Photoacoustic imaging for monitoring of stroke diseases: A review

Photoacoustics - Tập 23 - Trang 100287 - 2021
Xi Yang1,2,3, Yun-Hsuan Chen2,3, Fen Xia1,2,3, Mohamad Sawan2,3
1Zhejiang University, Hangzhou, 310024, Zhejiang, China
2CenBRAIN Lab., School of Engineering, Westlake University, Hangzhou, 310024, Zhejiang, China
3Institute of Advanced Technology, Westlake Institute for Advanced Study, Hangzhou, 310024, Zhejiang, China

Tài liệu tham khảo

Johnson, 2019, Global, regional, and national burden of stroke, 1990–2016: a systematic analysis for the Global Burden of Disease Study 2016, Lancet Neurol., 18, 439, 10.1016/S1474-4422(19)30034-1 Feigin, 2018, Global, regional, and country-specific lifetime risks of stroke, 1990 and 2016, N. Engl. J. Med., 379, 2429, 10.1056/NEJMoa1804492 O’Donnell, 2016, Global and regional effects of potentially modifiable risk factors associated with acute stroke in 32 countries (INTERSTROKE): a case-control study, Lancet, 388, 761, 10.1016/S0140-6736(16)30506-2 Wintermark, 2015, International survey of acute stroke imaging used to make revascularization treatment decisions, Int. J. Stroke, 10, 759, 10.1111/ijs.12491 Carrera, 2017, Imaging-based selection of patients for acute stroke treatment, Neurology, 88, 2242, 10.1212/WNL.0000000000004051 Peultier, 2019, What stroke image do we want? European survey on acute stroke imaging and revascularisation treatment, Health Policy Technol., 8, 261, 10.1016/j.hlpt.2019.08.005 Banerjee, 2017, Stroke caused by atherosclerosis of the major intracranial arteries, Circ. Res., 120, 502, 10.1161/CIRCRESAHA.116.308441 Jordan, 2009, The importance of cerebral aneurysms in childhood hemorrhagic stroke: a population-based study, Stroke, 40, 400, 10.1161/STROKEAHA.108.518761 Gross, 2013, Natural history of cerebral arteriovenous malformations: a meta-analysis, J. Neurosurg., 118, 437, 10.3171/2012.10.JNS121280 Ganzer, 2016, Transient ischemic attack and cognitive impairment: a review, J. Neurosci. Nurs., 48, 322, 10.1097/JNN.0000000000000236 Oliveira, 2019, Headaches attributed to ischemic stroke and transient ischemic attack, Headache J. Head Face Pain, 59, 469, 10.1111/head.13478 Russo, 2016, Combined SPECT/CT and PET/CT for breast imaging, nuclear instruments and methods in physics research section a: accelerators, spectrometers, Detec. Assoc. Equip., 809, 58, 10.1016/j.nima.2015.10.071 Golan, 2019, Imaging-based predictors for hyperbaric oxygen therapy outcome in post-stroke patients. Report 1, Med. Hypotheses, 136 Lloyd-Fox, 2010, Illuminating the developing brain: the past, present and future of functional near infrared spectroscopy, Neurosci. Biobehav. Rev., 34, 269, 10.1016/j.neubiorev.2009.07.008 Chen, 2016, Imaging hemodynamic response after ischemic stroke in mouse cortex using visible-light optical coherence tomography, Biomed. Opt. Express, 7, 3377, 10.1364/BOE.7.003377 Wolf, 2017, The use of routine EEG in acute ischemic stroke patients without seizures: generalized but not focal EEG pathology is associated with clinical deterioration, Int. J. Neurosci., 127, 421, 10.1080/00207454.2016.1189913 Saita, 2018, Biofeedback effect of hybrid assistive limb in stroke rehabilitation: a proof of concept study using functional near infrared spectroscopy, PLoS One, 13, 10.1371/journal.pone.0191361 Sangha, 2016, Photoacoustic tomography: applications for atherosclerosis