Photon-specific absorbed fraction estimates in stylized ORNL and voxelized ICRP adult male phantoms using a new developed Geant4-based code “DoseCalcs”: a validation study

Radiological Physics and Technology - Tập 15 Số 4 - Trang 323-339 - 2022
T. El Ghalbzouri1, T. El Bardouni2, Jaafar El Bakkali2,3, Hicham Satti2, A. Arectout2, I. Berriban2, A Nouayti2, Randa Yerrou2
1ERSN Laboratory, Physics Department, Faculty of Sciences, University Abdelmalek Essaadi, Tetouan, Morocco. [email protected].
2ERSN Laboratory, Physics Department, Faculty of Sciences, University Abdelmalek Essaadi, Tetouan, Morocco
3Nuclear Medicine Department, Military Hospital Mohammed V, Rabat, Morocco

Tóm tắt

Từ khóa


Tài liệu tham khảo

Zaidi H. Recent developments and future trends in nuclear medicine instrumentation. Z Med Phys. 2006;16(1):5–17.

Huang B, Law MW-M, Khong P-L. Whole-body PET/CT scanning estimation of radiation dose and cancer risk. Radiology. 2009;251:166–74.

Glatting G, Lassmann M. Nuclear medicine dosimetry: quantitative imaging and dose calculations. Z Med Phys. 2011;21:246–7.

Endo M. History of medical physics. Radiol Phys Technol. 2021;14:345–57.

Dunn WL, Shultis JK. Exploring Monte Carlo methods. Amsterdam: Elsevier; 2011.

...Agostinelli S, Allison J, Amako K, Apostolakis J, Araujo H, Arce P, Asai M, Axen D, Banerjee S, Barrand G, Behner F, Bellagamba L, Boudreau J, Broglia L, Brunengo A, Burkhardt H, Chauvie S, Chuma J, Chytracek R, Cooperman G, Cosmo G, Degtyarenko P, Dell’Acqua A, Depaola G, Dietrich D, Enami R, Feliciello A, Ferguson C, Fesefeldt H, Folger G, Foppiano F, Forti A, Garelli S, Giani S, Giannitrapani R, Gibin D, Gómez Cadenas JJ, González I, Gracia Abril G, Greeniaus G, Greiner W, Grichine V, Grossheim A, Guatelli S, Gumplinger P, Hamatsu R, Hashimoto K, Hasui H, Heikkinen A, Howard A, Ivanchenko V, Johnson A, Jones FW, Kallenbach J, Kanaya N, Kawabata M, Kawabata Y, Kawaguti M, Kelner S, Kent P, Kimura A, Kodama T, Kokoulin R, Kossov M, Kurashige H, Lamanna E, Lampén T, Lara V, Lefebure V, Lei F, Liendl M, Lockman W, Longo F, Magni S, Maire M, Medernach E, Minamimoto K, de Mora Freitas P, Morita Y, Murakami K, Nagamatu M, Nartallo R, Nieminen P, Nishimura T, Ohtsubo K, Okamura M, O’Neale S, Oohata Y, Paech K, Perl J, Pfeiffer A, Pia MG, Ranjard F, Rybin A, Sadilov S, DiSalvo E, Santin G, Sasaki T, Savvas N, Sawada Y, Scherer S, Sei S, Sirotenko V, Smith D, Starkov N, Stoecker H, Sulkimo J, Takahata M, Tanaka S, Tcherniaev E, Safai–Tehrani E, Tropeano M, Truscott P, Uno H, Urban L, Urban P, Verderi M, Walkden A, Wander W, Weber H, Wellisch JP, Wenaus T, Williams DC, Wright D, Yamada T, Yoshida H, Zschiesche D. Geant4—a simulation toolkit. Nucl Instrum Methods Phys Res A. 2003;506:250–303.

