Pulse oximetry: Principles and limitations

The American Journal of Emergency Medicine - Tập 17 - Trang 59-66 - 1999
James E Sinex1,2
1From the Department of Emergency Medicine, University of Cincinnati, Cincinnati, OH. USA
2the Department of Emergency Medicine, Medical College of Georgia, Augusta, GA. USA

Tài liệu tham khảo

Rodriguez, 1994, A study of pediatric house staff's knowledge of pulse oximetry, Pediatrics, 93, 810 Stoneham, 1994, Knowledge about pulse oximetry among medical and nursing staff, Lancet, 344, 1339, 10.1016/S0140-6736(94)90697-1 Kelleher, 1989, Pulse oximetry, J Clin Monit, 5, 37, 10.1007/BF01618369 Grace, 1994, Pulse oximetry, Med J Aust, 160, 638, 10.5694/j.1326-5377.1994.tb125873.x Tremper, 1989, Pulse oximetry, Anesthesiology, 70, 98, 10.1097/00000542-198901000-00019 Wukitsch, 1988, Pulse oximetry: analysis of theory, technology, and practice, J Clin Monit, 4, 290, 10.1007/BF01617328 Kidd, 1989, Pulse oximeters: essential monitors with limitations, Br J Anaesth, 62, 355, 10.1093/bja/62.4.355 Severinghaus, 1987, Accuracy of response of six pulse oximeters to profound hypoxemia, Anesthesiology, 67, 551, 10.1097/00000542-198710000-00017 Thrush, 1994, Accuracy of pulse oximetry during hypoxemia, South Med J, 87, 518, 10.1097/00007611-199404000-00019 Barker, 1987, The effect of carbon monoxide inhalation on pulse oximetry and transcultaneous PO2, Anesthesiology, 66, 677, 10.1097/00000542-198705000-00014 Seidler, 1993, Limitations of pulse oximetry, Lancet, 341, 1600, 10.1016/0140-6736(93)90740-8 Vegfors, 1991, Carboxyhaemoglobinaemia and pulse oximetry, Br J Anaesth, 66, 625, 10.1093/bja/66.5.625 Buckley, 1994, The pulse oximetry gap in carbon monoxide intoxication, Ann Emerg Med, 24, 252, 10.1016/S0196-0644(94)70137-7 Anderson, 1988, Benzocaine-induced methemoglobinemia in an adult: accuracy of pulse oximetry with methemoglobinemia, Anesth Analg, 67, 1099, 10.1213/00000539-198867110-00015 Eisenkraft, 1988, Pulse oximeter desaturation due to methemoglobinemia, Anesthesiology, 68, 279, 10.1097/00000542-198802000-00018 Barker, 1989, Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry, Anesthesiology, 70, 112, 10.1097/00000542-198901000-00021 Anderson, 1987, The accuracy of pulse oximetry in neonates: effects of fetal hemoglobin and bilirubin, J Perinatol, 7, 323 Ramanathan, 1987, Pulse oximetry in very low birth weight infants with acute and chronic disease, Pediatrics, 79, 612, 10.1542/peds.79.4.612 Harris, 1988, Absorption characteristics of human fetal hemoglobin at wavelengths used in pulse oximetry, J Clin Monit, 4, 175, 10.1007/BF01621812 Pologe, 1987, Effects of fetal hemoglobin on pulse oximetry, J Perinatol, 7, 324 Beall, 1989, Jaundice, oximetry, and spurious hemoglobin desaturation, Anesth Analg, 68, 806, 10.1213/00000539-198906000-00023 Veyckemans, 1989, Hyperbilirubinemia does not interfere with hemoglobin saturation measured by pulse oximetry, Anesthesiology, 70, 118, 10.1097/00000542-198901000-00022 Kessler, 1986, Spurious pulse oximeter desaturation with methylene blue injection, Anesthesiology, 65, 435, 10.1097/00000542-198610000-00017 Scheller, 1986, Effects of intravenously administered dyes on pulse oximetry readings, Anesthesiology, 65, 550, 10.1097/00000542-198611000-00023 Sidi, 1987, Methylene blue and indocyanine green artifactually lower pulse oximetry