Relationship Between Catheter Stability and 12-Month Success After Pulmonary Vein Isolation

JACC: Clinical Electrophysiology - Tập 2 - Trang 691-699 - 2016
Vivek Y. Reddy1, Scott Pollak2, Bruce D. Lindsay3, H. Thomas McElderry4, Andrea Natale5, Charan Kantipudi6, Moussa Mansour7, Daniel P. Melby8, Dhanunjaya Lakkireddy9, Tzachi Levy10, David Izraeli11, Chithra Sangli11, David Wilber12
1Icahn School of Medicine at Mount Sinai, New York, New York, USA
2Florida Hospital, Cardiovascular Research, Orlando, Florida, USA
3Cleveland Clinic Foundation, Cleveland, Ohio USA
4University of Alabama, Birmingham, Alabama USA;
5Texas Cardiac Arrhythmia Research Foundation, Austin, Texas, USA
6Piedmont Heart Institute, Atlanta, Georgia, USA
7Massachusetts General Hospital, Cardiac Arrhythmia Center, Boston, Massachusetts, USA
8Abbott Northwestern Hospital, Minneapolis, Minnesota, USA
9University of Kansas, Mid-America Cardiology, Kansas City, Kansas, USA
10Biosense Webster (Israel), Ltd, Yokneam, Israel
11Biosense Webster Inc., Diamond Bar, California, USA
12Loyola University Medical Center, Maywood, Illinois, USA.

Tài liệu tham khảo

Stabile, 2006, Catheter ablation treatment in patients with drug-refractory atrial fibrillation: a prospective, multi-centre, randomized, controlled study (Catheter Ablation For The Cure Of Atrial Fibrillation Study), Eur Heart J, 27, 216, 10.1093/eurheartj/ehi583 Calkins, 2012, 2012 HRS/EHRA/ECAS Expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design, Europace, 14, 528, 10.1093/europace/eus027 Jaïs, 2008, Catheter ablation versus antiarrhythmic drugs for atrial fibrillation: the A4 study, Circulation, 118, 2498, 10.1161/CIRCULATIONAHA.108.772582 Natale, 2014, Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial, J Am Coll Cardiol, 64, 647, 10.1016/j.jacc.2014.04.072 Avitall, 1997, The effects of electrode-tissue contact on radiofrequency lesion generation, Pacing Clin Electrophysiol, 20, 2899, 10.1111/j.1540-8159.1997.tb05458.x Okumura, 2008, A systematical analysis of in vivo contact forces on virtual catheter tip/tissue surface contact during cardiac mapping and intervention, J Cardiovasc Electrophysiol, 19, 632, 10.1111/j.1540-8167.2008.01135.x Williams, 2015, The effect of contact force in atrial radiofrequency ablation: electroanatomical, cardiovascular magnetic resonance, and histological assessment in a chronic porcine model, J Am Coll Cardiol EP, 1, 421 Ouyang, 2005, Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double lasso technique, Circulation, 111, 127, 10.1161/01.CIR.0000151289.73085.36 Ouyang, 2010, Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up, Circulation, 122, 2368, 10.1161/CIRCULATIONAHA.110.946806 Reddy, 2012, The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study, Heart Rhythm, 9, 1789, 10.1016/j.hrthm.2012.07.016 Kuck, 2012, A novel radiofrequency ablation catheter using contact force sensing: Toccata study, Heart Rhythm, 9, 18, 10.1016/j.hrthm.2011.08.021 Kautzner, 2015, EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation, Europace, 17, 1229, 10.1093/europace/euv057 Yokoyama, 2008, Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus, Circ Arrhythm Electrophysiol, 1, 354, 10.1161/CIRCEP.108.803650 Thiagalingam, 2010, Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter, J Cardiovascular Electrophysiol, 21, 806 Wittkampf, 2006, RF catheter ablation: lessons on lesions, Pacing Clin Electrophysiol, 29, 1285, 10.1111/j.1540-8159.2006.00533.x Cappato, 2005, Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation, Circulation, 111, 1100, 10.1161/01.CIR.0000157153.30978.67 Khaykin, 2011, Clinical predictors of arrhythmia recurrences following pulmonary vein antrum isolation for atrial fibrillation: predicting arrhythmia recurrence post-PVAI, J Cardiovasc Electrophysiol, 22, 1206, 10.1111/j.1540-8167.2011.02108.x Fürnkranz, 2010, Characterization of conduction recovery after pulmonary vein isolation using the “single big cryoballoon” technique, Heart Rhythm, 7, 184, 10.1016/j.hrthm.2009.10.038 Nakagawa, 2013, Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation, Circ Arrhythm Electrophysiol, 6, 746, 10.1161/CIRCEP.113.978320 Haldar, 2013, Contact force sensing technology identifies sites of inadequate contact and reduces acute pulmonary vein reconnection: a prospective case control study, Int J Cardiol, 168, 1160, 10.1016/j.ijcard.2012.11.072