Remote heart rate measurement using low-cost RGB face video: a technical literature review

Springer Science and Business Media LLC - Tập 12 Số 5 - Trang 858-872 - 2018
Philipp V. Rouast1, Marc T. P. Adam2, Raymond Chiong2, David Cornforth2, Ewa Lux1
1Institute of Information Systems and Marketing, Karlsruhe Institute of Technology, Karlsruhe, Germany
2School of Electrical Engineering and Computing, The University of Newcastle, Callaghan, Australia

Tóm tắt

Từ khóa


Tài liệu tham khảo

Zhang Z L, Pi Z Y, Liu B Y. Troika: a general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise. IEEE Transactions on Biomedical Engineering, 2015, 62(2): 522–531

Adam M T P, Krämer J, Weinhardt C. Excitement up! Price down! Measuring emotions in dutch auctions. International Journal of Electronic Commerce, 2012, 13(2): 7–39

Adam M T P, Krämer J, Müller MB. Auction fever! How time pressure and social competition affect bidders’ arousal and bids in retail auctions. Journal of Retailing, 2015, 91(3): 468–485

Astor P J, Adam M T P, Jerčić P, Schaaff K, Weinhardt C. Integrating biosignals into information systems: a neurois tool for improving emotion regulation. Journal of Management Information Systems, 2013, 30(3): 247–278

Riedl R. On the biology of technostress: literature review and research agenda. ACM SIGMIS Database, 2013, 44(1): 18–55

Verkruysse W, Svaasand LO, Nelson JS. Remote plethysmographic imaging using ambient light. Optics Express, 2008, 16(26): 21434–21445

McDuff D J, Estepp J R, Piasecki A M, Blackford E B. A survey of remote optical photoplethysmographic imaging methods. In: Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2015, 6398–6404

Liu H, Wang Y D, Wang L. A review of non-contact, low-cost physiological information measurement based on photoplethysmographic imaging. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2012, 2088–2091

Kranjec J, Beguš S, Geršak G, Drnovšek J. Non-contact heart rate and heart rate variability measurements: a review. Biomedical Signal Processing and Control, 2014, 13(1): 102–112

Poh M-Z, McDuff D J, Picard R W. Non-contact, automated cardiac pulse measurements using video imaging and blind source separation. Optics Express, 2010, 18(10): 10762–10774

Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement, 2007, 28(3): R1–R39

Lindberg L-G, Öberg P A. Optical properties of blood in motion. Optical Engineering, 1993, 32(2): 253–257

Balakrishnan G, Durand F, Guttag J. Detecting pulse from head motions in video. In: Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition. 2013, 3430–3437

Starr I, Rawson A J, Schroeder H A, Joseph N R. Studies on the estimation of cardiac ouptut in man, and of abnormalities in cardiac function, from the heart’s recoil and the blood’s impacts; the ballistocardiogram. American Journal of Physiology, 1939, 127(1): 1–28

Hertzman A B, Spealman C R. Observations on the finger volume pulse recorded photoelectrically. American Journal of Physiology, 1937, 119(2): 334–335

Poh M-Z, McDuff D J, Picard RW. Advancements in noncontact, multiparameter physiological measurements using a webcam. IEEE Transactions on Biomedical Engineering, 2011, 58(1): 7–11

Lewandowska M, Ruminski J, Kocejko T. Measuring pulse rate with a webcam: a non-contact method for evaluating cardiac activity. In: Proceedings of the Federated Conference on Computer Science and Information Systems (FedCSIS). 2011, 405–410

Kwon S, Kim H, Park K S. Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2012, 2174–2177

Lee K-Z, Hung P-C, Tsai L-W. Contact-free heart rate measurement using a camera. In: Proceedings of the 9th Conference on Computer and Robot Vision. 2012, 147–152

Wei L, Tian Y H, Wang Y W, Ebrahimi T, Huang T. Automatic webcam-based human heart rate measurements using laplacian eigenmap. In: Proceedings of Asian Conference on Computer Vision. 2013, 281–292

Wu H-Y, Rubinstein M, Shih E, Guttag J V, Durand F, Freeman W T. Eulerian video magnification for revealing subtle changes in the world. ACM Transactions on Graphics, 2012, 31(4): 1–8

Wu H-Y. Eulerian video processing and medical applications. Dissertation for the Master Degree. Cambridge, MA: Massachusetts Institute of Technology, 2012

