Tài liệu tham khảo
Salonikios, 1999, Cyclic load behavior of low-slenderness R/C walls: design basis and test results, ACI Struct J, 96, 649
Salonikios, 2000, Cyclic load behavior of low-slenderness R/C walls: failure modes, strength and deformation analysis, and design implications, ACI Struct J, 97, 132
Hidalgo, 2002, Seismic behavior of squat reinforced concrete shear walls, Earthquake Spectra, 18, 287, 10.1193/1.1490353
Salonikios, 2002, Shear strength and deformation patterns of R/C walls with aspect ratio 1.0 and 1.5 designed to Eurocode 8 (EC8), Eng Struct, 24, 39, 10.1016/S0141-0296(01)00076-1
Rezaifar, 2008, Dynamic behaviour of 3D-panel single-storey system using shakingtable testing, Eng Struct, 30, 318, 10.1016/j.engstruct.2007.03.019
Precast/Prestressed Concrete Institute. PCI design handbook—precast and prestressed concrete. 6th ed. Chicago, IL: Precast/Prestressed Concrete Institute; 2004.
Vanderwerf, 1997
Vanderwerf, 2005
Paulay, 1992
Ricci I. Sistemi strutturali cellulari a pareti portanti in cemento armato gettato in opera realizzate con la tecnologia del pannello di supporto in polistirene. Ph.D Thesis. Department DICAM, University of Bologna; 2012 [in Italian]. <http://amsdottorato.cib.unibo.it/4886/>.
Palermo, 2012, In-plane shear behaviour of thin low reinforced concrete panels for earthquake re-construction, Mater Struct, 46, 841, 10.1617/s11527-012-9937-8
Coull, 1991
Taranath, 1997
Fajfar P, Duhovnik J, Reflak J, Fischinger M, Breska Z. The behavior of buildings and other structures during the earthquakes of 1979 in Montenegro. IKPIR publication no. 19A. University of Ljubljana; 1981.
Wood, 1991, Performance of reinforced concrete buildings during the 1985 Chile earthquake: implications for the design of structural walls, Earthquake Spectra, 7, 607, 10.1193/1.1585645
Nidyon Costruzioni S.p.a web site: <http://www.nidyon.net/it/nidyon-costruzioni-srl-64.php>.
Ricci, 2013, Results of pseudo-static tests with cyclic horizontal load on cast in situ sandwich squat concrete walls, Eng Struct, 54, 131, 10.1016/j.engstruct.2013.03.046
Norme Tecniche per le Costruzioni. ItalianMinisterial Decree of 14 January 2008. Published in the GazzettaUfficale n. 29 of 04 Feb 2008, Suppl. Ordinario n. 30; 2008 [in Italian].
UNI EN 10016-2:1996. Vergella di acciaio non legato destinata alla trafilatura e/o laminazione a freddo. Prescrizioni specifiche per vergella per impieghi generali [in Italian].
SAP 200 v15.0. Computer & structures.
Vecchio, 1986, The modified compression field theory for reinforced concrete elements subjected to shear, J Am Concr Inst, 83, 219
Membrane 2000. <www.ecf.utoronto.ca/∗bentz/m2k.htm>.