Predictors and Clinical Outcomes of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement

JACC: Cardiovascular Interventions - Tập 8 Số 1 - Trang 60-69 - 2015
Tamim Nazif1, José Dizon1, Rebecca T. Hahn1, Ke Xu2, Vasilis Babaliaros3, Pamela S. Douglas4, Mikhael F. El‐Chami3, Howard C. Herrmann5, Michael J. Mack6, Raj Makkar7, D. Craig Miller8, Augusto D. Pichard9, E. Murat Tuzcu10, Wilson Y. Szeto5, John G. Webb11, Jeffrey W. Moses1, Mathew Williams1, Martin B. Leon1, Susheel Kodali12
1Columbia University Medical Center, New York, New York
2Cardiovascular Research Foundation, New York, New York
3Emory University School of Medicine, Atlanta, Georgia
4Duke Clinical Research Institute, Durham, North Carolina
5Hospital of the University of PennsylvaniaPhiladelphia, Pennsylvania
6Baylor Healthcare System, Plano, Texas
7Cedars-Sinai Medical Center, Los Angeles, California
8Stanford University School of Medicine, Stanford, California
9Medstar Washington Hospital Center, Washington, DC
10Cleveland Clinic, Cleveland, Ohio
11St. Paul's Hospital, Vancouver, British Columbia, Canada
12Columbia University Medical Center

Tóm tắt

Từ khóa


Tài liệu tham khảo

Leon, 2010, Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery, N Engl J Med, 363, 1597, 10.1056/NEJMoa1008232

Smith, 2011, Transcatheter versus surgical aortic-valve replacement in high-risk patients, N Engl J Med, 364, 2187, 10.1056/NEJMoa1103510

Erkapic, 2012, Risk for permanent pacemaker after transcatheter aortic valve implantation: a comprehensive analysis of the literature, J Cardiovasc Electrophysiol, 23, 391, 10.1111/j.1540-8167.2011.02211.x

Khatri, 2013, Adverse effects associated with transcatheter aortic valve implantation: a meta-analysis of contemporary studies, Ann Intern Med, 158, 35, 10.7326/0003-4819-158-1-201301010-00007

Jilaihawi, 2012, Meta-analysis of complications in aortic valve replacement: comparison of Medtronic-Corevalve, Edwards-Sapien and surgical aortic valve replacement in 8,536 patients, Catheter Cardiovasc Interv, 80, 128, 10.1002/ccd.23368

Douglas, 2013, Implementation of echocardiography core laboratory best practices: a case study of the PARTNER I trial, J Am Soc Echocardiogr, 26, 348, 10.1016/j.echo.2013.01.013

Friedman, 1978, Assessment of atrioventricular conduction in aortic valve disease, Br Heart J, 40, 911, 10.1136/hrt.40.8.911

Piazza, 2008, Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve, Circ Cardiovasc Interv, 1, 74, 10.1161/CIRCINTERVENTIONS.108.780858

Fukuda, 1976, Lesions of conduction tissue complicating aortic valvular replacement, Chest, 69, 605, 10.1378/chest.69.5.605

Moreno, 2009, Cause of complete atrioventricular block after percutaneous aortic valve implantation: insights from a necropsy study, Circulation, 120, e29, 10.1161/CIRCULATIONAHA.109.849281

Sinhal, 2008, Atrioventricular block after transcatheter balloon expandable aortic valve implantation, J Am Coll Cardiol Intv, 1, 305, 10.1016/j.jcin.2007.12.009

Bagur, 2011, Permanent pacemaker implantation following isolated aortic valve replacement in a large cohort of elderly patients with severe aortic stenosis, Heart, 97, 1687, 10.1136/heartjnl-2011-300308

Dawkins, 2008, Permanent pacemaker implantation after isolated aortic valve replacement: incidence, indications, and predictors, Ann Thorac Surg, 85, 108, 10.1016/j.athoracsur.2007.08.024

Erdogan, 2006, Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement, J Cardiac Surg, 21, 211, 10.1111/j.1540-8191.2006.00216.x

Adams, 2014, Transcatheter aortic-valve replacement with a self-expanding prosthesis, N Engl J Med, 370, 1790, 10.1056/NEJMoa1400590