Shan L, Yu M H. Video-based heart rate measurement using head motion tracking and ica. In: Proceedings of the 6th International Congress on Image and Signal Processing. 2013, 160–164

Irani R, Nasrollahi K, Moeslund T B. Improved pulse detection from head motions using dct. In: Proceedings of the 9th International Conference on Computer Vision Theory and Applications. 2014, 118–124

De Haan G, Jeanne V. Robust pulse rate from chrominance-based rPPG. IEEE Transactions on Biomedical Engineering, 2013, 60(10): 2878–2886

De Haan G, Van Leest A. Improved motion robustness of remote-PPG by using the blood volume pulse signature. Physiological Measurement, 2014, 35(9): 1913–1926

Lempe G, Zaunseder S, Wirthgen T, Zipser S, Malberg H. ROI selection for remote photoplethysmography. In: Meinzer H-P, Deserno MT, Handels H, et al, eds. Bildverarbeitung für die Medizin 2013. Berlin: Springer, 2013, 99–103

Datcu D, Cidota M, Lukosch S, Rothkrantz L. Noncontact automatic heart rate analysis in visible spectrum by specific face regions. In: Proceedings of the 14th International Conference on Computer Systems and Technologies. 2013, 120–127

Li X B, Chen J, Zhao G Y, Pietikäinen M. Remote heart rate measurement from face videos under realistic situations. In: Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition. 2014, 4264–4271

McDuff D, Gontarek S, Picard RW. Remote detection of photoplethysmographic systolic and diastolic peaks using a digital camera. IEEE Transactions on Biomedical Engineering, 2014, 61(12): 2948–2954

Kumar M, Veeraraghavan A, Sabharwal A. DistancePPG: robust noncontact vital signs monitoring using a camera. Biomedical Optics Express, 2015, 6(5): 1565–1588

Tasli H E, Gudi A, Den Uyl M. Remote PPG based vital sign measurement using adaptive facial regions. In: Proceedings of IEEE International Conference on Image Processing. 2014, 1410–1414

Feng L T, Po L-M, Xu X Y, Li Y M. Motion artifacts suppression for remote imaging photoplethysmography. In: Proceedings of the 19th International Conference on Digital Signal Processing. 2014, 18–23

Feng L T, Po L-M, Xu X Y, Li Y M, Ma R Y. Motion-resistant remote imaging photoplethysmography based on the optical properties of skin. IEEE Transactions on Circuits and Systems for Video Technology, 2015, 25(5): 879–891

Wang W J, Stuijk S, De Haan G. Exploiting spatial redundancy of image sensor for motion robust rPPG. IEEE Transactions on Biomedical Engineering, 2015, 62(2): 415–425

McDuff D, Gontarek S, Picard R W. Improvements in remote cardiopulmonary measurement using a five band digital camera. IEEE Transactions on Biomedical Engineering, 2014, 61(10): 2593–2601

Chwyl B, Chung A G, Deglint J, Wong A, Clausi D A. Remote heart rate measurement through broadband video via stochastic bayesian estimation. Vision Letters, 2015, 1(1): 5

Monkaresi H, Calvo R A, Yan H. A machine learning approach to improve contactless heart rate monitoring using a webcam. IEEE Journal of Biomedical and Health Informatics, 2014, 18(4): 1153–1160

Hsu Y, Lin Y L, Hsu W. Learning-based heart rate detection from remote photoplethysmography features. In: Proceedings of IEEE International Conference on Acoustics, Speech and Signal Processing. 2014, 4433–4437

Tran D N, Lee H, Kim C. A robust real time system for remote heart rate measurement via a camera. In: Proceedings of IEEE International Conference on Multimedia and Expo. 2015, 1–6

Li M-C, Lin Y-H. A real-time non-contact pulse rate detector based on smartphone. In: Proceedings of International Symposium on Next-Generation Electronics. 2015, 1–3

Yu Y-P, Kwan B-H, Lim C-L, Wong S-L, Raveendran P. Video-based heart rate measurement using short-time fourier transform. In: Proceedings of International Symposium on Intelligent Signal Processing and Communication Systems. 2013, 704–707

Holton B D, Mannapperuma K, Lesniewski P J, Thomas J C. Signal recovery in imaging photoplethysmography. Physiological Measurement, 2013, 34(11): 1499–1511

