Physico-chemical considerations of titanium as a biomaterial

Clinical Materials - Tập 9 - Trang 115-134 - 1992
Pentti Tengvall1, Ingemar Lundström1
1Linköping University, Department of Physics and Measurement Technology, S-581 83 Linköping, Sweden

Tài liệu tham khảo

Bothe, 1940, Reaction of bone to multiple metallic implants, Surg. Gynecol. Obstet., 71, 598 Leventhal, 1951, Titanium, a metal for surgery, J. Bone Joint Surg., 33A, 473, 10.2106/00004623-195133020-00021 Bränemark, 1969, Intraosseous anchorage of dental prostheses. I Experimental studies, Scand. J. Plast. Reconstr. Surg., 3, 81, 10.3109/02844316909036699 Brånemark, 1977, Osseointegrated implants in the treatment of edentulous jaw. Experience from a 10-year period, Scand. J. Reconstr. Surg., 1 Williams, 1974, A combined metallurgical and histological study of tissue-prosthesis interactions in orthopaedic patients, 5, 1 Meachim, 1973, Changes in nonosseous tissue adjacent to titanium implants, J. Biomed. Mater. Res., 65B, 555, 10.1002/jbm.820070607 Thomsen, 1986, Implants in the abdominal wall of the rat, Scand. J. Reconst. Surg., 20, 173, 10.3109/02844318609006316 Holgers, Clinical and histological evaluation of adverse effects of percutaneous bone-anchored titanium implants. Program and abstract book, 13 Rae, 1981, Cell biochemistry in relation to the inflammatory response to foreign materials, vol. 1, 159 Meachim, 1981, The tissue response at implant sites, vol. l, 107 Lalor, 1990, Studies of the cellular response to TiAlV metal alloy implants in experimental animals. Abstract book, 298 Blunn, 1990, Reaction of tissues to titanium wear debris. Program and abstract book, 13 Kasemo, 1986, Surface science aspects on inorganic biomaterials, CRC Critical Reviews in Biocompatibility, 335 Babior, 1973, Biological defense mechanisms: the production by leucocytes of superoxide: a potential bactericidal agent, J. Clin. Invest., 51, 741, 10.1172/JCI107236 Klebanoff, 1988, Products of oxygen metabolism, 391 Deby, 1984, Superoxide production in white cells in inflammation, 33 Halliwell, 1984, Oxygen toxicity, oxygen radicals, transition metals and disease, Biochem. J., 219, 1, 10.1042/bj2190001 Bielski, 1985, Fast kinetic studies of dioxygen-derived species and their metal complexes, B 311, 473 Bors, 1980, The nature of intermediates during biological oxygen activation, 1 Goldstein, 1986, The role and mechanism of metal ions and their complexes in enhancing damage in biological systems or in protecting these systems from the toxicity of O2−, J. Free Radicals in Biology & Medicine, 2, 3, 10.1016/0748-5514(86)90117-0 Czapski, 1983, The sensitization of the toxicity of superoxide and vitamin C by copper and iron: a site specific mechanism, 111 Vroman, 1987, Why plasma proteins interact at interfaces, 154 Horbett, 1987, Proteins at interfaces current issues and future prospects, 1 Moncada, 1989, Biosynthesis of nitric oxide from l-arginine, a pathway for the regulation of cell function and communication, Biochem. Pharm., 38, 1709, 10.1016/0006-2952(89)90403-6 Collier, 1989, Second messenger role for NO widens to nervous and immune systems, Trends Pharmacol. Sci., 10, 427, 10.1016/S0165-6147(89)80001-X Pourbaix, 1966, 80 Pourbaix, 1966, 213 Williams, 1976, Corrosion of implant materials, Ann. Rev. Mater. Sci., 