compass to the depths, Gastroenterology, 151, e7, 10.1053/j.gastro.2016.07.006 Chandnani, 2020, EUS-Guided fiducial placement for pancreatobiliary malignancies: Safety, infection risk, and use of peri-procedural antibiotics, Endoscopy International Open, 8, E179, 10.1055/a-1068-9128 Chandran, 2014, A pilot study of EUS-guided fiducial insertion for the multidisciplinary management of gastric cancer, Endoscopy International Open, 2, E153, 10.1055/s-0034-1377523 Chan, 2022, EUS-Guided fiducial marker insertion for radiotherapy in advanced esophageal carcinoma: Submucosal insertion may lead to less migration when compared to intratumoral insertion, Surgical Endoscopy, 36, 1666, 10.1007/s00464-021-08711-8 Choi, 2014, Fiducial placement for stereotactic body radiation therapy under only endoscopic ultrasonography guidance in pancreatic and hepatic malignancy: Practical feasibility and safety, Gut Liver, 8, 88, 10.5009/gnl.2014.8.1.88 De Molo, 2013, Pancreas mobile, Zeitschrift für Gastroenterologie, 51, 1165, 10.1055/s-0033-1335185 Dhadham, 2016, Endoscopic ultrasound-guided fiducial marker placement for image-guided radiation therapy without fluoroscopy: Safety and technical feasibility, Endoscopy International Open, 4, E378, 10.1055/s-0042-100720 Dietrich, 2020, Modern ultrasound imaging of pancreatic tumors, Ultrasonography, 39, 105, 10.14366/usg.19039 DiMaio, 2010, EUS-guided fiducial placement for image-guided radiation therapy in GI malignancies by using a 22-gauge needle (with), Gastrointestinal Endoscopy, 71, 1204, 10.1016/j.gie.2010.01.003 Drever, 2007, Daily quality assurance phantom for ultrasound image guided radiation therapy, Journal of Applied Clinical Medical Physics, 8, 126, 10.1120/jacmp.v8i3.2467 van Dyk, 2015, Assessing changes to the brachytherapy target for cervical cancer using a single MRI and serial ultrasound, Brachytherapy, 14, 889, 10.1016/j.brachy.2015.04.011 Ellsmere, 2007, EUS-guided radiotherapy fiducials for upper gastrointestinal malignancies, Gastrointestinal Endoscopy, 65, AB208, 10.1016/j.gie.2007.03.420 Fajardo, 2014, EUS-guided fiducial markers placement with a 22-gauge needle for image-guided radiation therapy in pancreatic cancer, Gastrointestinal Endoscopy, 79, 851, 10.1016/j.gie.2013.12.027 Fenster, 2014, 3D ultrasound imaging in image-guided intervention, 6151 Fernandez, 2013, Stability of endoscopic ultrasound-guided fiducial marker placement for esophageal cancer target delineation and image-guided radiation therapy, Pract Radiat Oncol, 3, 32, 10.1016/j.prro.2012.02.006 Fontanarosa, 2015, Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management, Physics in Medicine and Biology, 60, R77, 10.1088/0031-9155/60/3/R77 Fuller, 2006, Image-guided intensity-modulated radiation therapy for gallbladder carcinoma, Radiotherapy & Oncology, 81, 65, 10.1016/j.radonc.2006.08.013 Fung, 2006, Ultrasound-based guidance of intensity-modulated radiation therapy, Medical Dosimetry, 31, 20, 10.1016/j.meddos.2005.12.011 Fuss, 2004, Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies, International Journal of Radiation Oncology, Biology, Physics, 59, 1245, 10.1016/j.ijrobp.2003.12.030 Fuss, 2007, Image-guided intensity-modulated radiotherapy for pancreatic carcinoma, Gastrointest Cancer Res GCR, 1, 2 Ghassemi, 2009, EUS-guided placement of fiducial markers using a 22-gauge needle, Gastrointestinal Endoscopy, 69, AB337, 10.1016/j.gie.2009.03.980 Han, 2013, Trends in the utilization of brachytherapy in cervical cancer in the United States, International Journal of Radiation Oncology, Biology, Physics, 87, 111, 10.1016/j.ijrobp.2013.05.033 Hoyer, 2005, Phase-II study on stereotactic radiotherapy of locally advanced pancreatic carcinoma, Radiotherapy & Oncology, 76, 48, 10.1016/j.radonc.2004.12.022 Imura, 2005, Insertion and fixation of fiducial markers for setup