Precisión de la resonancia magnética, ecografía y mamografía en la medida del tamaño tumoral y su correlación con el tamaño histopatológico en el cáncer de mama primario

Cirugía Española - Tập 97 - Trang 391-396 - 2019
Ana Belén Cuesta Cuesta1, María Dolores Martín Ríos2, María Rosario Noguero Meseguer3, Juan Antonio García Velasco4, María de Matías Martínez1, Sara Bartolomé Sotillos1, Eduardo Abreu Griego1
1Unidad de Mama, Servicio de Ginecología y Obstetricia, Hospital Universitario Rey Juan Carlos, Móstoles, Madrid, España
2Servicio de Medicina Preventiva, Hospital Universitario Rey Juan Carlos, Universidad Rey Juan Carlos, Móstoles, Madrid, España
3Unidad de Mama, Servicio de Ginecología y Obstetricia, Hospital Universitario Rey Juan Carlos, Universidad Rey Juan Carlos, Móstoles, Madrid, España
4Universidad Rey Juan Carlos, Móstoles, Madrid, España

Tài liệu tham khảo

American College of Radiology (ACR). Breast Imaging Reporting and Data System Altlas (BI-RADS Atlas). 4th ed. Reston, VA; 2003. Madjar, 2006, BIRADS-Analogue degum criteria for findings in breast ultrasound —Consensus of the DEGUM Committee on Breast Ultrasound, Ultraschall Med., 27, 374, 10.1055/s-2006-926943 Berg, 2004, Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preop- erative assessment of breast cancer, Radiology., 233, 830, 10.1148/radiol.2333031484 Vandermeer, 2007, Breast MRI. State of the art, Cancer Invest., 25, 384, 10.1080/07357900701360013 Orel, 2001, MR imaging of the breast for the detection, diagnosis, and staging of breast cancer, Radiology., 220, 13, 10.1148/radiology.220.1.r01jl3113 Hieken, 2001, Correlating sonography, mammography, and pathology in the assessment of breast cancer size, Am J Surg., 182, 351, 10.1016/S0002-9610(01)00726-7 Kolb, 2002, Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: An analysis of 27,825 patient evaluations, Radiology., 225, 165, 10.1148/radiol.2251011667 Sardanelli, 2004, Sensitivity of MRI versus mammography for detecting foci of multifocal, multicentric breast cancer in fatty and dense breasts using the whole breast pathologic examination as a gold standard, AJR Am J Roentgenol., 183, 1149, 10.2214/ajr.183.4.1831149 Mandelson, 2000, Breast density as a predictor of mammographic detection: Comparison of interval-and screen-detected cancers, J Natl Cancer Inst., 92, 1081, 10.1093/jnci/92.13.1081 Leddy, 2016, Comparative Accuracy of preoperative tumor size assessment on mammography, sonography, and MRI: Is the accuracy affected by breast density or cancer subtype?, J Clin Ultrasound., 44, 17, 10.1002/jcu.22290 Hung-Wen, 2015, Comparison of the diagnostic accuracy of magnetic resonance imaging with sonography in the prediction of breast cancer tumor size: A concordance analysis with histopathologically determined tumor size, Ann Surg Oncol., 22, 3816, 10.1245/s10434-015-4424-4 Gruber, 2013, Measurement of tumour size with mammography, sonography and magnetic resonance imaging as compared to histological tumour size in primary breast cancer, BMC Cancer., 13, 328, 10.1186/1471-2407-13-328 Bosch, 2003, Preoperative estimation of the pathological breast tumour size by physical examination, mammography and ultrasound: A prospective study on 105 invasive tumours, Eur J Radiol., 48, 285, 10.1016/S0720-048X(03)00081-0 Shoma, 2006, Ultrasound for accurate measurement of invasive breast cancer tumor size, Breast J., 12, 252, 10.1111/j.1075-122X.2006.00249.x Kopans, 1985, Whole-breast U.S. imaging: Four-year follow-up, Radiology., 157, 505, 10.1148/radiology.157.2.3901112 Yang, 2004, Sonographic, mammographic, and histopathologic correlation of symptomatic ductal carcinoma in situ, AJR Am J Roentgenol., 182, 101, 10.2214/ajr.182.1.1820101 Soo, 2003, Sonographic detection and sonographically guided biopsy of breast microcalcifications, AJR Am J Roentgenol., 180, 941, 10.2214/ajr.180.4.1800941 Pritt, 2004, Influence of breast cancer histology on the relationship between ultrasound and pathology tumor size measurements, Mod Pathol., 17, 905, 10.1038/modpathol.3800138 Skaane, 1999, Ultrasonographic evaluation of invasive lobular carcinoma, Act Radiol., 40, 369, 10.3109/02841859909177749 Onesti, 2008, Breast cancer tumor size: Correlation between magnetic resonance imaging and patholog measurements, Am J Surg., 196, 844, 10.1016/j.amjsurg.2008.07.028 Luparia, 2013, Accuracy of tumour size assessment in the preoperative staging of breast cancer: comparison of digital mammography, tomosynthesis, ultrasound and MRI, Radiol Med., 118, 1119, 10.1007/s11547-013-0941-z Rodenko, 1996, MR imaging in the management before surgery of lobular carcinoma of the breast: Correlation with pathology, Am J Roentgenol., 167, 1415, 10.2214/ajr.167.6.8956569 Cortadellas, 2017, Estimation of tumor size in breast cancer comparing clinical examination, mammography, ultrasound and MRI—correlation with the pathological analysis of the surgical specimen, Gland Surg., 6, 330, 10.21037/gs.2017.03.09 Katz, 2017, Predicting breast tumor size for pre-operative planning: Which imaging modality is best?, Breast J., 23, 52, 10.1111/tbj.12680 Wasif, 2009, MRI versus ultrasonography and mammography for preoperative assessment of breast cancer, Am Surg., 75, 970, 10.1177/000313480907501024 Davis, 1996, Breast cancer measurements with magnetic resonance imaging, ultrasonography, and mammography, Breast Cancer Res Treat., 37, 1, 10.1007/BF01806626 Boetes, 1995, Breast tumors: comparative accuracy of MR imaging relative to mammography and US for demonstrating extent, Radiology., 197, 743, 10.1148/radiology.197.3.7480749 Pop, 2018, The impact of breast MRI workup on tumor size assessment and surgical planning in patients with early breast cancer, Breast J., 24, 927, 10.1111/tbj.13104 Tseng, 2017, Clinical accuracy of preoperative breast MRI for breast cancer, J Surg Oncol., 115, 924, 10.1002/jso.24616