Popma, 2014, Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery, J Am Coll Cardiol, 63, 1972, 10.1016/j.jacc.2014.02.556

Tzamtzis, 2013, Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI), Med Eng Phys, 35, 125, 10.1016/j.medengphy.2012.04.009

Urena, 2014, Permanent pacemaker implantation following transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function, Circulation, 129, 1233, 10.1161/CIRCULATIONAHA.113.005479

Goldenberg, 2013, Pacemaker implantation after transcatheter aortic valve implantation, Am J Cardiol, 112, 1632, 10.1016/j.amjcard.2013.07.022

van der Boon, 2013, Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System, Int J Cardiol, 168, 1269, 10.1016/j.ijcard.2012.11.115

Pereira, 2013, Transcatheter aortic valve implantation and requirements of pacing over time, Pacing Clin Electrophysiol, 36, 559, 10.1111/pace.12104

De Carlo, 2012, Safety of a conservative strategy of permanent pacemaker implantation after transcatheter aortic CoreValve implantation, Am Heart J, 163, 492, 10.1016/j.ahj.2011.12.009

Ledwoch, 2013, Incidence and predictors of permanent pacemaker implantation following transcatheter aortic valve implantation: analysis from the german transcatheter aortic valve interventions registry, Catheter Cardiovasc Interv, 82, E569, 10.1002/ccd.24915

Bagur, 2012, Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings, J Am Coll Cardiol Intv, 5, 540, 10.1016/j.jcin.2012.03.004

Fraccaro, 2013, Conduction disorders in the setting of transcatheter aortic valve implantation: a clinical perspective, Catheter Cardiovasc Interv, 81, 1217, 10.1002/ccd.24713

Khawaja, 2011, Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve Collaborative), Circulation, 123, 951, 10.1161/CIRCULATIONAHA.109.927152

Binder, 2013, Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation, J Am Coll Cardiol Intv, 6, 462, 10.1016/j.jcin.2012.12.128

Munoz-Garcia, 2012, Factors predicting and having an impact on the need for a permanent pacemaker after CoreValve prosthesis implantation using the new Accutrak delivery catheter system, J Am Coll Cardiol Intv, 5, 533, 10.1016/j.jcin.2012.03.011

Baan, 2010, Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis, Am Heart J, 159, 497, 10.1016/j.ahj.2009.12.009

Wilkoff, 2002, Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) trial, JAMA, 288, 3115, 10.1001/jama.288.24.3115

Sweeney, 2003, Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction, Circulation, 107, 2932, 10.1161/01.CIR.0000072769.17295.B1

Curtis, 2013, Biventricular pacing for atrioventricular block and systolic dysfunction, N Engl J Med, 368, 1585, 10.1056/NEJMoa1210356

Buellesfeld, 2012, Impact of permanent pacemaker implantation on clinical outcome among patients undergoing transcatheter aortic valve implantation, J Am Coll Cardiol, 60, 493, 10.1016/j.jacc.2012.03.054

Abraham, 2002, Cardiac resynchronization in chronic heart failure, N Engl J Med, 346, 1845, 10.1056/NEJMoa013168

Cazeau, 2001, Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay, N Engl J Med, 344, 873, 10.1056/NEJM200103223441202

Tse, 2002, Functional abnormalities in patients with permanent right ventricular pacing: the effect of sites of electrical stimulation, J Am Coll Cardiol, 40, 1451, 10.1016/S0735-1097(02)02169-1

Hoffmann, 2012, Impact of a new conduction defect after transcatheter aortic valve implantation on left ventricular function, J Am Coll Cardiol Intv, 5, 1257, 10.1016/j.jcin.2012.08.011

Nazif, 2014, Clinical implications of new-onset left bundle branch block after transcatheter aortic valve replacement: analysis of the PARTNER experience, Eur Heart J, 35, 1599, 10.1093/eurheartj/eht376

Urena, 2012, Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve, J Am Coll Cardiol, 60, 1743, 10.1016/j.jacc.2012.07.035

Meguro, 2012, Cardiac resynchronization therapy improved heart failure after left bundle branch block during transcatheter aortic valve implantation, J Invasive Cardiol, 24, 132

Osmancik, 2011, Cardiac resynchronization therapy implantation following transcatheter aortic valve implantation, Europace, 13, 290, 10.1093/europace/euq336