Performance evaluation of non-intrusive luminance mapping towards human-centered daylighting control

Building and Environment - Tập 213 - Trang 108857 - 2022
Michael Kim1,2, Athanasios Tzempelikos1,2
1Lyles School of Civil Engineering, Purdue University, 550 Stadium Mall Dr., West Lafayette, IN 47907, USA
2Center for High Performance Buildings, Ray W. Herrick Laboratories, Purdue University, 140 S. Martin Jischke Dr., West Lafayette, IN, 47907, USA

Tài liệu tham khảo

Aries, 2015, Daylight and health: a review of the evidence and consequences for the built environment, Light. Res. Technol., 47, 6, 10.1177/1477153513509258 Borisuit, 2013, The impact of light including non-image forming effects on visual comfort, École Polytechnique Fédérale De Lausanne, 6007 Boyce, 2014, Human factors in lighting Figueiro, 2018, Non-visual effects of light: how to use light to promote circadian entrainment and elicit alertness, Light. Res. Technol., 50, 38, 10.1177/1477153517721598 Galasiu, 2006, Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature review, Energy Build., 38, 728, 10.1016/j.enbuild.2006.03.001 Konis, 2017, A novel circadian daylight metric for building design and evaluation, Build. Environ., 113, 22, 10.1016/j.buildenv.2016.11.025 Münch, 2020, The role of daylight for humans: gaps in current knowledge, Clocks & Sleep, 2, 61, 10.3390/clockssleep2010008 Hamedani, 2020, Revealing the relationships between luminous environment characteristics and physiological, ocular and performance measures: an experimental study, Build. Environ., 172, 106702, 10.1016/j.buildenv.2020.106702 Konstantzos, 2020, The effect of lighting environment on task performance in buildings – a review, Energy Build., 226, 110394, 10.1016/j.enbuild.2020.110394 van Bommel, 2004, Lighting for work: a review of visual and biological effects, Light. Res. Technol., 36, 255, 10.1191/1365782804li122oa Carlucci, 2015, A review of indices for assessing visual comfort with a view to their use in optimization processes to support building integrated design, Renew. Sustain. Energy Rev., 47, 1016, 10.1016/j.rser.2015.03.062 Xiong, 2019, A personalized daylighting control approach to dynamically optimize visual satisfaction and lighting energy use, Energy Build., 193, 111, 10.1016/j.enbuild.2019.03.046 Amundadottir, 2017, A human-centric approach to assess daylight in buildings for non-visual health potential, visual interest and gaze behavior, Build. Environ., 113, 5, 10.1016/j.buildenv.2016.09.033 van den Wymelenberg, 2014, A critical investigation of common lighting design metrics for predicting human visual comfort in offices with daylight, LEUKOS J. Illum. Eng. Soc. North Am., 10, 145 Cuttle, 2004, Brightness, lightness, and providing “a preconceived appearance to the interior, Light. Res. Technol., 36, 201, 10.1191/1365782804li115oa Kruisselbrink, 2018, Photometric measurements of lighting quality: an overview, Build. Environ., 138, 42, 10.1016/j.buildenv.2018.04.028 Marty, 2003 Ware, 2013, Lightness, brightness, contrast, and constancy, 69 Inanici, 2006, Evaluation of high dynamic range photography as a luminance data acquisition system, Light. Res. Technol., 38, 123, 10.1191/1365782806li164oa Moeck, 2007, Accuracy of luminance maps obtained from high dynamic range images, LEUKOS J. Illum. Eng. Soc. North Am., 4, 99 Tyukhova, 2014, An assessment of high dynamic range luminance measurements with LED lighting, LEUKOS J. Illum. Eng. Soc. North Am., 10, 87 Cauwerts, 2018, Application of high-dynamic range imaging techniques in architecture: a step toward high-quality daylit interiors?, J. Imag., 4 Fan, 2009, A data collection method for long-term field studies of visual comfort in real-world daylit office environments Pierson, 2019 Wagdy, 2019, A parametric method for remapping and calibrating fisheye images for glare analysis, Buildings, 9, 1, 10.3390/buildings9100219 Hirning, 2014, Discomfort glare in open plan green buildings, Energy Build., 70, 427, 10.1016/j.enbuild.2013.11.053 Konstantzos, 2017, Daylight glare evaluation with the sun in the field of view through window shades, Build. Environ., 113, 65, 10.1016/j.buildenv.2016.09.009 Suk, 2013, Development of new daylight glare