readings of oxygen saturation, J Clin Monit, 3, 249, 10.1007/BF03337379 Hanowell, 1987, Ambient light affects pulse oximeters, Anesthesiology, 67, 864, 10.1097/00000542-198711000-00057 Poets, 1993, Failure of pulse oximeter to detect sensor detachment, Lancet, 34, 244, 10.1016/0140-6736(93)90108-S Costarino, 1987, Falsely normal saturation reading with the pulse oximeter, Anesthesiology, 67, 830, 10.1097/00000542-198711000-00041 Southall, 1992, Inappropriate sensor application in pulse oximetry, Lancet, 340, 481, 10.1016/0140-6736(92)91799-E Gardosi, 1992, Inappropriate sensor application in pulse oximetry, Lancet, 340, 920, 10.1016/0140-6736(92)93338-N Kelleher, 1989, The penumbra effect: Vasomotion-dependent pulse oximeter artifact due to probe malposition, Anesthesiology, 71, 787, 10.1097/00000542-198911000-00028 Barker, 1993, The effect of sensor malpositioning on pulse oximeter accuracy during hypoxemia, Anesthesiology, 79, 248, 10.1097/00000542-199308000-00009 Hanning, 1995, Pulse oximetry: A practical review, BMJ, 311, 367, 10.1136/bmj.311.7001.367 Severinghaus, 1992, Recent developments in pulse oximetry, Anesthesiology, 76, 1018, 10.1097/00000542-199206000-00024 James, 1991, Pulse oximetry during apparent tonic-clonic seizures, Lancet, 337, 394, 10.1016/0140-6736(91)91168-T Moorthy, 1990, Erroneous pulse oximeter data during CPR, Anesth Analg, 70, 339, 10.1213/00000539-199003000-00028 Short, 1989, A comparison of pulse oximeters during helicopter flight, J Emerg Med, 7, 639, 10.1016/0736-4679(89)90012-7 Talke, 1988, Evaluation of pulse oximetry for intraoperative blood pressure measurement and vital sign monitoring during patient transport via life flight, Anesth Analg, 67, S229, 10.1213/00000539-198802001-00229 Talke, 1990, Monitoring patients during helicopter flight, J Clin Monit, 6, 139, 10.1007/BF02828291 Schnapp, 1990, Pulse oximetry—uses and abuses, Chest, 98, 1244, 10.1378/chest.98.5.1244 Severinghaus, 1990, Pulse oximeter failure thresholds in hypotension and vasoconstriction, Anesthesiology, 73, 532, 10.1097/00000542-199009000-00025 Evans, 1988, An assessment of blood vessel vasoactivity using photoplethysmography, Med Instrument, 22, 29 Bourke, 1991, Digital nerve blocks can restore pulse oximeter signal detection, Anesth Analg, 73, 815, 10.1213/00000539-199112000-00024 Gentili, 1995, Digital block of the flexor tendon sheathe can restore pulse oximeter signal detection, Reg Anesth, 20, 82 Grayson, 1991, Digital block for pulse oximetry failure, Anesthesiology, 75, A406, 10.1097/00000542-199109001-00407 Holroyd, 1993, Intraarterial vasodilator administration to restore pulse oximeter function, Anesthesiology, 79, 388, 10.1097/00000542-199308000-00027 Severinghaus, 1990, Effect of anemia on pulse oximeter accuracy at low saturation, J Clin Monit, 6, 85, 10.1007/BF02828282 Kolesar, 1990, Effect of haemoglobin concentration on the accuracy of pulse oximetry, Can J Anaesth, 37, S88 Vegfors, 1992, The accuracy of pulse oximetry at two haematocrit levels, Acta Anaesthesiol Scand, 36, 454, 10.1111/j.1399-6576.1992.tb03496.x Lee, 1988, Effects of anemia on pulse oximetry and continuous mixed venous oxygen saturation monitoring in dogs, Anesth Analg, 67, S130, 10.1213/00000539-198802001-00130 Jay, 1994, Pulse oximetry is accurate in acute anemia from hemorrhage, Ann Emerg Med, 24, 