Reusable urine glucose sensor based on functionalized graphene oxide conjugated Au electrode with protective layers

Biotechnology Reports - Tập 3 - Trang 49-53 - 2014
Hye Youn Kim1, Kuk Jin Jang1, Murugan Veerapandian2, Hyung Chul Kim3, Yeong Tai Seo1, Kook Nyung Lee1, Min-Ho Lee1
1Korea Electronics Technology Institute, 68 Yatap-dong, Bundang-gu, Seongnam, Gyeonggi Do 463-816, South Korea
2Department of Chemistry, University of Montreal, 2900 Edouard Montpetit, Montreal, Quebec H3T 1J4, Canada
3Department of Environmental & Health Chemistry, College of Pharmacy, Chung-Ang University, Dongjak-Ku, Seoul 156-756, South Korea

Tài liệu tham khảo

Amaral, 2008, Current development in non-invasive glucose monitoring, Med. Eng. Phys., 30, 541, 10.1016/j.medengphy.2007.06.003 Cai, 2004, Direct electron transfer of glucose oxidase promoted by carbon nanotubes, Anal. Biochem., 332, 75, 10.1016/j.ab.2004.05.057 Jean, 2008 Kausaite-Minkstimiene, 2011, Evaluation of amperometric glucose biosensors based on glucose oxidase encapsulated within enzymatically synthesized polyaniline and polypyrrole, Sens. Actuators B: Chem., 158, 278, 10.1016/j.snb.2011.06.019 Liu, 2005, The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix, Biosens. Bioelectron., 21, 984, 10.1016/j.bios.2005.03.003 Matsumoto, 1998, A micro-planar amperometric glucose sensor unsusceptible to interference species, Sens. Actuators B: Chem., 49, 68, 10.1016/S0925-4005(98)00145-2 Matsumoto, 2001, A long-term lifetime amperometric glucose sensor with a perfluorocarbon polymer coating, Biosens. Bioelectron., 16, 271, 10.1016/S0956-5663(01)00139-7 Mazeiko, 2013, Gold nanoparticle and conducting polymer-polyaniline-based nanocomposites for glucose biosensor design, Sens. Actuators B: Chem., 189, 187, 10.1016/j.snb.2013.03.140 Miyashita, 2009, Development of urine glucose meter based on micro-planar amperometric biosensor and its clinical application for self-monitoring of urine glucose, Biosens. Bioelectron., 24, 1336, 10.1016/j.bios.2008.07.072 Okahata, 1989, Preparation of Langmuir–Blodgett films of enzyme-lipid complexes: a glucose sensor membrane, Thin Solid Films, 180, 65, 10.1016/0040-6090(89)90055-2 Shan, 2009, Direct electrochemistry of glucose oxidase and biosensing for glucose based on graphene, Anal. Chem., 81, 2378, 10.1021/ac802193c Song, 2010, Graphene oxide: intrinsic peroxidase catalytic activity and its application to glucose detection, Adv. Mater., 22, 2206, 10.1002/adma.200903783 Veerapandian, 2014, Metalloid polymer nanoparticle functionalized graphene oxide working electrode for durable glucose sensing, Mater. Res. Bull., 49, 593, 10.1016/j.materresbull.2013.09.045 Wang, 2011, Enhanced direct electrochemistry of glucose oxidase and biosensing for glucose via synergy effect of graphene and CdS nanocrystals, Biosens. Bioelectron., 26, 2252, 10.1016/j.bios.2010.09.043 Wang, 2004, Direct electron transfer between cytochrome c and a gold nanoparticles modified electrode, Electrochem. Commun., 6, 49, 10.1016/j.elecom.2003.10.004 Wu, 2013, α-Nickel hydroxide 3D hierarchical architectures: controlled synthesis and their applications on electrochemical determination of H2O2, Mater. Res. Bull., 48, 2340, 10.1016/j.materresbull.2013.02.080 Yao, 1983, A chemically-modified enzyme membrane electrode as an amperometric glucose sensor, Anal. Chim. Acta, 148, 27, 10.1016/S0003-2670(00)85149-1 Zeng, 2012, Nickel nano particle modified nitrogen-doped amorphous hydrogenated diamond-like carbon film for glucose sensing, Mater. Res. Bull., 47, 2713, 10.1016/j.materresbull.2012.04.041