Polarity effect in commercial ionization chambers used in photon beams with small fields

Radiological Physics and Technology - Tập 2 Số 1 - Trang 97-103 - 2009
Shimono, Tetsunori1, Koshida, Kichiro2, Nambu, Hidekazu3, Matsubara, Kosuke2, Takahashi, Hiroshi1, Okuda, Hiroshi1
1Department of Radiology, Hoshigaoka Koseinenkin Hospital, Hirakata, Japan
2Department of Quantum Medical Technology, Kanazawa University Graduate School of Medical Sciences, Kanazawa, Japan
3Department of Radiology, Nara Hospital Kinki University Medical School, Ikoma, Nara, Japan

Tóm tắt

Ionization chambers are the instruments of choice for use in photon dosimetry. Ionization chambers together with radiographic films represent the best detectors for measurement of dose distribution for a quality assurance (QA) program in intensity-modulated radiotheraphy (IMRT). The polarity effect was investigated for seven different commercially available ionization chambers. This study concentrated on measuring the dependence of the polarity effect at various energies, and for various field size, ionization chamber, and electrometer combinations. Of the seven chambers, CC01, PTW23323, and PTW31006 had the largest polarity effect for small field sizes. The materials of the central electrode of these three chambers were steel or air-equivalent plastic C-552. The magnitude of the polarity effect was shown to be strongly dependent on the material of the collecting electrode. This polarity effect dependence was observed for the ionization chambers and small field sizes studied.