and tracking of lung tumors in radiotherapy, International Journal of Radiation Oncology, Biology, Physics, 63, 1442, 10.1016/j.ijrobp.2005.04.024 Khashab, 2012, Comparative analysis of traditional and coiled fiducials implanted during EUS for pancreatic cancer patients receiving stereotactic body radiation therapy, Gastrointestinal Endoscopy, 76, 962, 10.1016/j.gie.2012.07.006 Kim, 2018, A patient-specific three-dimensional couplant pad for ultrasound image-guided radiation therapy: A feasibility study, Radiation Oncology, 13, 1, 10.1186/s13014-018-1098-7 Langen, 2003, Evaluation of ultrasound-based prostate localization for image-guided radiotherapy, International Journal of Radiation Oncology, Biology, Physics, 57, 635, 10.1016/S0360-3016(03)00633-3 Langner, 2009, Accuracy in the localization of thoracic and abdominal tumors using respiratory displacement, velocity, and phase, Medical Physics, 36, 386, 10.1118/1.3049595 Law, 2013, Endoscopic ultrasound (EUS)-guided fiducial placement allows localization of small neuroendocrine tumors during parenchymal-sparing pancreatic surgery, Surgical Endoscopy, 27, 3921, 10.1007/s00464-013-2975-7 Lim, 2012, Outcomes of chemoradiotherapy in cervical cancer—the Western Australian experience, International Journal of Radiation Oncology, Biology, Physics, 82, 1431, 10.1016/j.ijrobp.2011.04.047 Lim, 2017, Patterns of practice survey for brachytherapy for cervix cancer in Australia and New Zealand, Jordan Medical Imaging Radiation Oncology, 61, 674, 10.1111/1754-9485.12614 Machicado, 2019, Endoscopic ultrasound placement of preloaded fiducial markers shortens procedure time compared to back-loaded markers, Clinical Gastroenterology and Hepatology, 17, 2749, 10.1016/j.cgh.2019.04.046 Machiels, 2015, Endoscopy/EUS-guided fiducial marker placement in patients with esophageal cancer: A comparative analysis of 3 types of markers, Gastrointestinal Endoscopy, 82, 641, 10.1016/j.gie.2015.03.1972 Majumder, 2013, Endoscopic ultrasound–guided pancreatic fiducial placement: How important is ideal fiducial geometry?, Pancreas, 42, 692, 10.1097/MPA.0b013e3182864559 Mampuya, 2013, Interfraction variation in lung tumor position with abdominal compression during stereotactic body radiotherapy, Medical Physics, 40, 10.1118/1.4819940 Moningi, 2015, Analysis of fiducials implanted during EUS for patients with localized rectal cancer receiving high-dose rate endorectal brachytherapy, Gastrointestinal Endoscopy, 81, 765, 10.1016/j.gie.2014.11.004 Nesvacil, 2016, Combining transrectal ultrasound and CT for image-guided adaptive brachytherapy of cervical cancer: Proof of concept, Brachytherapy, 15, 839, 10.1016/j.brachy.2016.08.009 O'Neill, 2016, Fiducial marker guided prostate radiotherapy: A review, British Journal of Radiology, 89, 10.1259/bjr.20160296 Orton, 2005, TU-EE-A4-01: Clinical experience with a 3-D ultrasound prostate localization system, Medical Physics, 32, 10.1118/1.1999717 Ozhasoglu, 2002, Issues in respiratory motion compensation during external-beam radiotherapy, International Journal of Radiation Oncology, Biology, Physics, 52, 1389, 10.1016/S0360-3016(01)02789-4 Packard, 2015, Use of implanted gold fiducial markers with MV-CBCT image-guided IMRT for pancreatic tumours, Jordan Medical Imaging Radiation Oncology, 59, 499, 10.1111/1754-9485.12294 Park, 2010, EUS-Guided gold fiducial insertion for image-guided radiation therapy of pancreatic cancer: 50 successful cases without fluoroscopy, Gastrointestinal Endoscopy, 71, 513, 10.1016/j.gie.2009.10.030 Pfau, 2005, A novel use of endoscopic clips in the treatment planning for radiation therapy (XRT) of esophageal cancer, Journal of Clinical Gastroenterology, 39, 372, 10.1097/01.mcg.0000159227.40166.01 Phan, 2019, Performance of a new preloaded fiducial needle to guide radiation therapy of upper gastrointestinal