Reliability Impact Analysis of Fault Current Limiters of Distribution Network Under Protection Miscoordination Due to Distributed Generations
Tóm tắt
Despite distributed generations (DGs) advantages, the presence of them can cause glitches in distribution networks. One of the typical glitches is a mismatched fuse and recloser in temporary short circuits, which is often remedied by fault current limiter (FCL). By calculating the expected benefits to distribution companies (DISCOs) in various value of loss load scenarios, once the uncertainty output of DGs is considered, this paper examines the effectiveness of FCLs in solving drawbacks and improving reliability. FCL can improve network reliability in one of two ways: a) the FCL can reduce the magnitude of fault current, thereby decreasing the failure rate of protective devices, b) the FCL can correct a mismatched fuse and recloser, resulting in a lower energy not supplied (ENS) rate. The present paper uses the biogeography-based optimization method to measure optimal FCL impedance in terms of maximizing the DISCO’s benefit after FCL installation. Using simulated performance on a test distribution system, FCL network penetration is founded to resolve the identified problem by improving the ENS rate.
Tài liệu tham khảo
Abdolkarimzadeh M, Nazari-Heris M, Abapour M, Sabahi M (2017) A bridge type fault current limiter for energy management of ac/dc microgrids. IEEE Trans Power Electr. https://doi.org/10.1109/TPEL.2017.2655106
Alaraifi S, El Moursi M, Zeineldin H (2013) Optimal allocation of HTS-FCL for power system security and stability enhancement. IEEE Trans Power Syst 28(4):4701–4711
Alvarez-Herranz A, Balsalobre-Lorente D, Shahbaz M, Cantos JM (2017) Energy innovation and renewable energy consumption in the correction of air pollution levels. Energy Policy 105:386–397
Chen M-T, Nguyen C-H (2015) Voltage quality performance improvement of a distribution feeder with superconducting fault current limiter. Int J Electr Eng Inf 7(1):102
Chen L, Zhang X, Chen H, Li G, Yang J, Tian X, Xu Y, Ren L, Tang Y (2019) Pareto optimal allocation of resistive-type fault current limiters in active distribution networks with inverter-interfaced and synchronous distributed generators. Energy Sci Eng 7(6):2554–2571
Chen B, Wei L, Lei Y, Zhong Y, Tian C, Guan W, Gao Y, Muramatsu K, Yuan J (2016) Investigation on a modified hybrid compact saturated-core fault current limiter based on permanent magnets. In: Electromagnetic Field Computation (CEFC), 2016 IEEE Conference on, IEEE, pp 1–1
Ebrahimi E, Sanjari MJ, Gharehpetian GB (2014) Control of three-phase inverter-based dg system during fault condition without changing protection coordination. Int J Electr Power Energy Syst 63:814–823
Elmitwally A, Gouda E, Eladawy S (2015) Optimal allocation of fault current limiters for sustaining overcurrent relays coordination in a power system with distributed generation. Alex Eng J 54(4):1077–1089
Elmitwally A, Gouda E, Eladawy S (2016) Restoring recloser-fuse coordination by optimal fault current limiters planning in dg-integrated distribution systems. Int J Electr Power Energy Syst 77:9–18
Firouzi M, Gharehpetian G, Pishvaei M (2013) A dual-functional bridge type fcl to restore pcc voltage. Int J Electr Power Energy Syst 46:49–55
Haghifam MR, Ghaderi A, Abapour M (2009) Enhancement circuit breaker reliability by using fault current limiter. In: Power and energy society general meeting, PES’09. IEEE, 2009, pp 1–5
Hashemi Y, Valipour K (2014) Fdm based multi-objective optimal sitting and design of tc-flsfcl for study of distribution system reliability. Int J Electr Power Energy Syst 61:463–473
Heydt GT, Graf TJ (2010) Distribution system reliability evaluation using enhanced samples in a monte carlo approach. IEEE Trans power Syst 25(4):2006–2008