Tài liệu tham khảo

citation_journal_title=Med Phys; citation_title=On the beam quality specification of high-energy photons for radiotherapy dosimetry; citation_author=P Andreo; citation_volume=27; citation_publication_date=2000; citation_pages=434-44; citation_doi=10.1118/1.598892; citation_id=CR1 citation_journal_title=Med Phys; citation_title=Use of a new type of radiochromic firm, a new parallel-plate micro-chambers, MOSFETs and TLD 800 microcubes in the dosimetry of small beams; citation_author=P Francescon, S Cora, C Cavedon; citation_volume=25; citation_publication_date=1998; citation_pages=503-11; citation_doi=10.1118/1.598227; citation_id=CR2 citation_journal_title=Phys Med Biol; citation_title=The value of the PinPoint ion chamber for characterization of small field segments use in intensity-modulated radiotherapy; citation_author=C Martens, DC Watger, DW Neve; citation_volume=45; citation_publication_date=2000; citation_pages=2519-30; citation_doi=10.1088/0031-9155/45/9/306; citation_id=CR3 citation_journal_title=Int J Radiat Oncol Biol Phys; citation_title=Phantoms for IMRT dose distribution measurement and treatment verification; citation_author=DA Low, RL Gerber, S Mutic, JA Purdy; citation_volume=40; citation_publication_date=1998; citation_pages=1231-5; citation_doi=10.1016/S0360-3016(97)00910-3; citation_id=CR4 citation_journal_title=Int J Radiat Oncol Biol Phys; citation_title=Quality assurance of serial tomotherapy for head and neck patient treatment; citation_author=DA Low, KS Chao, S Mutic, RL Gerber, CA Perez, JA Purdy; citation_volume=42; citation_publication_date=1998; citation_pages=681-92; citation_doi=10.1016/S0360-3016(98)00273-9; citation_id=CR5 citation_journal_title=Med Phys; citation_title=Guidance document on delivery, treatment planning, and clinical implementation of IMRT Report of the IMRT subcommittee of the AAPM radiation therapy committee; citation_author=X Ezzel; citation_volume=30; citation_publication_date=2003; citation_pages=2089-115; citation_doi=10.1118/1.1591194; citation_id=CR6 citation_journal_title=Med Phys; citation_title=Polarity effect for various ionization chambers with multiple irradiation conditions in electron beam; citation_author=H Aget, JC Rosenwald; citation_volume=18; citation_publication_date=1991; citation_pages=67-72; citation_doi=10.1118/1.596694; citation_id=CR7 citation_journal_title=Med Phys; citation_title=The polarity effect for commercially available plane-parallel ionization chambers; citation_author=BJ Gerbi, FM Khan; citation_volume=14; citation_publication_date=1987; citation_pages=210-5; citation_doi=10.1118/1.596072; citation_id=CR8 citation_journal_title=Med Phys; citation_title=Measurement of the replacement correction factor for parallel-plate chambers in electron fields; citation_author=CS Reft, F Kuchnir; citation_volume=18; citation_publication_date=1991; citation_pages=1237-43; citation_doi=10.1118/1.596740; citation_id=CR9 citation_journal_title=Acta Radiol Oncol; citation_title=Calibration and use of plane parallel ionization chambers for the determination of absorbed dose is electron beams; citation_author=LO Mattsson, KA Johansson, H Svensson; citation_volume=20; citation_publication_date=1981; citation_pages=385-99; citation_doi=10.3109/02841868109130228; citation_id=CR10 citation_journal_title=Med Phys; citation_title=Energy-dependent polarity correction factors for four commercial ionization chambers used in electron dosimetry; citation_author=JA Williams, SK Agarwal; citation_volume=24; citation_publication_date=1997; citation_pages=785-90; citation_doi=10.1118/1.598124; citation_id=CR11 citation_journal_title=Med Phys; citation_title=Polarity effect in plane-parallel ionization chambers using air or a dielectric liquid as ionization medium; citation_author=G Wickman, T Holmstrom; citation_volume=19; citation_publication_date=1992; citation_pages=637-40; citation_doi=10.1118/1.596934; citation_id=CR12 citation_journal_title=Med Phys; citation_title=Evaluations of two solid water parallel-plate chambers in high-energy photon and electron beams; citation_author=H Kubo; citation_volume=20; citation_publication_date=1993; citation_pages=341-5; citation_doi=10.1118/1.597074; citation_id=CR13 citation_journal_title=Med Phys; citation_title=The response characteristics of a newly designed plane-parallel ionization chamber in high-energy photon and electron beams; citation_author=BJ Gerbi; citation_volume=20; citation_publication_date=1993; citation_pages=1411-5; citation_doi=10.1118/1.597105; citation_id=CR14 citation_journal_title=Med Phys; citation_title=Clinical electron beam dosimetry: report of AAPM radiation therapy committee task group No. 25; citation_author=; citation_volume=18; citation_publication_date=1991; citation_pages=73-109; citation_id=CR15 citation_journal_title=Phys Med Biol; citation_title=Pre-irradiation effects on ionization chambers used in radiation therapy; citation_author=JP McCaffrey, B Downton, H Shen, D Niven, M McEwen; citation_volume=50; citation_publication_date=2005; citation_pages=121-33; citation_doi=10.1088/0031-9155/50/13/N01; citation_id=CR16 citation_journal_title=Phys Med Biol; citation_title=Distortion of the electric field in an ionization chamber due to a difference in potential between guard electrode and collector; citation_author=JW Boag; citation_volume=9; citation_publication_date=1963; citation_pages=25-32; citation_doi=10.1088/0031-9155/9/1/302; citation_id=CR17 citation_journal_title=Phys Med Biol; citation_title=Numerical solutions of differential equations of a cylindrical ionization chamber; citation_author=D Novkovic, Z Milosevic, K Subotic, S Manic-Kudra; citation_volume=41; citation_publication_date=1996; citation_pages=725-41; citation_doi=10.1088/0031-9155/41/4/009; citation_id=CR18 citation_journal_title=Med Phys; citation_title=Monte Carlo study of a Cyberknife stereotactic radiosurgery system; citation_author=F Araki; citation_volume=33; citation_publication_date=2006; citation_pages=2955-63; citation_doi=10.1118/1.2219774; citation_id=CR19 citation_journal_title=Med Phys; citation_title=A new approach to firm dosimetry for high energy photon beams: lateral scatter filtering; citation_author=SE Burch, KJ Kearfott, JH Trueblood, WC Sheils, JI Yeo, CKC Wang; citation_volume=24; citation_publication_date=1997; citation_pages=775-83; citation_doi=10.1118/1.597999; citation_id=CR20 citation_journal_title=Med Phys; citation_title=Letter to the editor: how much does firm sensitivity increase at depth for larger field sizes?; citation_author=JR Sykes, HV James, PC Williams; citation_volume=26; citation_publication_date=1999; citation_pages=329-30; citation_doi=10.1118/1.598520; citation_id=CR21