6, 237, 10.1146/annurev.ms.06.080176.001321 Zitter, 1987, The electrochemical behaviour of metallic implant materials as an indicator of their biocompatibility, J. Biomed. Mater. Res., 21, 881, 10.1002/jbm.820210705 Breme, 1989, Titanium and its alloys biomaterials of preference, Mem. Etud. Sci. Rev. Metall., 86, 625 Xiangrong, 1989, Study on galvanic corrosion of titanium alloys in seawater, Mem. Etud. Sci. Rev. Metall., 86, 667 Black, 1984, Systemic effects of Biomaterials, Biomaterials, 5, 11, 10.1016/0142-9612(84)90061-9 Steinemann, 1980, Titanium alloys as metallic biomaterials, vol. 2, 1327 Baes, 1976, The Hydrolysis of Cations, 147 Brown, 1980, Electrochemical corrosion in saline and serum, J. Biomed. Mater. Res., 14, 173, 10.1002/jbm.820140208 Clark, 1982, The effects of proteins on metallic corrosion, J. Biomed. Mater. Res., 16, 125, 10.1002/jbm.820160205 Steinemann, 1985, 5. Vortragsreihe des DVM-Arbetskreises Implantate, Deutscher Verband für Materialpriifung e.V., 63 Steinemann, 1988, Titanium alloys for surgical implants—biocompatibility from physicochemical principles, 535 Laing, 1967, Tissue reaction in rabbit muscle exposed to metallic implants, J. Biomed. Mater. Res., 1, 135, 10.1002/jbm.820010113 Sundgren, 1986, Auger electronspectroscopic studies of the interface between human tissue and implants of titanium and stainless steel, J. Colloid Int. Sci., 110, 9, 10.1016/0021-9797(86)90348-6 Tengvall, 1987, Free radicals, oxidation of metal implants and biocompatibility, 39 Bruneel, 1988, In-vitro simulation of biocompatibility of titanium, J. Biomed. Mater Res., 22, 203, 10.1002/jbm.820220305 Grootveld, 1990, Speciation of implant-derived titanium-(III)/(IV) ions in samples obtained from patients with joint pros theses containing titanium-aluminium-vanadium. Abstract book, 304 Tengvall, 1989, Titanium-hydrogen peroxide interaction: model studies of the influence of the inflammatory response on titanium implants, Biomaterials, 10, 166, 10.1016/0142-9612(89)90019-7 Cornell, 1975, A titrimetric and electrophoretic investigation of the pzc and the iep of pigment ruble, J. Colloid Interface Sci., 53, 6, 10.1016/0021-9797(75)90028-4 Boehm, 1971, Acidic and basic properties of hydroxylated metal oxide surfaces, Disc. Faraday Soc., 52, 264, 10.1039/df9715200264 Parks, 1965, The isoclectric points of solid oxides, solid hydroxides, and aqueous hydroxc, complex systems, Chem. Rev., 65, 177, 10.1021/cr60234a002 Schindler, 1972, Kolloid-Z.u.Z, Polymere, 250, 759, 10.1007/BF01498568 Gold, 1989, XPS study of amino acid adsorption to titanium surfaces, Helv. Phys. Acta., 62, 246 Ray, 1974, The zero point of charge of chromic oxide-solution interface, Ind. J. Chem., 12, 75 Schott, 1977, Relationship between zero point of charge and solubility product for hydroxides of polyvalent cations, J. Pharm. Sci., 66, 1548, 10.1002/jps.2600661111 Pourbaix, 1984, Electrochemical corrosion of metallic biomaterials, Biomaterials, 5, 122, 10.1016/0142-9612(84)90046-2 Steinemann, 1980, Titanium alloys as metallic biomaterials, vol. 2, 1327 Zetner, 1980, Tissue and cell reactions in vivo and in vitro to different metals for dental implants, 15 Landolt-Börnstein, 1959, Zahlenwerte and Funktionen aus Physck-Chemie-Astronomie-Geophysik-Technik, 11 band, 