Batz L, Irnich W (1995) Störbeeinflussung von Herzschrittmachern durch Identifikationssysteme. Herzschrittmacherther Elektrophysiol 5:130–135
Da Costa A, Kirkorian G, Isaaz K, Touboul P (2000) Secondary infections after pacemaker implantation. Rev Med Interne 21:256–265
Daley WR, Kaczmarek RG (1998) The epidemiology of cardiac pacemakers in the older US population. J Am Geriatr Soc 46:1016–1019
Geppert A, Rauscha F (2001) Schrittmacherdysfunktion in der klinischen Praxis. Wien Klin Wochenschr 113:15–26
Grobety M, Perret F, Schlaepfer J, Kappenberger L (1996) Cardiac pacemaker dysfunction secondary to outside interference: a review. Schweiz Med Wochenschr 126:723–733
Hayes DL, Carrillo RG, Findlay GK, Embrey M (1996) State of the science: pacemaker and defibrillator interference from wireless communication devices. Pacing Clin Electrophysiol 19:1419–1430
Irnich W (1999) Pacemaker-related patient mortality. Pacing Clin Electrophysiol 22:1279–1283
Irnich W, Schmitt F (1995) Magnetostimulation in MRI. Magn Reson Med 33:619–623
Irnich W, Batz L, Müller R, Tobisch R (1996) Electromagnetic interference of pacemakers. Pacing Clin Electrophysiol 19:1431–1446
Irnich W, Stertmann WA, Müller R, Rempe M, Hehrlein FW (1997) How to detect defective bipolar leads. In: Vardas PE (eds) Europace '97. Monduzzi Editore, Bologna, pp 815–819
Kamke W, Breitkreuz B, Jereczek M, Dovifat C, Völler H (2002) Nachweis und Bedeutung von permanenten und transitorischen Schrittmacherfunktionsstörungen bei 180 Patienten mit Ein- und Zwei-Kammer-Aggregaten. Herzschr Elektrophys 13:233–241
Kawanishi D, Brinker J, Reeves R, Kay N, Gross J, Peeters K, Fee J (2002) Severe underreporting of mortality in patients with the Accufix atrial pacemaker lead: implications for estimation of population survival after pacemaker implantation. Pacing Clin Electrophysiol 24: Abstract # 303, 598
Last A (1998) Radiotherapy in patients with cardiac pacemakers. Br J Radiol 71:4–10
Markewitz A (2002) Jahresbericht 2000/2001 des Deutschen Zentralregisters Herzschrittmacher. Herzschr Elektrophys 13:242–257
Muller-Runkel R, Orsolini G, Kalokhe UP (1990) Monitoring the radiation dose to a multiprogrammable pacemaker during radical radiation therapy: a case report. Pacing Clin Electrophysiol 13:1466–1470
Nibhanupudy JR, Jesus MA de, Fujita M, Goldson AL (2001) Radiation dose monitoring in a breast cancer patient with a pacemaker: a case report. J Natl Med Assoc 93:278–281
Pachulski R, Zasadil M, Adkins D, Hanif B (2002) High incidence of Pellethane 90 A lead malfunction. Europace 4:45–47
Serafim P, Fonseca G, Oliveira A, Fernandes T (1999) Radiation therapy and cardiac pacemakers. Rev Port Cardiol 18:503–505
Seshadri N, Acharya N, Abdul-Karim A et al. (2002) Higher mortality in patients with polyurethane pacemaker lead insulation. Pacing Clin Electrophysiol 24: Abstract # 478, 642
Teskey RJ, Whelan I, Akyurekli Y, Eapen L, Green MS (1991) Therapeutic irradiation over a permanent cardiac pacemaker. Pacing Clin Electrophysiol 14:143–145
Valhaus C, Sommer T, Lewalter T, Schimpf R, Schumacher B, Jung W, Luderitz B (2001) Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 Tesla? Pacing Clin Electrophysiol 24:489–495
Venselaar JLM, Kerkoerle HLJM van, Vet AJTM (1987) Radiation damage to pacemakers from radiotherapy. Pacing Clin Electrophysiol 10:538–542