32, 10.1016/S0196-0644(94)70158-X Cahan, 1990, Agreement between noninvasive oximetric values for oxygen saturation, Chest, 97, 814, 10.1378/chest.97.4.814 Ries, 1989, Skin color and ear oximetry, Chest, 96, 287, 10.1378/chest.96.2.287 Volgyesi, 1991, Does skin pigmentation affect the accuracy of pulse oximetry?, Anesthesiology, 75, A406, 10.1097/00000542-199109001-00406 Cote, 1988, The effect of nail polish on pulse oximetry, Anesth Analg, 67, 683 Kataria, 1986, Nail polish does not affect pulse oximetry saturation, Anesth Analg, 65, 824, 10.1213/00000539-198607000-00029 Rubin, 1988, Nail polish color can affect pulse oximetry, Anesthesiology, 68, 825, 10.1097/00000542-198805000-00049 Severinghaus, 1993, History and recent developments in pulse oximetry, Scand J Clin Lab Invest, 53, 105, 10.3109/00365519309090686 Jones, 1988, Continuous emergency department monitoring of arterial saturation in adult patients with respiratory distress, Ann Emerg Med, 17, 463, 10.1016/S0196-0644(88)80237-3 Mateer, 1993, Continuous pulse oximetry during emergency endotracheal intubation, Ann Emerg Med, 22, 675, 10.1016/S0196-0644(05)81846-3 Holburn, 1989, Pulse oximetry in the accident and emergency department, Arch Emerg Med, 6, 137, 10.1136/emj.6.2.137 Lambert, 1989, The role of pulse oximetry in the accident and emergency department, Arch Emerg Med, 6, 211, 10.1136/emj.6.3.211 Mower, 1995, Effect of routine emergency department triage pulse oximetry screening on medical management, Chest, 108, 1297, 10.1378/chest.108.5.1297 Narang, 1986, Utility of the pulse oximeter during cardiopulmonary resuscitation, Anesthesiology, 65, 239, 10.1097/00000542-198608000-00039 Levinsohn, 1991, The Allen's test: Analysis of four methods, J Hand Surg [Am], 16A, 279, 10.1016/S0363-5023(10)80111-X O'Mara, 1995, A simple bedside test to identify ulnar collateral flow, Ann Intern Med, 123, 637, 10.7326/0003-4819-123-8-199510150-00027 Fuhrman, 1995, Noninvasive evaluation of the collateral circulation of the hand, Acad Emerg Med, 2, 195, 10.1111/j.1553-2712.1995.tb03196.x Graham, 1986, Pulse oximetry for vascular monitoring in upper extremity replantation surgery, J Hand Surg [Am], 11A, 687, 10.1016/S0363-5023(86)80013-2 Lawson, 1987, Blood flow limits and pulse oximeter signal detection, Anesthesiology, 67, 599, 10.1097/00000542-198710000-00032 Talke, 1990, Does systolic blood pressure measured using a pulse oximeter correlate with conventional methods?, J Clin Monit, 6, 5, 10.1007/BF02832176 Wallace, 1987, Comparison of blood pressure measurement by Doppler and by pulse oximetry techniques, Anesth Analg, 66, 1018, 10.1213/00000539-198710000-00019 Chawla, 1992, Can pulse oximetry be used to measure systolic blood pressure?, Anesth Analg, 74, 196, 10.1213/00000539-199202000-00004 de Kock, 1993, Reflectance pulse oximetry readings from the retinal fundus, IEEE Trans Biomed Eng, 40, 817, 10.1109/10.238467 Dougherty, 1992, Design and evaluation of an instrument to measure microcirculatory blood flow and oxygen saturation simultaneously, J Med Eng Technol, 16, 123, 10.3109/03091909209021974 Jorgensen, 1995, Limitations of forehead pulse oximetry, J Clin Monit, 11, 253, 10.1007/BF01617520 Lindberg, 1995, Pulse oximetry—clinical implications and recent technical developments, Acta Anaesthesiol Scand, 39, 279, 10.1111/j.1399-6576.1995.tb04062.x