22 Landolt-Börnstein, 1959, Zahlenwerte and Funktionen aus Physck-Chemie-Astronomie-Geophysik-Technik, II band, 449 Norde, 1979, Thermodynamics of protein adsorption, theory with special reference to the adsorption of human plasma albumin and bovine pancreas ribo nuclease at polystyrene surfaces, J. Colloid Interface Sci., 71, 350, 10.1016/0021-9797(79)90245-5 Törnkvist, 1990 Albrektsson, 1983, The interface zone of inorganic implants in vivo : titanium implants in bone, Ann. Biomed. Eng., 11, 1, 10.1007/BF02363944 Parsegian, 1983, Molecular forces governing tight contact between cellular surfaces and substrates, J. Prosth. Dent., 49, 838, 10.1016/0022-3913(83)90360-8 Lundstrdm, 1983, Surface Physics and Biological Phenomena, Physica Scripta, T4, 5, 10.1088/0031-8949/1983/T4/001 Donath, 1989, A comparison of tissue-implant interface on osseous integrated titanium and hydroxylapatite coated titanium dental implants, 193 Singh, 1978, Introduction: interconversion of singlet oxygen and related species, Photochem. Photobiol., 28, 429, 10.1111/j.1751-1097.1978.tb06942.x Halliwell, 1989, Free Radicals in Biology and Medicine, 1 McCord, 1974, Free radicals in inflammation: protection of synovial fluid by superoxide dismutase, Science, 185, 529, 10.1126/science.185.4150.529 Fee, J.A. & Valentine, J.S., Chemical and physical properties of superoxide. In Superoxide and Superoxide Dismutases, ed. A.M. Michelson, J.M. McCord & I. Fridovich. Academic Press, New York, NY, pp. 19–57. Oshino, 1973, The role of H2O2 generation in perfused rat liver and the reaction of catalase compound I and hydrogen donors, Arch. Biochem. Biophys., 154, 117, 10.1016/0003-9861(73)90040-4 Hennig, 1988, Lipid peroxidation and endothelial cell injury: implications in atherosclerosis, Free Radicals in Biol. & Med., 4, 96, 10.1016/0891-5849(88)90070-6 Chatterjee, 1988, Liposomes as membrane model for study of lipid peroxidation, Free Radicals in Biol. & Med., 4, 51, 10.1016/0891-5849(88)90011-1 Freeman, 1982, Biology of disease: free radicals and tissue injury, Lab. Invest., 47, 412 Greenwald, 1980, Effect of oxygen-derived free radicals on hyaluronic acid, Arth. Reum., 23, 455, 10.1002/art.1780230408 Mühlebach, 1970, The peroxo complexes of titanium, Inorg. Chem., 9, 2381, 10.1021/ic50093a001 Schwarzenbach, 1970, The structure of a chelated dinuclear peroxytitanium(IV), Inorg. Chem, 9, 2391, 10.1021/ic50093a002 Tengvall, 1989, Titanium gel made from metallic titanium and hydrogen peroxide, J. Colloid Interface Sci., 130, 405, 10.1016/0021-9797(89)90117-3 Tengvall, 1990, Degradation of dried Ti-peroxy gels made from metallic titanium and hydrogen peroxide, J. Colloid Interface Sci., 139, 575, 10.1016/0021-9797(90)90131-7 Tengvall, 1991, Stable titanium- superoxide radicals in aqueous Tiperoxy gels and Ti-peroxide solutions, J. Colloid Interface Sci., 143, 589, 10.1016/0021-9797(91)90291-F Berdnikov, 1978, Reactivity of coordinated O2− ion-radicals towards oneelectron reductants, React. Kinet. Catal, Lett., 9, 275, 10.1007/BF02070499 Tengvall, 1990, Bactericidal properties of a titanium-peroxy gel obtained from metallic titanium and hydrogen peroxide, J. Biomed. Mater. Res., 24, 319, 10.1002/jbm.820240305 Orhanovic, 1967, Kinetic studies of the reactions of peroxy compounds of