Poly(vinylferrocene)–poly(ethylene glycol) glutamate oxidase electrode for determination of L-glutamate in commercial soy sauces
Tóm tắt
An amperometric L-glutamate oxidase (GLOD) electrode based on a multilayer of polymer films was developed for the high selective determination of L-glutamate. The multilayer film consisted of three layers as the following configuration i.e., inner membrane of electropolymerized 1,3-diaminobenzene, middle layer of L-GLOD entrapped in photopolymerized poly(vinylferrocene)–poly(ethylene glycol) hydrogel polymer, and outer dialysis membrane. In this manner, the sensor could eliminate interferences and was able to work at a low potential poised at +0.085 V vs. Ag/AgCl. When used in a flow injection system, the sensor responded to L-glutamate in the range 0.5–8.0 mM, with a sensitivity of 9.48 nA mM−1. The sensor was stable for 5 days of continuous uses (250 assays) and retained 60% activity after 16 days. When used to analyse the L-glutamate contents of a number of different off-the-shelf soy sauces, the sensor gave results in good agreement with the standard colorimetric method.
Tài liệu tham khảo
Almeida, N.F. & Mulchandani, A.K.A. 1993 Mediated amperometric enzyme electrode using tetrathiafulvalene and glutamate oxidase for the determination of L-glutamic acid. Analytica Chimica Acta 282, 353-361.
Belay, A., Collins, A., Ruzgas, T., Kissinger, P.T., Gontan, L. & Csoregi, E. 1999 Redox hydrogel based bienzyme electrode for L-glutamate monitoring. Journal of Pharmaceutical and Biomedical Analysis 19, 93-105.
Beutler, H.-O. 1985. In Methods of Enzymatic Analysis. 3rd edn. vol. 8, ed. Bergmeyer, H.U. pp. 369-376. Weinhiem: Verlag Chemie. ISBN 3-52726048-X.
Chen, C.Y. & Su, Y.C. 1991 Amperometric L-glutamate sensor using a novel L-glutamate oxidase from Streptomyces platensis NTU 3304. Analytica Chimica Acta 243, 9-15.
Cooper, J.M. & Prichard, D.J. 1994 Biomolecular sensors for neurotransmitter determination-electrochemical immobilization of glutamate oxidase at microelectrodes in a poly(o-phenylenediamine) film. Journal of Materials Science 5, 111-116.
Cooper, J.M., McNeil, C.J. & Spoors, J.A. 1991 Amperometric enzyme electrode for the determination of aspartate-aminotransferase and alanine aminotransferase in serum. Analytica Chimica Acta 245, 57-62.
Hale, P.D., Lee, H-S., Okamato, Y. & Skotheim, T.A. 1991 Glutamate biosensors based on electrical communication between L-glutamate oxidase and a flexible redox polymer. Analytical Letters 24, 345-356.
Jager, A. & Bilitewski, U. 1994 Screen-printed enzyme electrode for the determination of lactose. Analyst 119, 1251-1255.
Janasek, D. & Spohn, U. 1999 Chemiluminometric flow injection analysis procedures for the enzymatic determination of L-alanine, (?-ketoglutarate and L-glutamate. Biosensors and Bioelectronics 14, 123-129.
Kapetanovic, I.M., Yonekawa, W.D. & Kupferverg, H.J. 1987 Determination of 4-aminobutyric acid, aspartate, glutamate and glutamine and their 13C stable-isotopic enrichment in brain tissue by gas chromatography-mass spectrophotometry. Journal of Chromatography 414, 265-274.
Lu, W.M. & Chen, W.C. 1989 Theoretical and experimental studies on an immobilized L-glutamate decarboxylase electrode. Proceedings of the National Science Council, Republic of China, Part A Applied Sciences 13, 120-129.
Miller, J.C. & Miller, J.N. 1993 Statistics for Analytical Chemistry. 3rd edn, pp. 58-59. New York: Ellis Horwood. ISBN 0-13-030990-7.
Moser, I., Jobst, G., Aschauer, E., Svasek, P., Varahram, M. & Urban, G. 1995 Miniaturized thin film glutamate and glutamine biosensors. Biosensors and Bioelectronics 10, 527-532.
Mulchandani, A. & Bassi, A.S. 1996 Determination of glutamine and glutamic acid in mammalian cell cultures using tetrathiafulvalene modified enzyme electrodes. Biosensors and Bioelectronics 11, 271-280.
Nikolelis, D.P. 1987 Kinetic-potentiometric determination of monosodium glutamate in soups and soup based and of glutamate dehydrogenase. Analyst 112, 763-765.
Norris, D.K., Murphy, R.A. & Chung, S.H. 1985 Alteration of amino acid metabolism in epoleptogenic mice by elevation of brain pyridoxal phosphate. Journal of Neurochemistry 44, 1403-1410.
O'Shea, T.J., Weber, P.L., Bammel, B.P., Lunte, C.E., Lunte, S.M. & Smyth, M.R. 1992 monitoring excitatory amino-acid release in vivo by micro-dialysis with capillary electrophoresis electrochemistry. Journal of Chromatography 608, 189-195.
Qingshan, L. 1995 1,1?(dimethylferroncene mediated L-glutamate electrodes modified with electropolymerized 1,3-diaminobenzene film. Analytical Letters 28, 2161-2174.
Sirkar, K. & Pishko, M.V. 1998 Amperometric biosensors based on oxidoreductases immobilized in photopolymerized poly(ethylene glycol) redox polymer hydrogels. Analytical Chemistry 70, 2888-2894.
Udomsopagit, S., Suphantharika, M., Kunnecke, W., Bilitewski, U. & Bhumiratana, A. 1998 Determination of L-glutamate in various commercial soy sauce products using flow injection analysis with a modified electrode. World Journal of Microbiology and Biotechnology 14, 543-549.
Vahjen, W., Bradley, J., Billtewski, U. & Schmid, R.D. 1991 Mediated enzyme electrode for the determination of L-glutamate. Analytical Letters 24, 1445-1452.
Villarta, R.L., Cunningham, D.D. & Guilbault, G.G. 1991 Amperometric enzyme electrodes for the determination of L-glutamate. Talanta 38, 49-55.
Westerberh, E., Chapman, A.G. & Meldrum, B.S. 1983 Effect of 2-amino-7-phosphono-haptanic acid on regional brain amino acid levels in feed and fast rodents. Journal of Neurochemistry 41, 1755-1760.
White, S.F., Turner, A.P.F., Bilitewski, J., Bradley U. & Schmid, R.D. 1995 On-line monitoring of glucose, glutamate and glutamine during mammalian cell cultivations. Biosensors and Bioelectronics 10, 543-551.
White, S.F., Turner, A.P.F., Bilitewski, U., Schmid, R.D. & Bradley, J. 1994 Lactate, glutamate and glutamine biosensors based on rhodiumized carbon electrodes. Analytica Chimica Acta 295, 243-251.
Wollenberger, U., Scheller, F.W., Böhmer, A., Passarge, M. & Müller, H-G. 1989 A specific enzyme electrode for L-glutamate development and application. Biosensors 4, 381-391.
Yao, T., Kobayashi, N. & Wasa, T. 1990 Flow-injection analysis for L-glutamate using immobilized L-glutamate oxidase: comparison of an enzyme reactor and enzyme electrode. Analytica Chimica Acta 231, 121-124.
Yochida, S., Kanno, H. & Watanabe, T. 1995 Glutamate sensors carrying glutamate oxidase/peroxidase bienzyme system on Tin oxide electrode. Analytical Sciences 11, 251-256.