analysis methodology using absolute glare factor and relative glare factor, Energy Build., 64, 113, 10.1016/j.enbuild.2013.04.020 Wagdy, 2017, 3 Wienold, 2006, Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras, Energy Build., 38, 743, 10.1016/j.enbuild.2006.03.017 Yamin Garreton, 2018, A global evaluation of discomfort glare metrics in real office spaces with presence of direct sunlight, Energy Build., 166, 145, 10.1016/j.enbuild.2018.01.024 Tzempelikos, 2017, Advances on daylighting and visual comfort research, Build. Environ., 113, 1, 10.1016/j.buildenv.2016.12.002 Wienold, 2019, Cross-validation and robustness of daylight glare metrics, Light. Res. Technol., 51, 983, 10.1177/1477153519826003 Suk, 2017, Investigation of existing discomfort glare indices using human subject study data, Build. Environ., 113, 121, 10.1016/j.buildenv.2016.09.018 Kruisselbrink, 2017, A practical device for measuring the luminance distribution, Int. J. Sustain. Light., 19, 75, 10.26607/ijsl.v19i1.76 Wu, 2019, Design and validation of a compact embedded photometric device for real-time daylighting computing in office buildings, Build. Environ., 148, 309, 10.1016/j.buildenv.2018.11.016 Goovaerts, 2017, Shading control strategy to avoid visual discomfort by using a low-cost camera: a field study of two cases, Build. Environ., 125, 26, 10.1016/j.buildenv.2017.08.030 Motamed, 2017, On-site monitoring and subjective comfort assessment of a sun shadings and electric lighting controller based on novel High Dynamic Range vision sensors, Energy Build., 149, 58, 10.1016/j.enbuild.2017.05.017 Kim, 2019, A low-cost stereo-fisheye camera sensor for daylighting and glare control, J. Phys. Conf., 1343, 10.1088/1742-6596/1343/1/012157 Kim, 2020, Real-time daylight glare control using a low-cost, window-mounted HDRI sensor, Build. Environ., 177, 106912, 10.1016/j.buildenv.2020.106912 Adam, 2019, Embedded microcontroller with a CCD camera as a digital lighting control system, Electronics, 8, 33, 10.3390/electronics8010033 Doulos, 2013, Reviewing drawbacks of conventional photosensors: are ccd/cmos sensors the next generation? Kruisselbrink, 2020, Feasibility of ceiling-based luminance distribution measurements, Build. Environ., 172, 106699, 10.1016/j.buildenv.2020.106699 Kruisselbrink, 2020, A comparative study between two algorithms for luminance-based lighting control, Energy Build., 228, 10.1016/j.enbuild.2020.110429 Konis, 2014, Predicting visual comfort in side-lit open-plan core zones: results of a field study pairing high dynamic range images with subjective responses, Energy Build., 77, 67, 10.1016/j.enbuild.2014.03.035 Motamed, 2015, 235 Motamed, 2020, Self-commissioning glare-based control system for integrated Venetian blind and electric lighting, Build. Environ., 171, 106642, 10.1016/j.buildenv.2019.106642 Songwa Prince Kim, 2021, Semi-automated luminance map re-projection via high dynamic range imaging and indoor space 3-D reconstruction, Autom. ConStruct., 129, 103812, 10.1016/j.autcon.2021.103812 Schönberger, 2016, Structure-from-Motion revisited, 4104 OpenMVS, 2020, OpenMVS: open Multi-View Stereo reconstruction library Zhou, 2018 Shen, 2017, Daylight-linked synchronized shading operation using simplified model-based control, Energy Build., 145, 200, 10.1016/j.enbuild.2017.04.021 Wienold, 2002, 2 Wang, 2004, Image quality assessment: from error visibility to structural similarity, IEEE Trans. Image Process., 13, 10.1109/TIP.2003.819861 Wang, 2004, Image quality assessment: from error visibility to structural similarity, IEEE Trans. Image Process., 13, 600, 10.1109/TIP.2003.819861 Jakubiec, 2012, The ’adaptive zone’-A concept for assessing discomfort glare throughout daylit spaces, Light. Res. Technol., 44, 149, 10.1177/1477153511420097 Wienold, 2007, Dynamic simulation of blind control strategies for visual comfort and energy balance analysis, 1197 Rodriguez, 2016 Hosmer, 2013 Konstantzos, 2015, Experimental and simulation analysis of daylight glare probability inoffices with dynamic window shades, Build. Environ., 87, 244, 10.1016/j.buildenv.2015.02.007 Kumaragurubaran, 2013, Hdrscope: high dynamic range image processing toolkit for lighting simulations and analysis