Performance of selected lightweight wheelchairs on ANSI/RESNA tests
Tài liệu tham khảo
Marlowe, 1988, Assessing wheelchair performance: the role of regulations and standards, 61
Cooper, 1991, High-tech wheelchairs gain the competitive edge, IEEE Eng Med Biol Mag, 10, 49, 10.1109/51.107169
Axelson, 1994
McLaurin, 1986, Wheelchair development, standards, progress, and issues: a discussion with Colin McLaurin, J Rehabil Res Dev, 23, 48
Cooper, 1995
McLaurin, 1990, Wheelchair standards: an overview, choosing a wheelchair system, J Rehabil Res Dev, 2, 100
Axelson, 1994, Chairs, chairs, everywhere!, Sports'n Spokes, 19, 15
Axelson, 1993, Wheelchair comparison, Sports'n Spokes, 18, 34
Axelson, 1994, Lightweight Choice, Mainstream, 18, 22
McFarland, 1990, Seeking information about wheelchair evaluation: a call for action, choosing a wheelchair system, J Rehabil Res Dev, 10, 86
Bryant, 1991, Wheelchair standards ready to roll, Team Rehab Report, 44
Pronsati, 1991, Standardization will bring better products to wheelchair consumers, Advance for Physical Therapists, 2, 22
Axelson, 1992, Wheelchair standards and you, Paraplegia News, 46, 54
Horn, 1991, U.S. committee adopts wheelchair standards, Phys Ther Bull, 6, 4
Horn, 1991, U.S. committee adopts wheelchair standards, Phys Ther Bull, 6, 34
Tam, 1992, Using ISO standards for manual wheelchair testing: the Hong Kong experience, 625
Roebroeck, 1987, Methodology of consumer evaluation of hand propelled wheelchairs
Johnson, 1991, European report on wheelchair testing
Baldwin, 1993, Characterization of the dynamic stress response of manual and powered wheelchair frames, J Rehabil Res Dev, 30, 224
Cooper, 1994, Manual wheelchair ISO-ANSI/RESNA fatigue testing experience, 324
Vansickle, 1996, Determination of wheelchair dynamic load data for use with finite element analysis, IEEE Trans Rehabil Eng, 4, 161, 10.1109/86.536771
Barnicle, 1993
Cooper, 1996, Life-cycle analysis of depot versus rehabilitation manual wheelchairs, J Rehabil Res Dev, 33, 45
Cooper, 1991, Development of a new ISO wheelchair two-drum tester, 1867
International, 1994, Wheelchairs—Part 8: requirements and test methods for static, impact, and fatigue strength
Cooper, 1992, An improved design of a 100 kilogram ISO/RESNA wheelchair test dummy, 210
Cooper, 1993, Design of an anthropomorphic ISO-RESNA/ANSI wheelchair test dummy, 283
Cooper, 1994, Evaluation of methods for determining rearward static stability of manual wheelchairs, J Rehabil Res Dev, 31, 144
Cooper, 1994, Wheelchair impact response to ISO test pendulum and ISO standard curb, IEEE Trans Rehabil Eng, 2, 240, 10.1109/86.340874
Cooper, 1993, Stability of a wheelchair controlled by a human pilot, IEEE Trans Rehabil Eng, 1, 193, 10.1109/86.285732
Kirby, 1994, Wheelchair-related accidents caused by tips and falls among noninstitutionalized users of manually propelled wheelchairs in Nova Scotia, Am J Phys Med Rehabil, 73, 319, 10.1097/00002060-199409000-00004
Unmat, 1994, Nonfatal wheelchair-related accidents reported to the national electronic injury surveillance system, Am J Phys Med Rehabil, 73, 163, 10.1097/00002060-199406000-00004
Szeto, 1983, Evaluation of a curb-climbing aid for manual wheelchairs: considerations of safety, effort, and stability, J Rehabil Res Dev, 20, 45
Majaess, 1993, Influence of seat position on the static and dynamic forward and rear stability of occupied wheelchairs, Arch Phys Med Rehabil, 74, 977