imaging, J. Opt., 18, 10.1088/2040-8978/18/8/084005 Shrestha, 2020, Photoacoustic imaging in tissue engineering and regenerative medicine, Tissue Eng. Part B Rev., 26, 79, 10.1089/ten.teb.2019.0296 Sangani, 2015, Cortical mechanisms underlying sensorimotor enhancement promoted by walking with haptic inputs in a virtual environment, Prog. Brain Res., 218, 313, 10.1016/bs.pbr.2014.12.003 Burle, 2015, Spatial and temporal resolutions of EEG: is it really black and white? A scalp current density view, Int. J. Psychophysiol., 97, 210, 10.1016/j.ijpsycho.2015.05.004 Lihong V, 2007 Nyayapathi, 2019, Photoacoustic imaging of breast cancer: a mini review of system design and image features, J. Biomed. Opt., 24, 1, 10.1117/1.JBO.24.12.121911 Yao, 2016, Multiscale photoacoustic tomography using reversibly switchable bacterial phytochrome as a near-infrared photochromic probe, Nat. Methods, 13, 67, 10.1038/nmeth.3656 Mukaddim, 2018, Real-time in vivo photoacoustic imaging in the assessment of myocardial dynamics in murine model of myocardial ischemia, Ultrasound Med. Biol., 44, 2155, 10.1016/j.ultrasmedbio.2018.05.021 Cao, 2019, Photoacoustic microscopy of cerebral hemodynamic and metabolic responses to General anesthetics, 215 Jawad, 2018, Dynamic blood flow phantom with negative and positive photoacoustic contrasts, Biomed. Opt. Express, 9, 4702, 10.1364/BOE.9.004702 Sinnamon, 2019, Multispectral photoacoustic imaging for the detection of subclinical melanoma, J. Surg. Oncol., 119, 1070, 10.1002/jso.25447 Wang, 2016, Toward in vivo biopsy of melanoma based on photoacoustic and ultrasound dual imaging with an integrated detector, Biomed. Opt. Express, 7, 279, 10.1364/BOE.7.000279 Jansen, 2011, Intravascular photoacoustic imaging of human coronary atherosclerosis, Opt. Lett., 36, 597, 10.1364/OL.36.000597 Sangha, 2017, In vivo photoacoustic lipid imaging in mice using the second near-infrared window, Biomed. Opt. Express, 8, 736, 10.1364/BOE.8.000736 Cao, 2017, Spectral analysis assisted photoacoustic imaging for lipid composition differentiation, Photoacoustics, 7, 12, 10.1016/j.pacs.2017.05.002 Pleitez, 2019, Label-free metabolic imaging by mid-infrared optoacoustic microscopy in living cells, Nat. Biotechnol., 38, 293, 10.1038/s41587-019-0359-9 Yao, 2010, In vivo label-free photoacoustic microscopy of cell nuclei by excitation of DNA and RNA, Opt. Lett., 35, 4139, 10.1364/OL.35.004139 Yao, 2012, Optimal ultraviolet wavelength for in vivo photoacoustic imaging of cell nuclei, J. Biomed. Opt., 17, 10.1117/1.JBO.17.5.056004 Yao, 2013, Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo, NeuroImage, 64, 257, 10.1016/j.neuroimage.2012.08.054 Xia, 2014, Photoacoustic tomography: principles and advances, Electromagn. Waves Camb. (Camb), 147, 1, 10.2528/PIER14032303 Wang, 2013, Single-cell label-free photoacoustic flowoxigraphy in vivo, Proc. Natl. Acad. Sci. U.S.A., 110, 5759, 10.1073/pnas.1215578110 Yao, 2015, High-speed label-free functional photoacoustic microscopy of mouse brain in action, Nat. Methods, 12, 407, 10.1038/nmeth.3336 Zhou, 2019, Optical-resolution photoacoustic microscopy for monitoring vascular normalization during anti-angiogenic therapy, Photoacoustics, 15, 10.1016/j.pacs.2019.100143 Zhou, 2020, Optical-resolution photoacoustic microscopy with ultrafast dual-wavelength excitation, J. Biophotonics, 13, 10.1002/jbio.201960229 Moothanchery, 