Quantitative X-ray tomography
Tóm tắt
Từ khóa
Tài liệu tham khảo
Stock S. R. ‘Microcomputed tomography: methodology and applications’, 336; 2009, Boca Raton, FL, CRC Press.
Baruchel J., Buffiere J.Y, Maire E., Merie P. and Peix (eds.) G. ‘X-ray tomography in material science’, 204; 2000, Hermes Paris, France.
Banhart J. ‘Advanced tomographic methods in materials research and engineering’, 490; 2008, OUP Oxford. 2008, Oxford, Oxford University Press.
Sanchez S., Ahlberg P. E., Trinajstic K. M., Mirone A. and Tafforeau P. ‘Three dimensional synchrotron virtual paleohistology: a new insight into the world of fossil bone’,Microsc Microanal., 2012,18, (5), 1095–105.
Bradley R. S., 2010, Developments in X-Ray tomography VII, Proc.SPIE
Goetz K., 1979, Kvantovaya Elektron., 6, 1037
Mokso R., Marone F., Haberthuer D., Schittny J. C., Mikuljan G., Isenegger A. and Stampanoni M. ‘Following dynamic processes by X-ray tomographic microscopy with sub-second temporal resolution’, in ‘10th International Conference on X-Ray Microscopy’, (eds. I. McNulty,et al.), 38–41; 2011. Melville, NY, American Institute of Physics, 2011.
MacDowell A. A., 2012, Developments in X-Ray tomography VIII, Proc.SPIE
Withers P.J. and De Carlo F. ‘Table of CT Imaging Times’, 2013; Available from: https://docs.google.com/spreadsheet/ccc?key = 0Ar8bW1AwveI_dHdTa2VjYndRVl9ybnRPckRrZUQ1alE.
Eastwood D. S., Yufit V., Gelb J., Gu A., Bradley R. S., Harris S. J., Brett D. J. L., Brandon N. P., Lee PD., Withers P. J. and Shearing P. ‘Lithiation induced dilation mapping in a Li-ion battery electrode by 3D X-ray microscopy and digital volume correlation’, Advanced Energy Materials, 2013, in press.
Weiss D., Deffner A. and Kuhn C. ‘Einfluss der Quellbewegung auf Reproduzierbarkeit und Antastabweichung im Röntgen-Computertomographen’, Proc. Fachtagung Industrielle Computertomographie, 2010, Wels. Available online at NDT Database, http://www.ndt.net/article/ctc2010/papers/227.pdf.
Steffen J. and Fröba T. ‘Reducing the focal spot shift of microfocus X-ray tubes to increase the accuracy of CT-based dimensional measurement’, International Symposium on Digital Industrial Radiology and Computed Tomography, 2011, Berlin, Germany.
Rockett P. ‘The development of a laboratory X-ray microtomography system for the study of soft-solids and cellular materials’, PhD thesis, Oxford University, Oxford, 2008.
Deville S., Adrien J., Maire E., Scheel M. and Michiel M. D. i. ‘Time-lapse, three-dimensionalin situimaging of ice crystal growth in a colloidal silica suspension’,Acta Mater., 2013,61, (6), 2077–2086.
Thompson W., Lionheart W. R. B. and Morton E. J. ‘X-ray imaging apparatus of fast cone-beam computed tomography X-ray scanning system, has controller to cause emission of X-rays from source in accordance with firing pattern that causes even distribution of X-rays over virtual cylinder X-ray tomography inspection systems’, patent number US7876879(B2).
Zhang Z.Bieberle M. </author>Barthel F. </author>Szalinski L., and Hampel U. ‘Investigation of upward cocurrent gas-liquid pipe flow using ultrafast X-ray tomography and wire-mesh sensor’,Flow Measurement and Instrumentation, 2013,32, 111–118.
Tkachuk A., 2006, Developments in X-ray Tomography V, Proc.SPIE
W. B. Yun, M. Feser, A. Lyon, F. W. Duewer and Y. X. Wang: ‘Pathways to sub-10 nm X-ray imaging using zone plate lens’, Design and Microfabrication of Novel X-Ray Optics II,Proc. SPIE, 2004, 5539, 133–137.
C. Rau, V. Crecea, C. P. Richter, K. M. Peterson, P. R. Jemian, U. Neuhaeusler, G. Schneider, X. Yu, P. V. Braun, T. C. Chiang and I. K. Robinson: ‘A hard X-ray KB-FZP microscope for tomography with sub-100-nm resolution - art. no. 63181G’, Developments in X-Ray Tomography V, Proc. SPIE, 2006,6318, 63181G, doi:10.1117/12.680975.
