Quemaduras en cirugía percutánea: complicación temible
Tài liệu tham khảo
Piqué-Vidal, 2005, The effect of temperature elevation during discontinuous us of rotatory burrs in the correlation of hallux valgus, J Bone Joint Surg, 44, 336
Shin, 2006, Bone temperature estimation during orthopaedic round bur milling operations, J Biomech, 39, 33, 10.1016/j.jbiomech.2004.11.004
Eriksson, 1984, The effect of heat on bone regeneration: an experimental study in rabbit using the bone growth chamber, J Oral Maxillofac Surg, 42, 705, 10.1016/0278-2391(84)90417-8
Eriksson, 1984, Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals, Acta Orthop Scand, 55, 62931, 10.3109/17453678408992410
Tehemar, 1999, Factors affecting heat generations during implant site preparation: a review of biologic observations and future considerations, Int J Oral Maxillofac Implants, 14, 127
Berman, 1984, Thermal induced bone necrosis in rabbits. Relation to implant failure in humans, Clin Orhop, 186, 284
Bonfield, 1992, The temperture dependence of the deformation of bone, J Biomech, 25, 11
Eichler, 1972, Influence of temperature on the compact bone substance during drilling, thread cutting and insertion of bone screws, Z Orthop Inhre Grenzgeb, 110, 909
Kitaoka, 1994, Clinical rating systems for the ankle-hind, midfoot, hallux and lesse toes, Foot Ankle Int, 15, 349, 10.1177/107110079401500701
Roukis, 2009, Percutaneous and minimum incision metatarsal osteotomies: a systematic review, J Foot Ankle Surg, 48, 380, 10.1053/j.jfas.2009.01.007
Del Prado, 2004
Bachus, 2000, The effects of drilling force on cortical temperatures and their duration: an in vitro study, Med Eng Phys, 22, 685, 10.1016/S1350-4533(01)00016-9
Shin, 2006, Bone temperature estimation during orthopaedic round bur milling operations, J Biomech, 39, 33, 10.1016/j.jbiomech.2004.11.004
Brisman, 1996, The effect of speed, pressure, and time on bone temperature during the drilling of implant sites, Int J Oral maxillofac Implants, 11, 35
Eriksson, 1982, Thermal injury to bone. A vital-microscopic description of heat effects, Int J Oral Surg, 11, 115, 10.1016/S0300-9785(82)80020-3
Benington, 2002, Thermal changes observed at implant sites during internal and externalirrigation, Clin Oral Implants Res, 13, 293, 10.1034/j.1600-0501.2002.130309.x
Chacon, 2006, Heat production by 3 implant drill systems after repeated drilling and sterilization, J Oral Maxillofac Surg, 64, 265, 10.1016/j.joms.2005.10.011
García, 2004, The influence of the size and condition of the reamers on bone temperature during intramedullary reaming, J Bone Joint Surg Am, 86–A, 994, 10.2106/00004623-200405000-00016
Proff, 2006, Requirements and infection prophylaxis for internally cooled implant drills, Folia Morphol (Warsz), 65, 34
Chalk, 1992, Minimal incision surgery, Foot Ankle, 13, 157, 10.1177/107110079201300308