chromium(VI), vanadium(V) and titanium(IV) in acidic media, J. Am. Chem. Soc., 89, 278, 10.1021/ja00978a019 Merkulov, 1979, Decomposition mechanism of O2− complexes with Ti(IV) ions, Koord. Khim., 5, 177 Bjursten, L. M., Tengvall, P., Ericson, L. E., Gretzer, C. & Lundström, I., The anti-inflammatory effects of a titaniumperoxy gel on polymorphonuclear granulocytes. Agents and Action, in press. Hanawa, 1990, Titanium and its oxide film: a substratum for formation of apatite Ducheyne, 1990, Titanium: immersion induced surface chemistry changes and the relationship to passive dissolution and bioactivity Blumenthal, 1989, Inhibition of apatite formation by titanium and vanadium ions, J. Biomed. Mater. Res., 23, 13, 10.1002/jbm.820231305 Johnsson, 1990, Kinetics of mineralization, demineralization and transformation of calcium phosphates at mineral and protein surfaces Chester, 1961, Electron spin resonance in semiconducting rutile, J. Appl. Phys., 32, 2233, 10.1063/1.1777049 Bogomolov, 1968, Electron paramagnetic resonance of partially reduced rutile, Sov. Phys.-Sol. St., 9, 2647 Meriaudeau, 1970, Angular overlap treatment and electron spin resonance of titanium(III) in anatase, Chem. Phys. Lett., 5, 131, 10.1016/0009-2614(70)80022-7 Mizushima, 1979, Impurity levels of iron-group ions in TiO2(II), J. Phys. Chem. Solids, 40, 1129, 10.1016/0022-3697(79)90148-3 Catton, 1980, Detection of paramagnetic intermediates in the reaction of aqueous titanium(III) complexes with oxygen, J. C. S. Chem. Comm., 18, 836 Skupinska, 1981, ESR investigation of Ti(3+) compounds supported on inorganic gels, React. Kinet. Catal. Lett., 16, 297, 10.1007/BF02065477 Gadzhieva, 1982, Characteristic features of the state of d1 ions in the sites and interstitial positions of the rutile structure from EPR data, Zh. Strukt. Kh., 23, 43 Amorelli, 1987, An electron spin resonance study of rutile and anatase titanium dioxide polycrystalline powders treated with transition-metal ions, J. Chem. Soc. Faraday Trans. I, 83, 3541, 10.1039/f19878303541 Tachikawa, 1990, Hydration structure of titanium(III) ion. ESR and electron spin-echo study, J. Am. Chem. Soc., 112, 977, 10.1021/ja00159a012 Grätzel, 1990, Electron paramagnetic resonance studies of doped TiO2 colloids, J. Phys. Chem., 94, 2566, 10.1021/j100369a064 Ookubo, 1990, ESR, XRD, and DRS studies of paramagnetic Ti3+ ions in a colloidal solid of titanium oxide prepared by the hydrolysis of TiCl3, Langmuir, 6, 206, 10.1021/la00091a033 Goodenough, 1971, Metallic oxides, vol. 5, 344 Criado, 1989, Study of mechanochemical phase transformation of TiO2 by EPR. Effect of phosphate, Solid State Ionics, 32/33, 461, 10.1016/0167-2738(89)90256-7 Grant, 1980, The adsorption of human serum albumin and gamma-globulin on hydrophobic and hydrophilic surfaces, Vol. 12B, 827 MacRitchie, 1972, The adsorption of proteins at the solid/liquid interface, J. Colloid Interface Sci., 38, 484, 10.1016/0021-9797(72)90264-0 Sawyer, 1976, Electrokinetic processes on natural and artificial blood vessels, 143 Morrisey, 1977, The adsorption and conformation of plasma proteins: a physical approach, Ann. N.Y. Acad. Sci., 283, 50, 10.1111/j.1749-6632.1977.tb41752.x Ivarsson, 1986, Physical characterization of protein adsorption on metal and metaloxide surfaces, 1 Law, 1988, 