2020, Acoustic resolution photoacoustic microscopy based on microelectromechanical systems scanner, J. Biophotonics, 13, 10.1002/jbio.201960127 Stein, 2009, Noninvasive, in vivo imaging of the mouse brain using photoacoustic microscopy, J. Appl. Phys., 105, 10.1063/1.3116134 Lan, 2018, High-speed widefield photoacoustic microscopy of small-animal hemodynamics, Biomed. Opt. Express, 9, 4689, 10.1364/BOE.9.004689 Jeon, 2017, In vivo photoacoustic imaging of anterior ocular vasculature: a random sample consensus approach, Sci. Rep., 7, 4318, 10.1038/s41598-017-04334-z Zhang, 2018, High-resolution, in vivo multimodal photoacoustic microscopy, optical coherence tomography, and fluorescence microscopy imaging of rabbit retinal neovascularization, Light Sci. Appl., 7, 103, 10.1038/s41377-018-0093-y Liu, 2015, Optical coherence photoacoustic microscopy for in vivo multimodal retinal imaging, Opt. Lett., 40, 1370, 10.1364/OL.40.001370 Wu, 2014, High-resolution dual-modality photoacoustic ocular imaging, Opt. Lett., 39, 2451, 10.1364/OL.39.002451 Hu, 2011, Second-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed, Opt. Lett., 36, 1134, 10.1364/OL.36.001134 Kim, 2019, Super-resolution localization photoacoustic microscopy using intrinsic red blood cells as contrast absorbers, Light Sci. Appl., 8, 103, 10.1038/s41377-019-0220-4 Zhang, 2019, In vivo superresolution photoacoustic computed tomography by localization of single dyed droplets, Light Sci. Appl., 8, 36, 10.1038/s41377-019-0147-9 Liang, 2020, Photoacoustic computed tomography by using a multi-angle scanning fiber-laser ultrasound sensor, Opt. Express, 28, 8744, 10.1364/OE.387675 Li, 2017, Single-impulse panoramic photoacoustic computed tomography of small-animal whole-body dynamics at high spatiotemporal resolution, Nat. Biomed. Eng., 1, 0071, 10.1038/s41551-017-0071 Li, 2020, Snapshot photoacoustic topography through an ergodic relay for high-throughput imaging of optical absorption, Nat. Photonics, 14, 164, 10.1038/s41566-019-0576-2 Li, 2020, Multifocal photoacoustic microscopy using a single-element ultrasonic transducer through an ergodic relay, Light Sci. Appl., 9, 135, 10.1038/s41377-020-00372-x Yao, 2018, Recent progress in photoacoustic molecular imaging, Curr. Opin. Chem. Biol., 45, 104, 10.1016/j.cbpa.2018.03.016 Cao, 2018, Photoacoustic microscopy reveals the hemodynamic basis of sphingosine 1-phosphate-induced neuroprotection against ischemic stroke, Theranostics, 8, 6111, 10.7150/thno.29435 Klibanov, 2019, Monitoring oxygenation levels deep in the tumor core: noninvasive imaging of hypoxia, now in real-time 3D, Cancer Res., 79, 4577, 10.1158/0008-5472.CAN-19-2151 Buchmann, 2016, Evaluation of fabry-perot polymer film sensors made using hard dielectric mirror deposition Alles, 2018, Reconfigurable 1.5D source arrays for improved elevational focussing in all-optical ultrasound imaging, 2018 IEEE International Ultrasonics Symposium (IUS), 1 Maneas, 2018, Human placental vasculature imaging using an LED-based photoacoustic/ultrasound imaging system Esenaliev, 2019, 25 years of biomedical optoacoustics: from idea to optoacoustic imaging and theranostics Ranjbar Taklimie, 2019, Hypoxia induces astrocyte-derived Lipocalin-2 in ischemic stroke, Int. J. Mol. Sci., 20, 1271, 10.3390/ijms20061271 Ferdinand, 2016, Hypoxia after stroke: a review of experimental and clinical evidence, Exp. Transl. Stroke