Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement

Journal of Arthroplasty - Tập 14 Số 5 - Trang 616-627 - 1999
Avram A. Edidin1, Lisa A. Pruitt2, Charles W. Jewett2, Deborah J. Crane2, Daniel K. Roberts3, Steven M. Kurtz4
1Stryker Howmedica Osteonics, Allendale, New Jersey, USA
2Department of Mechanical Engineering, University of California at Berkeley, Berkeley, California, USA
3Exponent Failure Analysis Associates, Menlo Park, California, USA
4Exponent Failure Analysis Associates, Philadelphia, Pennsylvania, USA

Tóm tắt

Từ khóa


Tài liệu tham khảo

Wang, 1997, Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene, Wear, 203, 230, 10.1016/S0043-1648(96)07362-0

Jasty, 1997, Wear of polyethylene acetabular components in total hip arthroplasty: an analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations, J Bone Joint Surg Am, 79, 349, 10.2106/00004623-199703000-00005

Kurtz, 1997, Validation of a small punch testing technique to characterize the mechanical behavior of ultra-high molecular weight polyethylene, Biomaterials, 18, 1659, 10.1016/S0142-9612(97)00124-5

Kurtz, 1999, A miniature-specimen mechanical testing technique scaled to the articulating surface of polyethylene components for total joint arthroplasty, J Biomed Mater Res (Appl Biomater), 48, 75, 10.1002/(SICI)1097-4636(1999)48:1<75::AID-JBM13>3.0.CO;2-H

White, 1996, Effects of sterilization on wear in total knee arthroplasty, Clin Orthop, 331, 164, 10.1097/00003086-199610000-00023

Sutula, 1995, Impact of gamma sterilization on clinical performance of polyethylene in the hip, Clin Orthop, 319, 28

Collier, 1996, Impact of gamma sterilization on clinical performance of polyethylene in the knee, J Arthroplasty, 11, 377, 10.1016/S0883-5403(96)80026-X

Foulds, 1995, Fracture toughness by small punch testing, J Testing Eval, 23, 3, 10.1520/JTE10392J

Butler, 1998, Time resolved simulataneous small- and wide-angle X-ray scattering during polyethylene deformation: II. Cold drawing of linear polyethylene, Polymer, 39, 39, 10.1016/S0032-3861(97)00226-7

Bellare, 1996, Morphology of rod stock and compression-moulded sheets of ultra-high-molecular-weight polyethylene used in orthopaedic implants, Biomaterials, 17, 2325, 10.1016/S0142-9612(96)00086-5

Pruitt, 1998, Factors affecting the near-threshold fatigue behavior of surgical grade ultra high molecular weight polyethylene, Polymer, 39, 1545, 10.1016/S0032-3861(97)00448-5

Goldman, 1996, The effects of gamma radiation sterilization and ageing on the structure and morphology of medical grade ultra-high molecular weight polyethylene, Polymer, 37, 2909, 10.1016/0032-3861(96)89386-4

Pooley, 1972, Friction and molecular structure: the behavior of some thermoplastics, 329, 251

Wang, 1995, Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups, J Biomed Mater Res, 29, 619, 10.1002/jbm.820290509

Wang, 1996, Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions, Biomaterials, 17, 865, 10.1016/0142-9612(96)83281-9

Wang, 1997, Wear mechanisms and wear testing of ultra-high molecular weight polyethylene in total joint replacements

McKellop, 1995, The origin of submicron polyethylene wear debris in total hip arthroplasty, Clin Orthop, 311, 3

Cooper, 1993, Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene, Wear, 162–164, 378, 10.1016/0043-1648(93)90521-M

Wang, 1996, Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint prostheses, 210, 141

Bragdon, 1996, The importance of multidirectional motion on the wear of polyethylene, 210, 157

Sauer, 1998, Predicting the clinical wear performance of orthopaedic bearing surfaces

McKellop, 1997, Effect of sterilization method and other modifications on the wear resistance of UHMWPE acetabular cups

Jasty, 1997, Marked improvement in the wear resistance of a new form of UHMWPE in a physiologic hip simulator

Wang, 1997, Effect of radiation dosage on the wear of stabilized UHMWPE evaluated by kip and knee joint simulators

Sawyer, 1987

Streicher, 1988, Ionizing irradiation for sterilization and modification of high molecular weight polyethylenes, 10, 221

Rose, 1984, Radiation sterilization and the wear rate of polyethylene, J Orthop Res, 2, 393, 10.1002/jor.1100020412

Rimnac, 1994, Post-irradiation aging of ultra-high molecular weight polyethylene, J Bone Joint Surg Am, 76, 1052, 10.2106/00004623-199407000-00014

Kurtz, 1997, Degradation rate of ultra-high molecular weight polyethylene, J Orthop Res, 15, 57, 10.1002/jor.1100150109

Bostrom, 1994, The natural history of ultra high molecular weight polyethylene, Clin Orthop, 309, 20

Kurtz, 1996, Exponential model for the tensile true stress-strain behavior of as-irradiated and oxidatively degraded ultra high molecular weight polyethylene, J Orthop Res, 14, 755, 10.1002/jor.1100140512

Greer, 1998, The hip simulator wear of gamma-vacuum, gamma-air, and ethylene oxide sterilized UHMWPE following a severe oxidative challenge

Muratoglu, 1998, A novel technique to measure the cross-link density of irradiated UHMWPE

Lin, 1994, Review: structure and plastic deformation of polyethylene, J Mater Sci, 29, 294, 10.1007/BF01162485

Bowden, 1974, Review: deformation mechanisms in crystalline polymers, J Mater Sci, 9, 2034, 10.1007/BF00540553

Keller, 1971, Identification of structural processes in deformation of oriented polyethylene, J Mater Sci, 6, 453, 10.1007/BF00550302

G'Sell, 1994, Evolution of microstructure in semi-crystalline polymers under large plastic deformations, Mater Sci Eng, 175, 183, 10.1016/0921-5093(94)91058-8

Gul, 1997, Improved UHMWPE for use in total joint replacement