1 Chenoweth, 1987, Complement activation in. extracorporeal circuits, 516, 306 Andrade, 1991, Vroman effects; techniques, and philosophies, J. Biomater. Sci., 2, 161, 10.1080/09205063.1991.9756657 Elwing, 1991, ‘Lens on surface’: a versatile method for the investigation of plasma protein exchange reactions on solid surfaces, J. Biomater. Sci., 3, 7, 10.1163/156856292X00042 1983, 408, 521 Wälivaara, B., Lundstrmm, I. & Tengvall, P., An in vitro study of H2O2-treated titanium surfaces in contact with blood plasma and a simulated body fluid, submitted. Adell, 1981, Osseointegrated implant in the treatment of edentulousness. A 15 year follow-up study, J. Oral. Surg., 6, 387, 10.1016/S0300-9785(81)80077-4 Albrektson, 1985, Interface analysis of titanium and zirconium bone implants, Biomaterials, 6, 97, 10.1016/0142-9612(85)90070-5 Röstlund, 1989, Wear of ion implanted pure titanium against UHMWPE, Biomaterials, 10, 176, 10.1016/0142-9612(89)90020-3 Dearnaley, 1986, Ion-implantation and ion assisted coating of metals, Vacuum, 36, 807, 10.1016/0042-207X(86)90116-8 van Noort, 1987, Titanium: the implant material of today, J. Mat. Sci., 22, 3801, 10.1007/BF01133326 Perry, 1987, Ion implantation of titanium alloys for biomaterial and other applications, Surf: Eng., 3, 154, 10.1179/sur.1987.3.2.154 Kovacs, 1990, Effect of ion implantation on the release of implant metal bearing surfaces, vol. XIII, 127 Röstlund, 1990, Difference in tissue response to nitrogen-ionimplanted titanium and c.p. titanium in the abdominal wall of the rat, J. Biomed. Mater. Res., 24, 847, 10.1002/jbm.820240705 Jarcho, 1977, Tissue, cellular and subcellular events at a bone-ceramic hydroxyapatite surface, J. Bioeng., 1, 79 Madden, 1978, The rate of bond formation of bioglass and dense hydroxyapatite implants in rats, 141 Lacefield, 1988, Hydroxyapatite coatings, 523, 72 Ducheyne, 1980, The effect of hydroxyapatite impregnation on skeletal bonding of porous implants, J. Biomed. Mater. Res., 14, 225, 10.1002/jbm.820140305 Ducheyne, 1990, Calcium phosphate ceramic coatings on porous titanium: effect of structure and composition on electrophoretic deposition, vacuum sintering and in-vitro dissolution, Biomaterials, 11, 244, 10.1016/0142-9612(90)90005-B de Groot, 1981, Degradable ceramics, vol 1, 199 Thomas, 1987, The effect of surface macrotexture and hydroxyapatite coating on the mechanical strengths and histologic profiles of titanium implant materials, J. Biomed. Mater. Res., 21, 1395, 10.1002/jbm.820211205 Spivak, 1990, A new canine model to evaluate the biological response of intramedullary bone to implant materials and surfaces, J. Biomed. Mater. Res., 24, 1121, 10.1002/jbm.820240902 de Groot, 1987, Plasma sprayed coatings of hydroxyapatite, J. Biomed. Mater, Res., 21, 1375, 10.1002/jbm.820211203 Chae, 1988, Efficacy of plasma-sprayed tricalcium phosphate in enhancing the fixation of smooth titanium intramedullary rods, 523, 81 Oonishi, 1989, The effect of hydroxyapatite coating on bone growth into porous titanium implants, J. Bone & Joint Surg., 71B, 213, 10.1302/0301-620X.71B2.2925737 Roberts, 1984, Osseous adaptation to continuous loading of rigid endosseous implants, Am. J. Orthod., 86, 95, 10.1016/0002-9416(84)90301-4 Williams, 1981, Toxicology of implanted metals, vol. 2, 46