Replicating proximal humeral articular geometry with a third-generation implant: A radiographic study in cadaveric shoulders

Journal of Shoulder and Elbow Surgery - Tập 16 - Trang S111-S116 - 2007
Michael A. Wirth1, Jeff Ondrla2, Carleton Southworth3, Ken Kaar4, Brett C. Anderson1, Charles A. Rockwood1
1Department of Orthopaedics, University of Texas Health Science Center at San Antonio, San Antonio, TX
2DVO Extremity Solutions, Warsaw, IN
3DePuy Orthopaedics, Warsaw, IN
4Merlin Park Regional Hospital, Galway, Ireland.

Tài liệu tham khảo

Ballmer, 1993, Humeral head prosthetic arthroplasty: surgically relevant geometric considerations, J Shoulder Elbow Surg, 2, 296, 10.1016/1058-2746(93)90075-R Boileau, 1997, The three-dimensional geometry of the proximal humerus: implications for surgical technique and prosthetic design, J Bone Joint Surg Br, 79, 857, 10.1302/0301-620X.79B5.7579 Harryman, 1995, The effect of articular conformity and the size of the humeral head component on laxity and motion after glenohumeral arthroplasty, J Bone Joint Surg Am, 77, 555, 10.2106/00004623-199504000-00008 Hertel, 2002, Geometry of the proximal humerus and implications for prosthetic design, J Shoulder Elbow Surg, 11, 331, 10.1067/mse.2002.124429 Iannotti, 1992, The normal glenohumeral relationships: an anatomical study of one hundred and forty shoulders, J Bone Joint Surg Am, 74, 491, 10.2106/00004623-199274040-00004 Karduna, 1997, Joint stability after total shoulder arthroplasty in a cadaver model, J Shoulder Elbow Surg, 6, 506, 10.1016/S1058-2746(97)90082-3 McPherson, 1997, Anthropometric study of normal glenohumeral relationships, J Shoulder Elbow Surg, 6, 105, 10.1016/S1058-2746(97)90030-6 Pearl, 2005, Proximal humeral anatomy in shoulder arthroplasty: implications for prosthetic design and surgical technique, J Shoulder Elbow Surg, 14, 99S, 10.1016/j.jse.2004.09.025 Pearl, 1999, Geometric analysis of commonly used prosthetic systems for proximal humeral replacement, J Bone Joint Surg Am, 81, 660, 10.2106/00004623-199905000-00007 Pearl, 2002, Geometric analysis of selected press fit prosthetic systems for proximal humeral replacement, J Orthop Res, 20, 192, 10.1016/S0736-0266(01)00111-5 Pearl, 1995, Retroversion of the proximal humerus in relationship to prosthetic replacement arthroplasty, J Shoulder Elbow Surg, 4, 286, 10.1016/S1058-2746(05)80022-9 Walch, 1992, Morphological study of the humeral proximal epiphysis, J Bone Joint Surg Br, 74, 14 Williams, 2001, The effect of articular malposition after total shoulder arthroplasty on glenohumeral translations, range of motion, and subacromial impingement, J Shoulder Elbow Surg, 10, 399, 10.1067/mse.2001.116871