Med., 8, 9, 10.1186/s13231-016-0023-0 Kneipp, 2014, Real-time optoacoustic monitoring of stroke Ringuette, 2018, Multi-spectral photoacoustic tracking of non-invasive photothrombotic ischemic stroke Ning, 2016, Multi-parametric photoacoustic microscopy of photothrombotic stroke in the mouse brain Lin, 2017, High-speed photoacoustic microscopy of mouse cortical microhemodynamics, J. Biophotonics, 10, 792, 10.1002/jbio.201600236 Molina, 2011, Reperfusion therapies for acute ischemic stroke: current pharmacological and mechanical approaches, Stroke, 42, S16 Clifton, 2017, Mechanical thrombectomy services: can the UK meet the challenge?, Pract. Neurol., 17, 250, 10.1136/practneurol-2017-001692 Liu, 2017, Integrated treatment modality of cathodal-transcranial direct current stimulation with peripheral sensory stimulation affords neuroprotection in a rat stroke model, Neurophotonics, 4, 10.1117/1.NPh.4.4.045002 Sussman, 2012, Photoacoustic tomography can detect cerebral hemodynamic alterations in a neonatal rodent model of hypoxia-ischemia, Acta Neurobiol. Exp. (Wars), 72, 253 Kang, 2018, Validation of noninvasive photoacoustic measurements of sagittal sinus oxyhemoglobin saturation in hypoxic neonatal piglets, J. Appl. Physiol., 125, 983, 10.1152/japplphysiol.00184.2018 Rajendran, 2020, In vivo detection of venous sinus distension due to intracranial hypotension in small animal using pulsed-laser-diode photoacoustic tomography, J. Biophotonics, 13, 10.1002/jbio.201960162 Dreier, 2011, The role of spreading depression, spreading depolarization and spreading ischemia in neurological disease, Nat. Med., 17, 439, 10.1038/nm.2333 Garcia-Uribe, 2015, Dual-modality photoacoustic and ultrasound imaging system for noninvasive sentinel lymph node detection in patients with breast Cancer, Sci. Rep., 5, 15748, 10.1038/srep15748 Dreier, 2006, Delayed ischaemic neurological deficits after subarachnoid haemorrhage are associated with clusters of spreading depolarizations, Brain, 129, 3224, 10.1093/brain/awl297 Helbok, 2017, Clinical use of cerebral microdialysis in patients with aneurysmal subarachnoid hemorrhage-state of the art, Front. Neurol., 8, 565, 10.3389/fneur.2017.00565 Santos, 2017, Heterogeneous propagation of spreading depolarizations in the lissencephalic and gyrencephalic brain, J. Cereb. Blood Flow. Metab., 37, 2639, 10.1177/0271678X16689801 Santos, 2014, Radial, spiral and reverberating waves of spreading depolarization occur in the gyrencephalic brain, NeuroImage, 99, 244, 10.1016/j.neuroimage.2014.05.021 Kirchner, 2019, Photoacoustics can image spreading depolarization deep in gyrencephalic brain, Sci. Rep., 9, 8661, 10.1038/s41598-019-44935-4 Lv, 2020, In vivo photoacoustic imaging dynamically monitors the structural and functional changes of ischemic stroke at a very early stage, Theranostics, 10, 816, 10.7150/thno.38554 Wu, 2019, In vivo hemodynamic visualization of berberine-induced effect on the cerebral cortex of a mouse by photoacoustic tomography, Appl. Opt., 58, 1, 10.1364/AO.58.000001 Ni, 2018, Non-invasive detection of matrix-metalloproteinase activity in a mouse model of cerebral ischemia using multispectral optoacoustic tomography Ni, 2018, Noninvasive detection of acute cerebral hypoxia and subsequent matrix-metalloproteinase activity in a mouse model of cerebral ischemia using multispectral-optoacoustic-tomography, Neurophotonics, 