Quantitative Risk Estimation for a <i>Legionella pneumophila</i> Infection Due to Whirlpool Use

Risk Analysis - Tập 33 Số 7 - Trang 1228-1236 - 2013
Martijn Bouwknegt1, Jack Schijven2, J.A.C. Schalk1, Ana Maria de Roda Husman1
1Laboratory for Zoonoses and Environmental Microbiology, Centre for Infectious Disease Control Netherlands, National Institute for Public Health and the Environment, Bilthoven, The Netherlands
2Expert Centre for Methodology and Information Services, National Institute for Public Health and the Environment, Bilthoven, The Netherlands

Tóm tắt

Quantitative microbiological risk assessment was used to quantify the risk associated with the exposure to Legionella pneumophila in a whirlpool. Conceptually, air bubbles ascend to the surface, intercepting Legionella from the traversed water. At the surface the bubble bursts into dominantly noninhalable jet drops and inhalable film drops. Assuming that film drops carry half of the intercepted Legionella, a total of four (95% interval: 1–9) and 4.5×104 (4.4×104 – 4.7×104) cfu/min were estimated to be aerosolized for concentrations of 1 and 1,000 legionellas per liter, respectively. Using a dose‐response model for guinea pigs to represent humans, infection risks for active whirlpool use with 100 cfu/L water for 15 minutes were 0.29 (∼0.11–0.48) for susceptible males and 0.22 (∼0.06–0.42) for susceptible females. A L. pneumophila concentration of ≥1,000 cfu/L water was estimated to nearly always cause an infection (mean: 0.95; 95% interval: 0.9–∼1). Estimated infection risks were time‐dependent, ranging from 0.02 (0–0.11) for 1‐minute exposures to 0.93 (0.86–0.97) for 2‐hour exposures when the L. pneumophila concentration was 100 cfu/L water. Pool water in Dutch bathing establishments should contain <100 cfu Legionella/L water. This study suggests that stricter provisions might be required to assure adequate public health protection.

Từ khóa


Tài liệu tham khảo

Hornei B, 2007, Legionella and the Prevention of Legionellosis

10.1128/CMR.15.3.506-526.2002

Bencini MA, 2005, Three patients with pneumonia due to Legionella associated with a sauna, a cooling tower and a caravan in the Netherlands, Ned Tijdschr Geneeskd, 149, 1973

Delia S, 2007, Occurrence of Legionella in beach shower facilities, Journal of Preventive Medicine and Hygiene, 48, 114

10.3201/eid0801.010176

Martinelli F, 2001, Detection of Legionella pneumophila at thermal spas, New Microbiology, 24, 259

10.1128/AEM.00944-10

10.1111/j.1539-6924.2007.00990.x

10.1093/ije/29.6.1092

Campese C, 2010, Cluster of Legionnaires’ disease associated with a public whirlpool spa, France, April–May 2010, Euro Surveillance, 15

10.3109/00365548.2010.509331

10.2166/wh.2008.026

10.4319/lo.1983.28.1.0101

10.1128/aem.43.5.1001-1005.1982

Hejkal TW, 1980, Water‐to‐air fractionation of bacteria, Applied and Environmental Microbiology, 39, 335, 10.1128/aem.39.2.335-338.1980

10.1016/S0013-9351(86)80003-2

10.1029/JC086iC09p08085

Anonymous, 1994, Human Respiratory Tract Model for Radiological Protection

10.1080/15459620701487539

10.1007/BF01089056

Anonymous.The engineering toolbox. Available at:http://www.engineeringtoolbox.com/water‐dynamic‐kinematic‐viscosity‐d_596.html Accessed on December 27 2010.

10.1086/324211

10.1111/j.1469-0691.2008.01973.x

Anonymous, 1991, Bacteriologisch onderzoek van water – onderzoek naar de aanwezigheid en het aantal kolonievormende eenheden (kve) van legionella‐bacteriën (nen 6265)

Vose D, 2000, Risk Analysis: A Quantitative Guide

10.1029/94JC00382

10.1175/1520-0485(2002)032<3286:JDPBBB>2.0.CO;2

10.1016/j.watres.2011.12.022

10.1111/j.1365-2672.2009.04208.x

10.1021/bp00013a003

Blander SJ, 1991, Vaccination with the major secretory protein of legionella induces humoral and cell‐mediated immune responses and protective immunity across different serogroups of Legionella pneumophila and different species of legionella, Journal of Immunology, 147, 285, 10.4049/jimmunol.147.1.285

10.1002/eji.200737591

10.1099/jmm.0.47382-0