Mayo S. C., Miller P. R., Sheffield-Parker J., Gureyev T. and Wilkins S. W. ‘Attainment of<60nm Resolution in Phase-Contrast X-ray Microscopy using an add-on to an SEM’, Proc.8th Int. Conf. X-ray Microscopy IPAP Conf. Series 7, Himeji, Japan, 26–30 July, 343–345, 2005. Tokyo, Japan, IPAP, 2005.
Burnett T. L., Curioni M., Hashimoto T., McDonald S. A., Thompson G. E., Withers P. J., Guerts R., Janus M. and Vilsteren C. V. ‘Correlative Tomography’, in press, 2013.
Liu W. J., 2005, Rev. Sci. Instrum., 76, 10310
Snigirev A., Snigireva I., Grigoriev M., Yunkin V., Di Michiel M., Vaughan G., Kohn V. and Kuznetsov S. ‘High energy X-ray nanofocusing by silicon planar lenses’, in ‘9th International Conference on X-Ray Microscopy’, (eds. C. David,et al.), 2009, Bristol, Iop Publishing Ltd.
Kirz J. and Jacobsen C. ‘The history and future of X-ray microscopy’, in ‘9th International Conference on X-Ray Microscopy’, (eds. C. David,et al.), 2009.
Toda H., 2006, Aluminium alloys 2006, Pts 1 and 2: research through innovation and technology, Mater.Sci. Forum, 519, 1361
Withers P. J., 2012, Adv. Mater. Processes, 170, 28
Hannesson K. and Jensen D. J. ‘Three dimensional characterization of grain structures by EBSP and 3DXRD’,Materials Science Forum, 2007,558-559, 751–756.
West S. S., Winther G., Margulies L., Knudsen E., Sorensen H. O., Schmidt S. and Jensen D. J. ‘Mapping partially recrystallised structures by 3DXRD’,Materials Science Forum, 2007,558-559, 389–394.
Savran V. I., Offerman S. E., van Dijk N. H., Lauridsen E. M., Margulies L. and Sietsma J. ‘Growth of individual austenite grains measured with 3DXRD microscopy’,Materials Science Forum, 2007,561-565, 2301–2304.
Yang Z.G and Enomoto M. ‘Discussion on the nucleation rate of ferrite during continuous cooling in a lowcarbon steel measured by 3DXRD’, in ‘Solid-Solid Phase Transformations in Inorganic Materials ‘05’, edited by Howe et al., 2005, Warrendale, PA, TMS. Pages 47–52.
Hefferan C. M., 2009, CMC Comput. Mater. Continua, 14, 209
Barabash R. I., 2011, J. Met., 63, 30
Gonzalez D., King A., Simonovski I., Quinta da Fonseca J. and Withers P. J. ‘Modelling & measurement of plastic deformation & grain rotation in 3D at the grain to grain level’, 2013, in press.
Kak A. C. and Slaney M. ‘Principles of computerised tomographic imaging’; 1987, IEEE Press. New York.
Van Gompel G. ‘Towards accurate image reconstruction from truncated X-ray CT projections’, PhD thesis, Antwerp University, 2009. Antwerp.
Herman G.T. and Kuba A. (eds). Advances in discrete tomography and its applications, 392; 2007, Birkhäuser, Basel.
Sidky E. Y., 2006, J. Xray Sci. Technol., 14, 119
Zhou J., Bousse A., Yang G. and Bellanger J.J. ‘A blob-based tomographic reconstruction of 3D coronary trees from rotational X-ray angiography’, Medical Imaging 2008: Physics of Medical Imaging,Proc. SPIE, 2008,6913, 69132N, doi:10.1117/12.769478.
Hsieh J., Nett B., Yu Z., Sauer K., Thibault J.B and Bouman C. A. ‘Recent advances in CT image reconstruction’,Current Radiology Reports, 2013,1, (1), 39–51.
Yu H., Xu Q., Mou X. and Wang G. ‘Recent progress in local reconstruction’, Developments in X-ray tomography VII, Proc.SPIE, 2010, 7804, 78040V, doi:10.1117/12.859772.
Siewert T. A., 1992, Mater. Eval., 50, 1027-1032
Krueger P., Niese S., Zschech E., Gelb J. and Feser M. ‘Improved scanning geometry to collect 3D-geometry data iun flat samples’, 10th Conf on ‘X-ray Microscopy’, 258–260; 2011, Chicago. 2010, Melville, NY, American Institute of Physics.
Rasband W.S. ‘ImageJ,’1997—2012; Available from: imagej.nih.gov.
Carmignato S., Pierobon A., Rampazzo P., Parisatto M. and Savio E. ‘CT for industrial metrology - accuracy and strictural resolution of CT dimensional measurements’, Conf Industrial Computed Tomography (ICT), 161–172; 2012, Aachen.
Leonard F., Brown S. B., Mummery P. M., McCarthy M. B. and Withers P. J. ‘Accuracy and repeatability of X-ray computed tomography measurements’, Sub Measurement Sci. Tech., 2013.