...Jan S, Santin G, Strul D, Staelens S, Assié K, Autret D, Avner S, Barbier R, Bardiès M, Bloomfield PM, Brasse D, Breton V, Bruyndonckx P, Buvat I, Chatziioannou AF, Choi Y, Chung YH, Comtat C, Donnarieix D, Ferrer L, Glick SJ, Groiselle CJ, Guez D, Honore PF, Kerhoas-Cavata S, Kirov AS, Kohli V, Koole M, Krieguer M, van der Laan DJ, Lamare F, Largeron G, Lartizien C, Lazaro D, Maas MC, Maigne L, Mayet F, Melot F, Merheb C, Pennacchio E, Perez J, Pietrzyk U, Rannou FR, Rey M, Schaart DR, Schmidtlein CR, Simon L, Song TY, Vieira JM, Visvikis D, Van de Walle R, Wieërs E, Morel C. GATE: a simulation toolkit for PET and SPECT. Phys Med Biol. 2004;49:4543–61.

Pietrzyk U, Zakhnini A, Axer M, Sauerzapf S, Benoit D, Gaens M. EduGATE—basic examples for educative purpose using the GATE simulation platform. Z Med Phys. 2013;23:65–70.

Werner CJ, Bull JS, Solomon CJ, Brown FB, McKinney GW, Rising ME, Dixon DA, Martz RL, Hughes HG, Cox LJ, Zukaitis AJ, Armstrong JC, Forster RA, Casswell L. “MCNP version 6.2. release notes,” tech. rep., 2018.

Bakkali JE, Doudouh A, Bardouni TE. InterDosi simulations of photon- and alpha-specific absorbed fractions in the Zubal voxelized phantom. Appl Radiat Isot. 2021;176: 109838.

Ocampo JC, Puerta JA, Morales J. Evaluation of specific absorbed fractions from the internal photon sources in the ICRP reference male phantom. Radiat Prot Dosim. 2013;157:133–41.

Schwarz BC, Godwin WJ, Wayson MB, Dewji SA, Jokisch DW, Lee C, Bolch WE. Specific absorbed fractions for a revised series of UF/NCI pediatric reference phantoms: internal photon sources. Phys Med Biol. 2021;66: 035006.

Schwarz BC, Godwin WJ, Wayson MB, Dewji SA, Jokisch DW, Lee C, Bolch WE. Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources. Phys Med Biol. 2021;66: 035006.

Chytracek R, Mccormick J, Pokorski W, Santin G. Geometry description markup language for physics simulation and analysis applications. IEEE Trans Nucl Sci. 2006;53:2892–6.

Stroud I, Xirouchakis PC. STL and extensions. Adv Eng Softw. 2000;31:83–95.

Constantin M, Constantin DE, Keall PJ, Narula A, Svatos M, Perl J. Linking computer-aided design (CAD) to geant4-based monte Carlo simulations for precise implementation of the complex treatment head geometries. Phys Med Biol. 2010;55:N211-20.

Poole CM, Cornelius I, Trapp JV, Langton CM. A CAD interface for GEANT4. Australas Phys Eng Sci Med. 2012;35:329–34.

Snir M, Gropp W, Otto S, Huss-Lederman S, Dongarra J, Walker D. MPI—complete reference: the MPI core, vol. 1. London: MIT Press; 1998.

Ahn S, Apostolakis J, Asai M, Brandt D, Cooperman G, Cosmo G, Dotti A, Dong X, Yung Jun S, Nowak A. GEANT4-MT : bringing multi-threading into GEANT4 production. In: D. Caruge, C. Calvin, C. M. Diop, F. Malvagi, and J.-C. Trama, (eds) SNA + MC 2013—Joint International Conference on Supercomputing in Nuclear Applications + Monte Carlo, (Les Ulis, France), EDP Sciences, 2014.

Brun R, Rademakers F. ROOT—anobject-oriented data analysis framework. Nucl Instrum Methods Phys Res A. 1997;389:81–6.

