Predictors of atrial mechanical sensing and atrioventricular synchrony with a leadless ventricular pacemaker: Results from the MARVEL 2 Study
Tài liệu tham khảo
Lamas, 1998, Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. Pacemaker Selection in the Elderly Investigators, N Engl J Med, 338, 1097, 10.1056/NEJM199804163381602
Connolly, 2000, Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. Canadian Trial of Physiologic Pacing Investigators, N Engl J Med, 342, 1385, 10.1056/NEJM200005113421902
Lamas, 2004, Evidence base for pacemaker mode selection: from physiology to randomized trials, Circulation, 109, 443, 10.1161/01.CIR.0000115642.05037.0E
Kusumoto, 2019, Circulation, 140, e382
Udo, 2012, Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study, Heart Rhythm, 9, 728, 10.1016/j.hrthm.2011.12.014
Neuzil, 2015, Leadless Cardiac pacemakers: pacing paradigm change, Curr Cardiol Rep, 17, 68, 10.1007/s11886-015-0619-3
Mont, 2018, Risk factors for cardiac perforation/effusion in leadless pacemaker patients: experience with the Micra transcatheter pacemaker. (Abstract), Heart Rhythm, 15, S1
Chinitz, 2018, Accelerometer-based atrioventricular synchronous pacing with a ventricular leadless pacemaker: results from the Micra atrioventricular feasibility studies, Heart Rhythm, 15, 1363, 10.1016/j.hrthm.2018.05.004
Steinwender, 2020, Atrioventricular synchronous pacing using a leadless ventricular pacemaker: results from the MARVEL 2 Study, JACC Clin Electrophysiol, 6, 94, 10.1016/j.jacep.2019.10.017
Bazaz, 2008, Evidence of robust coupling of atrioventricular mechanical function of the right side of the heart: insights from M-mode analysis of annular motion, Echocardiography, 25, 557, 10.1111/j.1540-8175.2008.00676.x
Sivak, 2016, Assessment of the physiologic contribution of right atrial function to total right heart function in patients with and without pulmonary arterial hypertension, Pulm Circ, 6, 322, 10.1086/687767
Shaffer, 2017, An overview of heart rate variability metrics and norms, Front Public Health, 5, 258, 10.3389/fpubh.2017.00258
Van Campen, 2001, Clinical relevance of loss of atrial sensing in patients with single lead VDD pacemakers, Pacing Clin Electrophysiol, 24, 806, 10.1046/j.1460-9592.2001.00806.x
Crick, 1991, European multicenter prospective follow-up study of 1,002 implants of a single lead VDD pacing system. The European Multicenter Study Group, Pacing Clin Electrophysiol, 14, 1742, 10.1111/j.1540-8159.1991.tb02757.x
Hunziker, 1998, Predictors of loss of atrioventricular synchrony in single lead VDD pacing, Heart, 80, 390, 10.1136/hrt.80.4.390
Huang, 2010, Predictors of inappropriate atrial sensing in long-term VDD-pacing systems, Europace, 12, 12511255, 10.1093/europace/euq190
van Buuren, 2011, mice: Multivariate imputation by chained equations in R, J Stat Softw, 45, 1
Friedman, 2010, Regularization paths for generalized linear models via coordinate descent, J Stat Softw, 33, 1, 10.18637/jss.v033.i01
Sing, 2005, ROCR: visualizing classifier performance in R, Bioinformatics, 21, 3940, 10.1093/bioinformatics/bti623
Abdelghani Abdelzaher, 2014, Left atrial geometry and pump function in ischemic cardiomyopathy, Int J Cardiol Heart Vasc, 5, 45
Buber, 2014, Morphological features of the P-waves at surface electrocardiogram as surrogate to mechanical function of the left atrium following a successful modified maze procedure, Europace, 16, 578, 10.1093/europace/eut248
Toff, 2005, United Kingdom Pacing and Cardiovascular Events Trial Investigators. Single-chamber versus dual-chamber pacing for high-grade atrioventricular block, N Engl J Med, 353, 145, 10.1056/NEJMoa042283
Marchandise, 2012, Long-term follow-up of DDD and VDD pacing: a prospective non-randomized single-centre comparison of patients with symptomatic atrioventricular block, Europace, 14, 496, 10.1093/europace/eur345
Wiegand, 1999, Development of sinus node disease in patients with AV block: implications for single lead VDD pacing, Heart, 81, 580, 10.1136/hrt.81.6.580