Xu S C, Sun L Y, Rohde G K. Robust efficient estimation of heart rate pulse from video. Biomedical Optics Express, 2014, 5(4): 1124–1135

Feng L T, Po L-M, Xu X Y, Li Y M, Cheung C-H, Cheung K-W, Yuan F. Dynamic ROI based on K-means for remote photoplethysmography. In: Proceedings of IEEE International Conference on Acoustics, Speech and Signal Processing. 2015, 1310–1314

Han B, Ivanov K, Wang L, Yan Y. Exploration of the optimal skincamera distance for facial photoplethysmographic imaging measurement using cameras of different types. In: Proceedings of the 5th EAI International Conference onWireless Mobile Communication and Healthcare. 2015, 186–189

Zhang K H, Zhang L, Yang M-H. Real-time compressive tracking. In: Proceedings of European Conference on Computer Vision. 2012, 864–877

Fernández A, Carúz J L, Usamentiaga R, Alvarez E, Casado R. Unobtrusive health monitoring system using video-based physiological information and activity measurements. In: Proceedings of International Conference on Computer, Information and Telecommunication Systems. 2012, 1–5

Danelljan M, Häger G, Felsberg M. Accurate scale estimation for robust visual tracking. In: Proceedings of the British Machine Vision Conference. 2014, 1–10

Hoffmann K-P. Biosignale erfassen und verarbeiten. In: Kramme R, ed. Medizintechnik. Berlin: Springer, 2011, 667–688

Viola P, Jones M. Rapid object detection using a boosted cascade of simple features. In: Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition. 2001, 511–518

Cootes T F, Edwards G J, Taylor C J. Active appearance models. In: Proceedings of European Conference on Computer Vision. 1998, 484–498

Asthana A, Zafeiriou S, Cheng S Y, Pantic M. Robust discriminative response map fitting with constrained local models. In: Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition. 2013, 3444–3451

Saragih J M, Lucey S, Cohn J F. Deformable model fitting by regularized landmark mean-shift. International Journal of Computer Vision, 2011, 91(2): 200–215

Martinez B, Valstar M F, Binefa X, Pantic M. Local evidence aggregation for regression-based facial point detection. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2013, 35(5): 1149–1163

Shi J B, Tomasi C. Good features to track. In: Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition. 1994, 593–600

Lucas B D, Kanade T. An iterative image registration technique with an application to stereo vision. In: Proceedings of the 7th International Joint Conference on Artificial Intelligence. 1981, 674–679

Bay H, Tuytelaars T, Van Gool L. SURF: speeded up robust features. In: Proceedings of European Conference on Computer Vision. 2006, 404–417

Comaniciu D, Ramesh V, Meer P. Kernel-based object tracking. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2003, 25(5): 564–577

Henriques J F, Caseiro R, Martins P, Batista J. Exploiting the circulant structure of tracking-by-detection with kernels. In: Proceedings of European Conference on Computer Vision. 2012, 702–715

Farnebäck G. Two-frame motion estimation based on polynomial expansion. In: Proceedings of Scandinavian Conference on Image Analysis. 2003, 363–370

Tarvainen M P, Ranta-Aho P O, Karjalainen P A. An advanced detrending method with application to hrv analysis. IEEE Transactions on Biomedical Engineering, 2002, 49(2): 172–175

Rouast P V, Adam M T P, Cornforth D J, Lux E, Weinhardt C. Using contactless heart rate measurements for real-time assessment of affective states. In: Davis F D, Riedl R, Vom Brocke J, et al, eds. Information Systems and Neuroscience. Springer International Publishing, 2016, 157–163

Monkaresi H, Hussain M S, Calvo R A. Using remote heart rate measurement for affect detection. In: Proceedings of the 27th International Florida Artificial Intelligence Research Society Conference. 2014, 118–123

Zhao F, Li M, Qian Y, Tsien J Z. Remote measurements of heart and respiration rates for telemedicine. PLoS ONE, 2013, 8(10): e71384

McDuff D, Gontarek S, Picard R. Remote measurement of cognitive stress via heart rate variability. In: Proceedings of the 36th IEEE Annual International Conference of Engineering in Medicine and Biology Society. 2014, 2957–2960

Rahman M A, Barai A, Islam M A, Hashem M M A. Development of a device for remote monitoring of heart rate and body temperature. In: Proceedings of the 15th International Conference on Computer and Information Technology. 2012, 411–416