Kim CH, Yeom YS, Petoussi-Henss N, Zankl M, Bolch WE, Lee C, Choi C, Nguyen TT, Eckerman K, Kim HS, Han MC, Qiu R, Chung BS, Han H, Shin B. ICRP publication 145: adult mesh type reference computational phantoms. Ann ICRP. 2020;49:13–201.

Guatelli S, Mascialino B, Pia MG, Pokorski W. Geant4 anthropomorphic phantoms. In: 2006 IEEE Nuclear Science Symposium Conference Record, IEEE. 2006.

Cristy M, Eckerman K. Specific absorbed fractions of energy at various ages from internal photon sources: 1 Methods. Tech. rep., Oak Ridge National Laboratory, TN (USA), 1987.

Zankl M. Adult male and female reference computational phantoms (ICRP publication 110). Jpn J Health Phys. 2010;45(4):357–69.

Chauvin M, Mathieu G, Camarasu-Pop S, Bonnet A, Bardies M, Perseil I. Enabling large scale data production for OpenDose with GATE on the EGI infrastructure. In: 2019 19th IEEE/ACM International Symposium on Cluster, Cloud, and Grid Computing (CCGRID), IEEE, May 2019.

...Arce P, Bolst D, Bordage MC, Brown JMC, Cirrone P, Cortés-Giraldo MA, Cutajar D, Cuttone G, Desorgher L, Dondero P, Dotti A, Faddegon B, Fedon C, Guatelli S, Incerti S, Ivanchenko V, Konstantinov D, Kyriakou I, Latyshev G, Le A, Mancini-Terracciano C, Maire M, Mantero A, Novak M, Omachi C, Pandola L, Perales A, Perrot Y, Petringa G, Quesada JM, Ramos-Méndez J, Romano F, Rosenfeld AB, Sarmiento LG, Sakata D, Sasaki T, Sechopoulos I, Simpson EC, Toshito T, Wright DH. Report on G4-Med, a geant4 benchmarking system for medical physics applications developed by geant4 medical simulation benchmarking group. Med Phys. 2021;48:19–56.

Cristy M, Eckerman K. Specific absorbed fractions of energy at various ages from internal photon sources: 7, adult males. 1987.

Chauvin M, Borys D, Botta F, Bzowski P, Dabin J, Denis-Bacelar AM, Desbrée A, Falzone N, Lee BQ, Mairani A, Malaroda A, Mathieu G, McKay E, Mora-Ramirez E, Robinson AP, Sarrut D, Struelens L, Gil AV, Bardiès M. OpenDose: open-access resource for nuclear medicine dosimetry. J Nucl Med. 2020;61:1514–9.

Parach AA, Rajabi H, Askari MA. Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code. Radiat Environ Biophys. 2011;50:441–50.

Snyder WS. Mird pamphlet no. 5: estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. J Nucl Med. 1969;10:1.

...Jan S, Santin G, Strul D, Staelens S, Assié K, Autret D, Avner S, Barbier R, Bardiès M, Bloomfield PM, Brasse D, Breton V, Bruyndonckx P, Buvat I, Chatziioannou AF, Choi Y, Chung YH, Comtat C, Donnarieix D, Ferrer L, Glick SJ, Groiselle CJ, Guez D, Honore PF, Kerhoas-Cavata S, Kirov AS, Kohli V, Koole M, Krieguer M, van der Laan DJ, Lamare F, Largeron G, Lartizien C, Lazaro D, Maas MC, Maigne L, Mayet F, Melot F, Merheb C, Pennacchio E, Perez J, Pietrzyk U, Rannou FR, Rey M, Schaart DR, Schmidtlein CR, Simon L, Song TY, Vieira JM, Visvikis D, Van de Walle R, Wieërs E, Morel C. GATE: a simulation toolkit for PET and SPECT. Phys Med Biol. 2004;49:4543–61.