5, 10.1117/1.NPh.5.1.015005 Yang, 2017, Intracerebral haemorrhage-induced injury progression assessed by cross-sectional photoacoustic tomography, Biomed. Opt. Express, 8, 5814, 10.1364/BOE.8.005814 Wu, 2017, Noninvasive in vivo monitoring of collagenase induced intracerebral hemorrhage by photoacoustic tomography, Biomed. Opt. Express, 8, 2276, 10.1364/BOE.8.002276 Kneipp, 2014, Functional real-time optoacoustic imaging of middle cerebral artery occlusion in mice, PLoS One, 9, 10.1371/journal.pone.0096118 Liao, 2013, Study of neurovascular coupling functions for transient focal cerebral ischemia in rats using electrocorticography functional photoacoustic microscopy (ECoG-fPAM), 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 1799, 10.1109/EMBC.2013.6609871 Hu, 2011, Optical-resolution photoacoustic microscopy of ischemic stroke Zafar, 2018, Photoacoustic cardiovascular imaging: a new technique for imaging of atherosclerosis and vulnerable plaque detection, Biomed. Phys. Eng. Express, 4, 10.1088/2057-1976/aab640 Lockwood, 2017 Juratli, 2018, Noninvasive label-free detection of circulating white and red blood clots in deep vessels with a focused photoacoustic probe, Biomed. Opt. Express, 9, 5667, 10.1364/BOE.9.005667 Hsu, 2018 Arabul, 2017, Toward the detection of intraplaque hemorrhage in carotid artery lesions using photoacoustic imaging, J. Biomed. Opt., 22, 41010, 10.1117/1.JBO.22.4.041010 Mercep, 2018, Imaging of blood flow and oxygen state with a multi-segment optoacoustic ultrasound array, Photoacoustics, 10, 48, 10.1016/j.pacs.2018.04.002 Wang, 2010, Detection of lipid in atherosclerotic vessels using ultrasound-guided spectroscopic intravascular photoacoustic imaging, Opt. Express, 18, 4889, 10.1364/OE.18.004889 Kruizinga, 2014, Photoacoustic imaging of carotid artery atherosclerosis, J. Biomed. Opt., 19, 10.1117/1.JBO.19.11.110504 Brown, 2019, Photoacoustic imaging as a tool to probe the tumour microenvironment, Dis. Model. Mech., 12, 10.1242/dmm.039636 Hirasawa, 2017, Multispectral photoacoustic imaging of tumours in mice injected with an enzyme-activatable photoacoustic probe, J. Opt., 19, 10.1088/2040-8978/19/1/014002 He, 2016, In vivo label-free photoacoustic flow cytography and on-the-spot laser killing of single circulating melanoma cells, Sci. Rep., 6, 39616, 10.1038/srep39616 Toi, 2017, Visualization of tumor-related blood vessels in human breast by photoacoustic imaging system with a hemispherical detector array, Sci. Rep., 7, 41970, 10.1038/srep41970 Lin, 2018, Single-breath-hold photoacoustic computed tomography of the breast, Nat. Commun., 9, 2352, 10.1038/s41467-018-04576-z Iskander-Rizk, 2019, Photoacoustic imaging for guidance of interventions in cardiovascular medicine, Phys. Med. Biol., 64, 10.1088/1361-6560/ab1ede Saikrishnan, 2014, Accurate assessment of aortic stenosis: a review of diagnostic modalities and hemodynamics, Circulation, 129, 244, 10.1161/CIRCULATIONAHA.113.002310 Cooper, 2015, Components of hemodynamic load and cardiovascular events: the Framingham Heart Study, Circulation, 131, 354, 10.1161/CIRCULATIONAHA.114.011357 Kario, 2017, Development of a new ICT-Based multisensor blood pressure monitoring system for use in hemodynamic biomarker-initiated anticipation medicine for cardiovascular disease: the national IMPACT program project, Prog Cardiovasc Dis, 60, 435, 10.1016/j.pcad.2017.10.002 