Huchel L, Zeineldin H, El-Saadany E (2016) Protection coordination index enhancement considering multiple DG locations using FCL. IEEE Trans Power Deliv 32(1):344–350
Ibrahim DK, El Zahab EEDA, Mostafa SAEA (2017) New coordination approach to minimize the number of re-adjusted relays when adding DGs in interconnected power systems with a minimum value of fault current limiter. Int J Electr Power Energy Syst 85:32–41
Jafari M, Naderi S, Hagh MT, Abapour M, Hosseini S (2011) Voltage sag compensation of point of common coupling (pcc) using fault current limiter. IEEE Trans Power Deliv 26(4):2638–2646
Javadi H, Mousavi SA, Khederzadeh M (2013) A novel approach to increase FCL application in preservation of over-current relays coordination in presence of asynchronous DGs. Int J Electr Power Energy Syst 44(1):810–815
Kim S-Y, Kim W-W, Kim J-O (2011) Evaluation of distribution reliability with superconducting fault current limiter. In: 2011 10th International conference on environment and electrical engineering, IEEE, pp 1–5
Kim S-Y, Kim J-O (2011) Reliability evaluation of distribution network with DG considering the reliability of protective devices affected by SFCL. IEEE Trans Appl supercond 21(5):3561–3569
Kim J-H, Lee J, Joo S-K (2015) Conditional value-at-risk-based method for evaluating the economic risk of superconducting fault current limiter installation. IEEE Trans Appl Supercond 25(3):1–4
Mahmoudian A, Niasati M, Khanesar MA (2017) Multi objective optimal allocation of fault current limiters in power system. Int J Electr Power Energy Syst 85:1–11
Naiem A, Hegazy Y, Abdelaziz A, Elsharkawy M (2012) A classification technique for recloser-fuse coordination in distribution systems with distributed generation. IEEE Trans Power Deliv 27(1):176–185
Nazari-Heris M, Nourmohamadi H, Abapour M, Sabahi M (2017) Multilevel nonsuperconducting fault current limiter: analysis and practical feasibility. IEEE Trans Power Electr 32(8):6059–6068
Nourmohamadi H, Nazari-Heris M, Sabahi M, Abapour M (2018) A novel structure for bridge-type fault current limiter: capacitor based nonsuperconducting FCL. IEEE Trans Power Electron 33(4):3044–3051
Rezaei N, Haghifam M-R (2008) Protection scheme for a distribution system with distributed generation using neural networks. Int J Electr Power Energy Syst 30(4):235–241
Schacherer C, Bauer A, Elschner S, Goldacker W, Kraemer H-P, Kudymow A, Nackel O, Strauss S, Zermeno VM (2016) Smartcoil-concept of a full scale demonstrator of a shielded core type superconducting fault current limiter. IEEE Trans Appl Supercond. https://doi.org/10.1109/TASC.2016.2642139
Seo H-C, Kim C-H, Rhee S-B, Kim J-C, Hyun O-B (2010) Superconducting fault current limiter application for reduction of the transformer inrush current: a decision scheme of the optimal insertion resistance. IEEE Trans Appl Supercond 20(4):2255–2264
Simon D (2008) Biogeography-based optimization. IEEE Trans Evolut Comput 12(6):702–713
Tseng H-T, Chen J-F (2014) Quasi-bridge-type fault current limiter for mitigating fault transient phenomena. IET Gener Transm Distr 8(8):1377–1391
Wang M, Gooi H, Chen S (2011) Optimising probabilistic spinning reserve using an analytical expected-energy-not-supplied formulation. IET Gener Transm Distrib 5(7):772–780
Yu P, Venkatesh B, Yazdani A, Singh BN (2016) Optimal location and sizing of fault current limiters in mesh networks using iterative mixed integer nonlinear programming. IEEE Trans Power Syst 31(6):4776–4783
Zeineldin HH, Mohamed YA-RI, Khadkikar V, Pandi VR (2013) A protection coordination index for evaluating distributed generation impacts on protection for meshed distribution systems. IEEE Trans Smart Grid 4(3):1523–1532