cancers, Endoscopy, 51, 463, 10.1055/a-0800-0033 Pishvaian, 2006, EUS-guided fiducial placement for CyberKnife radiotherapy of mediastinal and abdominal malignancies, Gastrointestinal Endoscopy, 64, 412, 10.1016/j.gie.2006.01.048 Purdy, 2004, Current ICRU definitions of volumes: Limitations and future directions, 27 Rao, 2015, Routine use of ultrasound guided tandem placement in intracavitary brachytherapy for the treatment of cervical cancer–a South Indian institutional experience, Journal of Contemporary Brachytherapy, 7, 352, 10.5114/jcb.2014.55115 Rigter, 2019, EUS-Guided fiducial marker placement for radiotherapy in rectal cancer: Feasibility of two placement strategies and four fiducial types, Endoscopy International Open, 7, E1357, 10.1055/a-0958-2148 Robin, 2016, Disparities in standard of care treatment and associated survival decrement in patients with locally advanced cervical cancer, Gynecologic Oncology, 143, 319, 10.1016/j.ygyno.2016.09.009 Sanders, 2010, EUS-guided fiducial placement for stereotactic body radiotherapy in locally advanced and recurrent pancreatic cancer, Gastrointestinal Endoscopy, 71, 1178, 10.1016/j.gie.2009.12.020 Schmid, 2016, Transrectal ultrasound for image-guided adaptive brachytherapy in cervix cancer–an alternative to MRI for target definition?, Radiotherapy & Oncology, 120, 467, 10.1016/j.radonc.2016.01.021 Schmid, 2013 Sia, 2013, The use of fiducial markers in image-guided radiotherapy for gastric cancer, Jordan Medical Imaging Radiation Oncology, 57, 626, 10.1111/1754-9485.12084 Stroom, 2002, Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report, Radiotherapy & Oncology, 64, 75, 10.1016/S0167-8140(02)00140-8 Ussui, 2018, EUS-Guided liquid fiducial placement for stereotactic radiotherapy in pancreatic cancer: Feasibility study, Endosc Ultrasound, 7, 135, 10.4103/eus.eus_98_17 Van Dyk, 2014, Comparison of measurements of the uterus and cervix obtained by magnetic resonance and transabdominal ultrasound imaging to identify the brachytherapy target in patients with cervix cancer, International Journal of Radiation Oncology, Biology, Physics, 88, 860, 10.1016/j.ijrobp.2013.12.004 Van Dyk, 2015, Ultrasound use in gynecologic brachytherapy: Time to focus the beam, Brachytherapy, 14, 390, 10.1016/j.brachy.2014.12.001 Varadarajulu, 2011, Antibiotic prophylaxis is recommended for endoscopic ultrasound-guided fiducial placements, Journal of Clinical Gastroenterology, 45, 179, 10.1097/MCG.0b013e3181efb1a7 Varadarajulu, 2010, The use of endoscopic ultrasound-guided gold markers in image-guided radiation therapy of pancreatic cancers: A case series, Endoscopy, 42, 423, 10.1055/s-0029-1243989 Vorwerk, 2009, Gold markers for tumor localization and target volume delineation in radiotherapy for rectal cancer, Strahlentherapie und Onkologie, 185, 127, 10.1007/s00066-009-1928-5 Woo, 2002, A short history of the development of ultrasound in obstetrics and gynecology, Hist Ultrasound Obstet Gynecol, 3, 1 Wunderink, 2010, Potentials and limitations of guiding liver stereotactic body radiation therapy set-up on liver-implanted fiducial markers, International Journal of Radiation Oncology, Biology, Physics, 77, 1573, 10.1016/j.ijrobp.2009.10.040 Yang, 2009, EUS-guided fiducial placement before targeted radiation therapy for prostate cancer, Gastrointestinal Endoscopy, 70, 579, 10.1016/j.gie.2009.03.001 Yang, 2011, EUS-guided fiducial placement after radical prostatectomy before targeted radiation therapy for prostate cancer recurrence, Gastrointestinal Endoscopy, 73, 1302, 10.1016/j.gie.2011.01.045 Yao, 2015, Positioning accuracy during VMAT of gynecologic malignancies and the resulting dosimetric impact by a 6-degree-of-freedom couch in combination with daily kilovoltage cone beam computed tomography, Radiation Oncology, 10, 1, 10.1186/s13014-015-0412-x