Zhang, 2018, Effects of exercise modalities on central hemodynamics, arterial stiffness and cardiac function in cardiovascular disease: systematic review and meta-analysis of randomized controlled trials, PLoS One, 13, 10.1371/journal.pone.0200829 Wang, 2019, Congenital heart disease and risk of cardiovascular disease: a meta-analysis of cohort studies, J. Am. Heart Assoc., 8, 10.1161/JAHA.119.012030 Stanaway, 2018, Lancet, 392, 1923, 10.1016/S0140-6736(18)32225-6 Cao, 2019, Photoacoustic microscopy of obesity-induced cerebrovascular alterations, NeuroImage, 188, 369, 10.1016/j.neuroimage.2018.12.027 Wang, 2003, Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain, Nat. Biotechnol., 21, 803, 10.1038/nbt839 Yao, 2014, Photoacoustic brain imaging: from microscopic to macroscopic scales, Neurophotonics, 1, 10.1117/1.NPh.1.1.011003 Nie, 2011, Photoacoustic tomography of monkey brain using virtual point ultrasonic transducers, J. Biomed. Opt., 16, 10.1117/1.3595842 Yang, 2008, Monkey brain cortex imaging by photoacoustic tomography, J. Biomed. Opt., 13, 10.1117/1.2967907 Jo, 2012, Photoacoustic detection of functional responses in the motor cortex of awake behaving monkey during forelimb movement, J. Biomed. Opt., 17, 10.1117/1.JBO.17.11.110503 Petrov, 2012, Optoacoustic monitoring of cerebral venous blood oxygenation though intact scalp in large animals, Opt. Express, 20, 4159, 10.1364/OE.20.004159 MacCuaig, 2020, Development of multispectral optoacoustic tomography as a clinically translatable modality for Cancer imaging, Radiol. Imaging Cancer, 2, 10.1148/rycan.2020200066 Na, 2021, Massively parallel functional photoacoustic computed tomography of the human brain, Nat. Biomed. Eng., 10.1038/s41551-021-00735-8 Nie, 2012, Photoacoustic tomography through a whole adult human skull with a photon recycler, J. Biomed. Opt., 17, 10.1117/1.JBO.17.11.110506 Zhou, 2014, Handheld photoacoustic microscopy to detect melanoma depth in vivo, Opt. Lett., 39, 4731, 10.1364/OL.39.004731 Huynh, 2016, Photoacoustic imaging using an 8-beam Fabry-Perot scanner Ellwood, 2017, Photoacoustic tomography using orthogonal Fabry-Perot sensors, J. Biomed. Opt., 22, 10.1117/1.JBO.22.4.041009 Schellenberg, 2018, Hand-held optoacoustic imaging: a review, Photoacoustics, 11, 14, 10.1016/j.pacs.2018.07.001 Dean-Ben, 2014, Universal hand-held three-dimensional optoacoustic imaging probe for deep tissue human angiography and functional preclinical studies in real time, J. Vis. Exp., 93 Kassab, 2015, Functional near-infrared spectroscopy caps for brain activity monitoring: a review, Appl. Opt., 54, 576, 10.1364/AO.54.000576 Dangi, 2020, A modular approach to neonatal whole-brain photoacoustic imaging Tavakolian, 2013, Potential for photoacoustic imaging of the neonatal brain Bai, 2014, Intravascular optical-resolution photoacoustic tomography with a 1.1 mm diameter catheter, PLoS One, 9, 10.1371/journal.pone.0092463 Wen, 2020, High-robustness intravascular photoacoustic endoscope with a hermetically sealed opto-sono capsule, Opt. Express, 28, 19255, 10.1364/OE.394781 Tavakoli, 2014, Detecting occlusion inside a ventricular catheter using photoacoustic imaging through skull Olefir, 2016, Hybrid multispectral optoacoustic and ultrasound tomography for morphological and physiological brain imaging, J. Biomed. Opt., 21, 86005, 10.1117/1.JBO.21.8.086005 Xi, 2017, Hybrid photoacoustic