Badel P., Maire E., Vidal-Salle E. and Boisse P. ‘Mesoscopic Mechanical Analyses of Textile Composites: Validation with X-Ray Tomography’, in ‘Mechanics of Microstructured Solids 2: Cellular Materials, Fibre Reinforced Solids and Soft Tissues: Cellular Materials, Fibre Reinforced Solids and Soft Tissues’, (eds. J. F. Ganghoffer,et al.), 71–78; 2010. Berlin, Springer Verlag.
Withers P. J., 2012, Ingenia, 51, 40
Smith T. S. and Bay B. K. ‘Experimental measurement of strains using digital volume correlation’, in ‘Nontraditional methods of sensing stress, strain and damage in materials and structures: second volume’, (eds. G. F. Lucas,et al.), 117–126; 2001. 2001, West Conshohocken, PA: ASTM International.
Bornert M., 2004, Instrum. Mes. Metrol., 88, 49
Ignatiev K. I., Lee W. K., Fezzaa K., De Carlo F. and Stock S. R. ‘Phase contrast stereometry: Fatigue crack mapping in 3D’, Developments in X-ray tomography IV,Proc. SPIE, 2004,5535, 253–260.
Stock S. R., Ignatiev K., Davis G. R., Elliott J. C., Fezzaa K. and Lee W.K. ‘Fatigue cracks in Aluminum samples studied with X-ray phase contrast imaging and with absorption microstomography’, in ‘Advances in X-ray Analysis’, 123–127; 2002, New York, JCPDS-International Centre for Diffraction Data.
Mostafavi M., McDonald S. A. Çetinel H., Mummery P. M. and Marrow T. J. ‘Flexural strength and defect behaviour in a quasi-brittle material (polygranular graphite) under different states of stress ‘,Carbon, 2013, In press.
Mostafavi M., McDonald S. A., Mummery P. M. and Marrow T. J. ‘Observation and quantification of three-dimensional crack propagation in poly-granular graphite’,Engineering Fracture Mechanics,Available online 12 January 2013, ISSN 0013-7944, http:///dx.doi.org/10.1016/j.engfracmech.2012.11.023. (http://www.sciencedirect.com/science/article/pii/S0013794413000052).
Buffiere J.Y, Limodin N., Rethore J., Ludwig W., Hild F., Gravouil A. and Roux S. ‘3D Characterisation of fatigue cracks using X-ray tomography from synchrotron to laboratory sources’, in ‘139th Annual Meeting & Exhibition - Supplemental Proceedings, Vol 2: Materials Characterization, Computation and Modeling and Energy’, 705–712; 2010, TMS. Warrendale, PA.
Marrow T. J., Babout L., Connolly B. J., Engelberg D., Johnson G., Buffiere J.Y, Withers P. J. and Newman R. C. ‘High-resolution,in situ, tomographic observations of stress corrosion cracking’, in ‘Environment-induced cracking of metals, volume 2: Prediction, industrial developments and evaluation’, edited by S. A. Shipilov et al., 2008, Amsterdam, Elsevier, pages 439–447.
G. E. Thompson, T. Hashimoto, X. L. Zhong, M. Curioni, X. Zhou, P. Skeldon, P. J. Withers, J. A. Carr and A. G. Monteith: ‘Revealing the three dimensional internal structure of aluminium alloys’, Surf. Interface Anal., 2013, doi: 10.1002/sia.5221.
King A., 2011, Rev. Metall. Cah. D Inf. Tech., 108, 47
Moulinec H., 1994, C.R. Acad. Sci. Paris II, 318, 1417
You Z. P., 2010, Road Mater. Pavement Des., 11, 273
Bernard D., Salvo L. and Nielsen O. ‘Permeability calculations on real Al-Cu microstructures assessed by 3D microtomography’, Chapter is from - ‘Modeling of Casting, Welding, and Advanced Solidification Processes X’, edited by Doru Stefanescu, James Warren, Mark Jolly, and Matthew Krane, 750 pages, 2003, Warrendale, PA, TMS,175–182; 2003.
Plougonven E., Bernard D. and Combaret N. ‘On pore space partitioning in relation to network model building for fluid flow computation in porous media’, in ‘Advances in computed tomography for geomaterials’, 320–327; 2010, John Wiley & Sons, Inc. Hoboken, NJ, USA.
Ferrie E., 2008, Mater. Struct. Micromech. Fract. V, 567, 301
Wang L., 2011, Mater. Sci. Eng. A Struct. Mater., 42, 626
Simonovski I., Cizelj L., Marrow T. J., da Fonseca J. Q. and King A. ‘Towards modelling intergranular stress-corrosion cracks using experimentally obtained grain topologies’, in ‘Asme Pressure Vessels and Piping Conference 2009, Vol. 3: Design and Analysis’, 543–550; 2009. New York, ASME.