and electrophysiological recording of neurovascular communications in freely-moving rats, NeuroImage, 161, 232, 10.1016/j.neuroimage.2017.08.037 Liu, 2015, Assessment of neurovascular dynamics during transient ischemic attack by the novel integration of micro-electrocorticography electrode array with functional photoacoustic microscopy, Neurobiol. Dis., 82, 455, 10.1016/j.nbd.2015.06.019 Wang, 2014, Simultaneous real-time 3D photoacoustic tomography and EEG for neurovascular coupling study in an animal model of epilepsy, J. Neural. Eng., 11, 10.1088/1741-2560/11/4/046013 Huang, 2012, Aberration correction for transcranial photoacoustic tomography of primates employing adjunct image data, J. Biomed. Opt., 17, 10.1117/1.JBO.17.6.066016 Johnstonbaugh, 2020, A deep learning approach to photoacoustic wavefront localization in deep-tissue medium, IEEE Trans. Ultrason., Ferroelectr., Freq., Control, 67, 2649, 10.1109/TUFFC.2020.2964698 Song, 2020, Analysis of the influence of skull on photon transmission based on Monte Carlo method, Proc. SPIE 11717, 24th National Laser Conference & Fifteenth National Conference on Laser Technology and Optoelectronics, 10.1117/12.2587197 Teng, 2020, Simulation study of interaction of pulse laser with brain using COMSOL Mohammadi, 2019, Skull’s photoacoustic attenuation and dispersion modeling with deterministic ray-tracing: towards real-time aberration correction, Sensors, 19, 10.3390/s19020345 Poudel, 2020, Iterative image reconstruction in transcranial photoacoustic tomography based on the elastic wave equation, Phys. Med. Biol., 65, 10.1088/1361-6560/ab6b46 Na, 2020, Transcranial photoacoustic computed tomography based on a layered back-projection method, Photoacoustics, 20, 10.1016/j.pacs.2020.100213 Mohammadi, 2020, Skull acoustic aberration correction in photoacoustic microscopy using a vector space similarity model: a proof-of-concept simulation study, Biomed. Opt. Express, 11, 5542, 10.1364/BOE.402027 Bucking, 2017, From medical imaging data to 3D printed anatomical models, PLoS One, 12, 10.1371/journal.pone.0178540 Kim, 2020, Deep-learning image reconstruction for real-time photoacoustic system, IEEE Trans. Med. Imaging, 39, 3379, 10.1109/TMI.2020.2993835 Lan, 2019, Reconstruct the photoacoustic image based on deep learning with multi-frequency ring-shape transducer array, 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 7115 Manwar, 2020, Deep learning protocol for improved photoacoustic brain imaging, J. Biophotonics, 13, 10.1002/jbio.202000212 Karlas, 2019, Cardiovascular optoacoustics: from mice to men - A review, Photoacoustics, 14, 19, 10.1016/j.pacs.2019.03.001 Dangi, 2020, Towards a low-cost and portable photoacoustic microscope for point-of-care and wearable applications, IEEE Sens J., 20, 6881, 10.1109/JSEN.2019.2935684 Ansari, 2020, Miniature all-optical flexible forward-viewing photoacoustic endoscopy probe for surgical guidance, Opt. Lett., 45, 6238, 10.1364/OL.400295 Yokota, 2021, Recent progress of flexible image sensors for biomedical applications, Adv. Mater., 10.1002/adma.202004416 Kuriakose, 2020, Optimizing irradiation geometry in LED-based photoacoustic imaging with 3D printed flexible and modular light delivery system, Sensors, 20, 10.3390/s20133789 Chen, 2021, Trends and challenges of wearable multimodal technologies for stroke risk prediction, Sensors, 21, 460, 10.3390/s21020460